首页资源分类其它科学普及 > Compact fans 紧凑型风机_2014_EN

Compact fans 紧凑型风机_2014_EN

已有 454926个资源

下载专区

上传者其他资源

文档信息举报收藏

标    签: 风机风扇

分    享:

文档简介

Compact fans 紧凑型风机_2014_EN

文档预览

Compact fans for AC and DC version 2014 Trendsetter in fan technology Uncompromising quality made by ebm-papst Among the best. Trendsetting with innovative technologies. Listening to customers’ needs. Developing new ideas to meet requirements and realising them with pioneering spirit. This philosophy has made ebm-papst the technological leader in the world of fans. A brand which has very little real competition because every fan is a product of decades of application expertise gained from large-volume production and because we are in a position to produce highly efficient quality products. Our intelligent solutions for electronics cooling ensure that you are one step ahead of competitors thanks to innovative, reliable top-quality technology which is cost-favourable and in line with market requirements. And if required, tailor-made right down to the last detail. In other words, if you need fans which do not yet actually exist, contact us. Insist on ebm-papst. 2 Information DC axial fans DC centrifugal fans Table of contents Information – The company – GreenTech: The Green Company – Expertise and technology – Tailor-made – Optional special designs – Types of fans – Selecting the correct fan – Fan installation – Service life – Definitions – Type code DC axial fans – Axial fans DC centrifugal fans – Centrifugal fans – Tangential blowers – Centrifugal fans and blowers ACmaxx / GreenTech EC-Compact fans 179 4 – Axial fans 184 6 8 AC axial fans 201 10 – Axial fans 204 12 13 AC centrifugal fans 227 14 – Centrifugal fans 230 15 17 Accessories 237 18 – Guard grilles 238 19 – Filter guard grilles 246 – Inlet nozzles 248 25 – Connection cables 251 31 – Handheld programmer 252 – Accessories 253 89 – Electrical connections 254 93 134 ebm-papst representatives & subsidiaries 260 136 DC fans - specials 161 – Speed signal 164 – Alarm signal 168 – Vario-Pro® 173 – Speed setting 174 – Protected fans, Type of protection: IP 54 / IP 68 177 DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Representatives 3 Company profile: ebm-papst The entire scope of ventilation and drive technology: this is the world of ebm-papst. More than 11.000 people – in Germany and throughout the world – develop, produce and sell our motors and fans. Our global presence and our unique range of products based on a quality standard that surpasses every other have made us what we are: world market leader in motors and fans. Expertly knowing what our customers need and incessantly striving to arrive at the perfect application solution for a wide variety of different industries is what determines our daily work. Those who know us know the high standards we apply to our work and know our creed: to be as close to our customers as possible and to simply be the best in terms of innovation and reliability. 4 Information DC axial fans DC centrifugal fans DC fans - specials Our history – Our drive Rooted in ebm, PAPST and mvl, the three leading innovators in the development and production of motors and fans, ebm-papst has established itself as the world market leader. Now as ever, our legendary inventive spirit shines through in products that set standards in many segments of industry worldwide. We are proud to say that despite difficult competition, our performance has always been exemplary and outstanding – in business, in our personal relationship with our customers, and of course with respect to technology and engineering. For decades, we have contributed to the world of air technology and drive engineering with small revolutions and large milestones. To maintain this advantage in skills and knowledge to get maximum quality and thus the highest degree of customer satisfaction, our employees around the world put their passion and dedication to work for you. Passionately involved in R&D Our catalogues just list the results of our incessant efforts in R&D: products of highest quality and reliability. After all, it is our passion to constantly try something new and improve what we have. In doing so, we take advantage of the latest development methods and state-ofthe-art technology and invest quite heavily in R&D facilities. Best of all, though, we rely on excellently trained and skilled engineers and technicians to be at your service in R&D and Sales & Distribution. development, material selection through to picking certified, choice suppliers and on to the production of parts and final delivery. On top of this, our products have to pass the most rigorous tests under all realistic operating conditions: continuous stress test, salt spray test, vibration test, or precision noise measuring, just to mention a few. And the product gets clearance for serial production only after all the desired characteristics have been determined to be just right. Environmental care is another priority with ebm-papst. This is why we have developed our product line in EC technology, which makes for very low power consumption. Due to our manufacturing philosophy, there is absolute focus on environmental care in production, recycling, waste and wastewater disposal. Global Domestic In order to be specialist for customised solutions throughout the world, you need strong partners. Global Domestic – i.e. being present all over the world and being a national company in each individual country – is how we have established ourselves in all important markets on this globe with our successful subsidiaries. And so you will always find ebm-papst close to home, speaking your language, and knowing the demands of your markets. Besides, our worldwide production alliance serves as a basis for competitive pricing. Our global services and logistic outlets, i.e. IT networking, safeguard short reaction times and just-in-time delivery. Producing and safeguarding high-quality products and services This is our promise without any compromise. Whether produced in one of our six factories in Germany or one of our eleven international production sites, our products always have the same high level of quality. This quality control is something you can definitely rely on! And this across all levels of production and throughout all processes: consulting customers, All our efforts are documented in a comprehensive quality management system, both for products and services. Being certified as complying with the tough requirements of the international standards DIN EN ISO 9001, ISO/TS 16949-2 and of standard DIN EN ISO 14001 is just one seal of approval we have received for our unceasing efforts to provide only the best quality products and services. ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Representatives 5 Sustainability is at the centre of our thoughts and actions. Out of conviction! Eco-friendliness and sustainability have always been at the core of our thoughts and actions. For decades, we have worked according to the simple but strict creed of our co-founder Gerhard Sturm: “Each new product we develop has to be better than the last one in terms of economy and ecology.” GreenTech is the ultimate expression of our corporate philosophy. GreenTech is pro-active development. Even in the design phase, the materials and processes we use are optimised for the greatest possible eco-friendliness, energy balance and – wherever possible – recyclability. We continually improve the material and performance of our products, as well as the flow and noise characteristics. At the same time, we significantly reduce energy conumption. Close co-operation with universities and scientific institutes and the professorship we endow in the area of power engineering and regenerative energies allows us to profit from the latest research finings in these fields – and at the same time ensure highly qualified young academics. GreenTech is eco-friendly production. GreenTech also stands for maximum energy efficiency in our production processes. There, the intelligent use of industrial waste heat and groundwater cooling, photovoltaics and, of course, our own cooling and ventilation technology are of the utmost importance. Our most modern plant, for instance, consumes 91% less energy than currently specified and required. In this way, our products contribute to protecting the environment, from their origin to their recyclable packaging. GreenTech pays off for our customers. GreenTech follows a firm philosophy. GreenTech is pro-active development. GreenTech is acknowledged and certified. GreenTech is eco-friendly production. 6 Information DC axial fans DC centrifugal fans GreenTech is acknowledged and certified. Every step in our chain of production meets the stringent standards of environmental specialists and the public. This supports our position as Germany‘s most sustainable company 2013, as does the DEKRA Award 2012 we received in the category “Umwelt – Herausforderung Energiewende / Environment – Challenge: Transition to more sustainable energy systems”, to name only a few of a large number of examples. The environmental advantage gained in the performance of the products developed from our GreenTech philosophy can also be measured in the fulfillment of the most stringent energy and environmental standards. In many instances, our products are already well below the thresholds energy legislation will impose a few years from now – several times over. Our customers profit from this every day. The heart of GreenTech is future-oriented EC technology from ebm-papst. The EC technology at the core of our most efficient motors and fans allows efficiency of up to 90%, saves energy at a very high level, significantly extends service life and makes our products maintenance-free. These values pay off not only for the environment, but every cent also pays off for the user! All ebm-papst products – even those for which GreenTech EC technology does not (yet) make sense from an application viewpoint – feature the greatest possible connection of economy and ecology. DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Representatives 7 Expertise and technology Drive expertise For the past 60 years, all conceivable types and applications of drive engineering have played an essential role at ebm-papst. A commitment that is the foundation for the development of optimum drive solutions – regardless of the type of fan and its usage. DC fans are generally equipped with electronically commutated external rotor motors; in order to save as much space as possible, commutation electronic components are integrated in the hub of the fan. Our AC fans are mostly driven by shaded-pole or capacitor motors based on the external rotor principle. In the 3900 and 9900 range of particularly slim fans, internal rotor motors are used. Low-noise performance Our aerodynamically optimised design and high mechanical precision produces outstanding noise properties in series production. So-called “soft” commutation electronics of the DC fans ensure an excellent noise performance. By avoiding steep switching edges when the individual coils are switched, this reduces the structure-borne noise from the motor. Computer-aided measurements and series of analyses performed in a state-of-the-art sound measuring chamber are conducted on each fan model from the very beginning. Long service life The bearing system plays a vital role both in the long life time and quietness of device fans. The SINTEC compact bearing provides most of the device fans with a proven bearing system. Constant low noise during the entire operating time and considerably lower shock sensitivity are the outstanding features of this bearing technology. In addition, with regard to temperature endurance, Sintec compact bearings can be used without problems in most applications. Despite the slightly higher noise and shock sensitivity of ball bearings, this bearing technology should be given preference for fans exposed to extreme thermal and adverse application conditions (e.g. extreme environmental conditions, critical installation position, etc.). The service life data provided in this catalogue is based on extensive service life tests and mathematically / scientifically proven service life calculations. Our product descriptions are continuously updated with all relevant data obtained from long-term tests. 8 Information DC axial fans DC centrifugal fans DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans Streamline: Aerodynamics With the aid of state-of-the-art computer programs, we are able to optimise the fan impellers and the inner shape of the housing. Air output and available motor performance are exactly matched with the size of fan. This guarantees the low noise that is typical for ebm-papst, even at high back pressure. Sturdy construction – in metal or plastic Fans of all-metal construction: Sturdy and resistant. The housing is made of an aluminium alloy whereas the metal surfaces that are subject to corrosion are permanently protected by an impact- and abrasion-resistant electrophoretic baked enamel. This particular version is highly recyclable. Fans with fibreglass-reinforced plastic housing and impeller: Excellent stability and low weight distinguish this highly efficient fan concept. Combinations of metal housing and plastic impeller unite the advantages of both types of design. Product images The dimensioned drawings and product photos that appear in the catalogue are for orientation purposes and may differ in some details from the actual product design. Product liability Motors and fans from ebm-papst are components intended for proper installation. The customer bears responsibility for the overall end product. Safety is included It goes without saying that all ebm-papst fans conform to the approval requirements of the VDE (Association of German Electrical Engineers) and the standards and regulations of UL and CSA. All fans conform to the European Standard EN 60335 or EN 60950 plus those of the UL (Underwriters Laboratories) and CSA (Canadian Standards Association). With few exceptions, our DC fans are designed to meet the requirements of protection class 3 / protection class voltage. AC fans are protection class 1. ebm-papst fans meet the highest requirements of electrical safety. All design variants feature reverse polarity and locked rotor protection. Quality in detail It is in the important details where the motto "made by ebm-papst" comes into its own: Consistent adherence to development and design processes and a targeted commitment to quality along the entire process chain are the foundation for the fans' above-average service life. 100.000 hours and above are now possible. The no-compromise ebm-papst quality assurance spans over all process levels – from the choice of materials and the use of carefully selected, certified suppliers, from the production of parts up to final assembly. These details combine to result in reliable fan products with an above-average service life. ErP guidelines All products with power consumption between 125 W and 500 kW are subject to the European "Energy-related Products Directive" (ErP) for improving energy efficiency, with the first stage coming into force from 2013 and the second as of 2015. Thanks to ground-breaking GreenTech EC technology, all of our fans and motors in these performance classes already exceed the ErP Directive today. AC centrifugal fans Accessories Representatives 9 Tailor-made to meet your special requirements Practice-oriented: Fans – customised and intelligent ebm-papst has always developed customer-specific intelligent fans which meet the exact requirements of the application. We provide a wide range of standard fan types, in many sizes and designs; with intelligent motor features, monitoring and control functions as well as special designs for use under extreme conditions. They are all based on the standard type fans which you will find in this catalogue. Special fan types for your application can be produced in economical batch sizes. Our expert engineers will assist you in selecting the right configuration. 10 Information DC axial fans DC centrifugal fans DC fans - specials ACmaxx / GreenTech EC-Compact fans Innovation at its best: Vario-Pro® with “intelligence inside”. Its programmed intelligence thanks to customer-specifically configured software modules makes the cooling of electronics even more economical and flexible. For example, temperature-dependent speed profiles are possible with a number of freely selectable interpolation points. External speed settings and a variety of combinable alarm and tachometer functions can also be programmed. The digital motor management achieves high control accuracy. Higher type of protection for every type of application ebm-papst provides, on request, many fan series in versions which conform to the requirements of type of protection IP 54 and IP 68: Their stator and all electrical components are fully encapsulated. Stainless steel ball bearings can be used for operation in particularly aggressive media and use under extreme environmental conditions, thus providing additional reliability. Virtually everything is possible Regardless of your cooling and ventilation tasks, we develop the right solution and what is more, the most economical one. Based on the fans listed in this catalogue, well over 4000 different versions are available. Temperature-controlled fans Fans with temperature-controlled speed have particularly quiet cooling characteristics. Thanks to integrated IC technology, they adapt their speed to the current cooling requirements, which results in a drastic reduction of noise in most operating modes. A temperature sensor provides the fan with thermal information: either externally via a single lead or integrated into the hub of the fan. Speed setting via interfaces With a wide range of DC fans with separate control input, ebm-papst provides an alternative to the NTC-controlled types of fans. They are especially suitable for systems and units which already have standard interfaces for varying speed via internal switching and control circuits. The main applications are units which demand load-dependent individual speed profiles or systems with stand-by minimum cooling requirements and varied speed increase at varying power peaks. “Electronic tachometer” thanks to sensor signal Do you wish to be informed about the current fan speed at all times? ebm-papst has fans with an integrated “electronic tachometer” which registers the actual value of the fan speed. Via an integrated sensor, the fan generates speed-dependent signals which can be directly utilised. Depending on the number of poles of the motor, 2, 3 or 6 pulses per revolution are generated. Alarm signal for more safety If your application requires monitored fan operation, in addition to speed monitoring, ebm-papst also provides a multitude of varying alarm signals. Depending on the type of fan in question, the signal is either static, already evaluated or interface-compatible. The alarm signal output provides reliable longterm monitoring and a status signal if critical operating conditions evolve. S-Force The new measure of things! When you need to provide extremely fast, powerful and efficient cooling for electronic components of all kinds, the generation of S-Force high-performance fans finishes first: in air performance, pressure build-up and technology. Extremely efficient drives and optimised aerodynamics form the core technology of the S-Force fans, which we offer in both an axial and brand-new centrifugal model. S-Panther S-Panther power delivered quietly. Wherever there is need for power and reduced noise, fans from the S-Panther range are the right solution. A strong pressure saddle curve at optimum air flow provides the power of a real big cat. AC axial fans AC centrifugal fans Accessories Representatives 11 Optional special versions (see chapter DC fans - specials) In the catalogue, a text box in the upper right corner provides information on the special designs which are technically possible in the fan range. Please note that these special versions are not possible for all voltages and speeds, and not in all combinations.The special versions are designed for specific customers and projects and are not usually available off the shelf. 44 max. m3/h DC axial fans Series 630 60 x 60 x 25 mm – Material: Housing: GRP1) (PBT) – Possible special versions: Fan impeller: GRP1) (PA) (See chapter DC fans - specials) – Direction of air flow: Exhaust via struts - Speed signal – Direction of rotation: Clockwise as seen on rotor - Go / No-go alarm – Connection: Via single strands AWG 22, - Alarm with limit speed TR 64 - External temperature sensor – Highlights: Developed for applications with - PWM control input demanding environmental - Analogue control input requirements - Protection against moisture – Ground: 70 g - Protection against salt spray fog - Type of protection: IP 54 / IP 68 Possible special designs are depicted on the catalogue page. Speed signal /2, /12 The fan uses a separate wire to output information about its speed, and thus about the speed of the rotor. For technical details, please refer to page 164 ff. Go / No-go alarm /37, /39 The fan uses a separate wire to output a static signal when it is stationary, thus providing information about whether or not the rotor is turning. For technical details, please refer to page 171 f. Alarm with limit speed /17, /19 If one of the speeds defined in the fan electronics is not met, the fan conveys via a static signal that the set limit speed has not been met. For technical details, please refer to page 168 ff. External temperature sensor A NTC resistor (negative temperature coefficient) is attached to the fan via a separate wire and the fan changes its speed depending on the temperature on the NTC. For technical details, please refer to page 174. Internal temperature sensor In this case, the NTC is integrated into the fan and the fan changes its speed depending on the temperature at the NTC. For technical details, please refer to page 174. PWM control input The speed of the fan can be changed via a pulse-width-modulated signal. This signal is applied to a specially provided wire. For technical details, please refer to page 175. Analogue control input The speed of the fan can be changed via a control voltage. This control voltage is applied to a specially provided wire. For technical details, please refer to page 175. Multi-option control input The fan has a control input that the user can trigger either using a PWM signal, an analogue signal or a resistor. For technical details, please refer to page 176. Protection against moisture Protection for the fan's electronics against moisture and condensation. For technical details, please refer to page 177. Type of protection IP 54 / IP 68 Protection of motor and PCB board against splashed water and humidity. For technical details, please refer to page. 177. Protection against salt fog Protection of fan against the damaging effects of salt fog. For technical details, please refer to page 177. Direction of rotation On many variants, the direction of rotation can be changed via a control input. 12 Information DC axial fans DC centrifugal fans DC fans - specials ACmaxx / GreenTech EC-Compact fans Types of fans and their function Axial fans: High air flow with medium to relatively high pressure build-up The air flow in axial fans, whose impeller is similar to that of a propeller, is conducted to a great extent parallel to the axis of rotation, in other words in the axial direction. Axial fans with free air delivery at zero static pressure have the lowest power input that rises with increasing back pressure. Axial fans for cooling of electronic equipment are mostly equipped with external housing and an electric motor integrated into the fan hub. This compact design allows space-saving accommodation of all devices; the flange is equipped with mounting holes. Diagonal fans: High flow rate at relatively high pressure build-up At first glance diagonal fans only differ slightly from axial fans. Intake is axial, whereas exhaust is diagonal. Due to the conical shape of the wheel and housing, the air is pressurised more. In direct comparison with axial fans of the same size and comparable performance, these fans are distinguished by the lower operating noise at high pressures. Centrifugal fans: High pressure build-up at limited flow rate Many of the cooling problems that occur can be optimally solved by axial and/or diagonal fans. If, for example, the required cooling air has to be conducted at an angle of 90° or if even high pressure is necessary, centrifugal fans are more effective. For your application, ebm-papst offers not only complete centrifugal fans but also motor/impeller combinations without external housing. Tangential fans: High flow rate at low pressure Tangential fans are used above all-, for large-surface air flow in devices. The air flows through the roller-shaped impellers twice in the radial direction: in the intake area from the outside to the inside and in the outflow area from the inside to the outside. Whirls form in the roller due to the vanes which guarantee a steady flow of air through the impeller. 13 AC axial fans AC centrifugal fans Accessories Representatives Selecting the correct fan 1. Dissipated energy A large amount of the energy consumed by electrical and electronic devices is converted into heat. In selecting the correct fan, therefore, it is important to determine the dissipated energy that must be removed. The electrical power consumption of the unit to be cooled, often represents a suitable value for this purpose. 2. Permissible temperature rise The air flow which the selected fan is required to generate, is determined by the dissipated energy and the permissible rise (ΔT) of the cooling air flow (from entry to exit of the device to be cooled). The max. allowable ΔT depends greatly on the temperature sensitivity of the individual device components. ΔT = 5K means e.g. that the average air flow leaving the device to be cooled may only be 5°C warmer than the ambient temperature (a large volume of air is required for this purpose). A lower air flow rate is sufficient if a higher temperature difference (e.g. ΔT = 20K), can be tolerated. 3. Required cooling air flow • In the below diagram a horizontal line is drawn from the dissipated enery to intersect with the selected ΔT line. • Read down from this point to obtain the required value for the cooling air flow. The diagram is based on the following formula: V· [m3/h] ≈ 3 · Pv [w] ΔT [K] 4. Optimum operating range The required fan, however, must also be able to deliver a suitable static pressure increase Δpf, in order to force the cooling air through the device. A fan must therefore be selected that provides the required air flow performance within its optimum operating range (see also the air performance curves under technical data). 5. Fan selection If the requirements of an application are fulfilled by more than one fan, the noise level, space requirements, economy and ambient conditions will assist in making the final choice. 14 Information DC axial fans DC centrifugal fans DC fans - specials Fan installation Intake or exhaust side installation Under ideal conditions, the operating point is represented as the intersection between the fan and loss curves, regardless of whether the fan is positioned at the air intake or exhaust side of the device. In addition to ensuring the required flow rate, several additional aspects must be considered for determining an appropriate fan concept. The intake air currents of a fan are mainly laminar, comprising nearly the entire suction area. By contrast, the exhaust air of a fan is generally turbulent, while it flows on a preferred direction, e.g. axial for an axial fan. The turbulences of the exhaust intensify the heat transfer from components within the air currents, so that mounting the fan at the air intake side of the device is recommended for cooling and heating. Mounting the fan at the device intake is also advantageous because the fan will not be subjected to the dissipated heat of the device. Therefore, it operates at low ambient temperatures and has a higher life expectancy. Baffle Multidirectional intake, laminar currents Unidirectional exhaust, turbulent Information on installation When a fan is operated for the first time in an application, the user may have noticed that the flow rate in the device was lower than expected. What is the reason for this? • The values stated in this catalogue were determined under optimum, constant and comparable measurement conditions. • Ideal mounting conditions under which free air intake and exhaust are present are seldom feasible in practice. Quite frequently the fans must be mounted in close proximity to other components or cabinet panels. As a consequence, the intake and exhaust currents may be restricted, causing the air flow to diminish and the noise level to increase. Fans are particularly sensitive to obstructions which are positioned directly in front of the output cross section as they often cause an increase in tonal noise. Our advice: The distance between the fan and adjacent components should be at least equal to the installation depth of the fan. Accident prevention The turning rotor and the high speeds that are sometimes involved mean that our fan products carry an inherent risk of injury. They may only be operated after correct installation and with suitable protective facilities (e.g. with a guard grille). More information can be found in the internet at: www.ebmpapst.com/safety ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Representatives 15 Connection instructions for S-Force fans Special features of S-Force fans The S-Force series is the most powerful product series on the market. S-Force stands for the highest innovation in motor technology, fluid mechanics and electronics. The one-of-a-kind power density of the products requires special attention to the application at the customer's facility. Service life Due to the high currents in the fans, the load on the electrolyte capacitors is greater, which reduces the service life of the capacitor. As a larger or additional capacitor cannot be housed in the fan, the capacitor must be housed in the supply line. If the power pack of the application has a corresponding capacitor, in some cases it may be possible to omit the external capacitor. Fan S-Force axial 8200 / 3200 JH3-JH4 4100 NH3 / NH4 / NH5 / NH6 4100 NH7 / NH8 5300 / 5300 TD 6300 / 6300 TD 2200 FTD S-Force centrifugal RET 97 TD RER 120 TD RER 133 TD RER 160 NTDHH / RG 160 NTDHH REF 175 TD RER 175 TD RER 190 TD / RG 190 TD RER 220 TD / RG 220 TD RER 225 TDM / RG 225 TDM RER 225 TD / RG 225 TD Capacitor required no no yes no no no yes yes no yes no no no no no no +Vs Power Supply M Microcontroller GND Recommended measure: Additional external capacitor (thus must be installed as close to the fan as possible < 30 cm). Recommended capacitors We recommend using the following capacitors from Rubycon: 24 VDC: 50 ZL 680 μF; 12,5 mm x 30 mm or 50 ZLH 680 μF 12,5 mm x 30 mm 48 VDC: 100 YXG 470 μF; 16 mm x 35,5 mm or 100 ZLH 470 μF 16 mm x 31,5 mm Other capacitors with equal or greater capacitance and equal or lower serial resistance can also be used. ebm-papst St. Georgen offers the following capacitors ex stock: 24 VDC: 1000 μF / 50 V, 16 mm x 25 mm Art. No.: 992 0345 000 (LZ 354) 48 VDC: 680 μF / 100 V, 18 mm x 40 mm Art. No. : 992 0355 000 (LZ 355) 16 Information Service life DC axial fans Sound power level Sintec sleeve bearings Ball bearings Power consumption Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve DC centrifugal fans DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans Service life data from ebm-papst St. Georgen Our fans catalogue gives three different values for the service life of each product. The first column usually states the service life L10 at 40°C. the second column usually states the service life L10 at Tmax. Exceptions are marked in the column headings. The third column states the new value, life expectancy L10IPC (40 °C). Bel(A) / Watts RPM °C Hours Hours 5,2 1,8 5 900 -20...+70 85 000 / 42 500 142 500 ➀ 5,4 1,5 6 300 -20...+70 85 000 / 42 500 142 500 ➁ Example of the service life figures on the catalogue page. Service life L10 (40 °C) and L10 (Tmax) The values given in the first two columns have been derived from intensive, in-house service life endurance tests, in which our products are operated in various positions at 40°C and 70°C until they fail. A fan is deemed to have failed when it deviates from its defined air flow and speed values, or when the operating noise becomes noticeable. Such tests can take several years before a representative number of failures have been registered, and even today, some fans are still in the process of endurance testing, even though they began tests in the 1980s. These fans are proof of the legendary "made by ebm-papst" reliability. Test results are presented in a diagram and the service life of the product L10 at the temperature tested is determined on the basis of the Weibull distribution. These tests have given us years of experience in the way various design parameters and temperatures can affect the service life of a product. Data for service life at various temperatures for new products can be stated with a very high degree of precision on the basis of tests, product specifications and of commonalities in the design of the product. Summary: The life span calculations have been carried out to the best of our knowledge and are based on experience gained by ebm-papst. The specified L10 (40 °C), L10 (Tmax) and L10IPC (40 °C) values all allow statements to be made about the theoretical calculated service life under certain assumptions. The values determined here are extrapolations from our own service life tests and from statistical variables. In the respective customer applications, different influences may occur which cannot be included in the calculations due to their complexity. The service life information is explicitly not a guarantee of service life, but strictly a theoretical quality figure. Fans in an endurance test cabinet at ebm-papst St. Georgen. 1500 fans are operated in temperature cabinets until they fail. New: Life expectancy L10IPC (40 °C) The new third service life column states the expected service life L10IPC . This information is based on the international norm IPC 9591. Again here, the foundations for the service life values are our service life endurance tests at high ambient temperatures. The service life at temperatures below the test temperatures is calculated using fixed factors. This method produces much higher service life values, especially at room temperature (see diagram on right). Bathtub curve and Weibull distribution. Example of the influence of factors from various manufacturers on the expected service life. 17 AC centrifugal fans Accessories Representatives Definitions Nominal voltage (Volts) The voltage at which the nominal values (the tabular values listed in this catalogue) were determined. The fan operation for DC fans is not limited to the nominal voltage. Fan speed and fan performance can vary according to the permissible voltage range that is specified on the nameplate of each fan. Be aware here that this is not a pulsed or modulated DC voltage. Frequency (Hz) ebm-papst AC fans are made for operating frequencies of 50 Hz or 60 Hz. Their technical data alter accordingly. Air flow [m3/h] The air performance of the fan in free air operation, i.e. the fan blows into the free space without static pressure build-up. Fan curves The fan curves are determined in accordance with DIN ISO 5801 specifications on a dual-chamber test stand with intake-side measurement. This measurement technique closely approximates the operating conditions experienced in typical applications for fans and yields realistic performance curves. The curves apply to an air density of ρ = 1.2 kg/m3, corresponding to an air pressure of 1013 mbar at 20 °C. Variations in air density affect pressure generation but not the flow rate. The pressure generated at other air densities may be estimated with the formula Δρ2 = Δρ1 (ρ2 / ρ1). The nominal speed values, air flow and power input listed in the table were measured in free air operation with horizontal shaft at an ambient temperature of 20 +5 °C, air density ρ = 1.2 kg/m3 after a warm-up period of 5 min. Optimum operating range During operation, fans are required to produce an air flow with a simultaneous increase of pressure. These operating conditions are described in the section “Optimum Operating Range”. The optimum operating range is therefore always indicated in this catalogue in the shaded area. In this range the fans operate best with respect to efficiency and noise level. Within this optimum operating range the noise level only fluctuates insignificantly. Noise [dB(A), Bel(A)] 1. Sound pressure level – dB(A) Noise ratings of the fan in free air operation, i.e. at maximum flow rate. 2. Sound power level – Bel(A) / dB(A) Extent of the overall sound radiation of the fan. The sound power level is determined in the optimum operating range. PAPST Sintec® sleeve bearings A particularly efficient bearing system with excellent qualities: – Very precise, large sintered bearings – Low running noise – High service life expectancy – Insensitive to shock and vibration Ball bearings Precision ball bearings for particularly high ambient temperatures and high service life expectancy. Input power [Watts] Input performance of the fan motor when operating free blowing at nominal voltage. Depending on the operating condition in the application, the power input may be higher. Temperature range [°C] The permissible ambient temperature range within which the fan can be expected to run continuously. Service life [h] Service life L10 at 40 °C and Tmax Standard figures for service life at ebm-papst. These two temperatures are based on intensive, in-house endurance tests and on the experience more than 60 years developing fans. Life expectancy L10IPC (40 °C) Information calculated in line with the norm IPC 9591. Data based on the internal expected service life at 70°C, more optimistically extrapolated to 40°C. We expressly state that none of the information or data in this catalogue is to be construed as a guarantee or warranty of properties. Unit conversion Air flow 1cfm = 1,7 m3/h 1l/s = 3,6 m3/h 1l/min = 0,06 m3/h Pressure 1Pa = 1x10-5 bar 1 inch H2O = 249 Pa 1 mm H2O = 9,81 Pa Subject to technical alterations. Our products are not designed for use in the aerospace industry! German and international patents, registered designs and utility models. ebm-papst is a registered trademark of ebm-papst Mulfingen GmbH & Co. KG. PAPST, SINTEC, VARIOFAN and Vario-Pro are registered trademarks of ebm-papst St. Georgen GmbH & Co. KG. 18 Information Type code DC axial fans DC centrifugal fans DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans 3-digit DC axial fan e.g. 412 FM Housing dimensions (W x H x D) Value Edge dimensions (W x H) Installation depth (D) 2 25 x 25 mm 8 mm 4 40 x 40 mm 10 / 20 / 25 / 28 mm 5 50 x 50 mm 15 mm 6 60 x 60 mm 15 / 25 / 32 mm 7 70 x 70 mm 15 mm Operating voltage Value Nominal voltage 2 12 V 4 24 V 5 5V 8 48 V 412 FM Motor and housing version Value Version 1 4xx fan, 10 / 20 / 25 / 28 mm (D) 1 6xx fan, 15 / 25 / 32 mm (D) 2 25 / 28 mm (D) 3 63x fan, 25 mm (D) 5 2xx fan, 8 mm (D) Options (various versions possible) A Analogue speed control input (input voltage: 0…5 / 0...10 V DC) D Reinforced flange corners with through-holes (Series 44xx F) Constant speed control independent from operating voltage E Economy fan with round flange F Flat construction / frequency-modulated signal G Sleeve bearing H High speed HH Further increased speed H3-H8 Additional further increased speeds (H8 - maximum fan speed) I Integrated temperature sensor (NTC behaviour, i.e. thermistor) J Jet characteristic / rigid curve L Low speed M Medium speed ML Between low and medium speed N Standard or basic speed (only DC fans) O Multi-option speed control input (analogue or PWM signal) P PWM speed control input (pulse-width modulated signal) R Moisture protection coating Circuit board and winding (IP 20), optional stainless steel ball bearing S Speed signal (additional wires for hall signal, obsolete technology) T External temperature sensor (NTC behaviour, i.e. thermistor) TD Turbo drive (extremely powerful 3-phase motor) U Environmentally friendly fan (min. IP 54) V / VP VARIOFAN W Additional wires (standard length 310 mm) X Mounting bore hole 3.7 mm -xxx Variant number 4-digit DC axial fan, e.g. 4312 GM Housing dimensions (W x H x D) Value Edge dimensions (W x H) Installation depth (D) 2 Ø 220 x 200 mm 51 mm 3 92 x 92 mm 25 / 32 / 38 mm 4 119 x 119 mm 25 / 32 / 38 mm 5 127 x 127 mm 38 mm 5 135 x 135 mm 38 mm 5 140 x 140 mm 51 mm 6 Ø 172 mm 51 mm 6 Ø 172 x 150 / 160 mm 51 mm 7 Ø 150 mm 38 / 55 mm 8 80 x 80 mm 25 / 32 / 38 mm Connection type and direction of rotation Value Connection type Direction of rotation 1 Wires, length = 310 mm 5 Wires, length = 310 mm 6 Plug, 2.8 x 0.8 mm Counter-clockwise (CCW) 7 Plug, 2.8 x 0.8 mm Clockwise (CW) 8 Plug, 2.8 x 0.5 mm Counter-clockwise (CCW) 9 Plug, 2.8 x 0.5 mm Clockwise (CW) 4 3 1 2 GM Motor and housing version Value Version 1 38 mm (D) 2 38 mm (D) 3 32 mm (D) 4 25 / 38 / 51 mm (D) Operating voltage Value Nominal voltage 2 12 V 4 24 V 6 36 V 8 48 V All dimensions in millimetres [mm]. Options (various versions possible) A Analogue speed control input (input voltage: 0…5 / 0...10 V DC) D Reinforced flange corners with through-holes (Series 44xx F) Constant speed control independent from operating voltage DV Diagonal Venturi fan E Economy fan with round flange F Flat construction / frequency-modulated signal G Sleeve bearing H High speed HH Further increased speed H3-H8 Additional further increased speeds (H8 - maximum fan speed) I Integrated temperature sensor (NTC behaviour, i.e. thermistor) J Jet characteristic / rigid curve L Low speed M Medium speed ML Between low and medium speed N Standard or basic speed (only DC fans) O Multi-option speed control input (analogue or PWM signal) P PWM speed control input (pulse-width modulated signal) R Moisture protection coating Circuit board and winding (IP 20), optional stainless steel ball bearing S Speed signal (additional wires for hall signal, obsolete technology) T External temperature sensor (NTC behaviour, i.e. thermistor) TD Turbo drive (extremely powerful 3-phase motor) U Environmentally friendly fan (min. IP 54) V / VP VARIOFAN W Additional wires (standard length 310 mm) X Mounting bore hole 3.7 mm -xxx Variant number 19 AC centrifugal fans Accessories Representatives Type code DC centrifugal fan e.g. RER 160-28/12 N Type RE REF RER RET RG RL RLF RV Housing and fan impeller versions Housing Impeller blade design None Non-curved, no direction of rotation set None Forwards/backwards-curved impeller blades, flat None Backwards-curved impeller blades None Forwards-curved impeller blades Square Forwards/backwards-curved impeller blades Round Forwards-curved impeller blades Round Forwards/backwards-curved impeller blades, flat Round Forwards-curved impeller blades Height fan impeller blade Options (various versions possible) A Analogue speed control input (input voltage: 0…5 / 0...10 V DC) D Reinforced flange corners with through-holes (Series 44xx F) Constant speed control independent from operating voltage E Economy fan with round flange F Flat construction / frequency-modulated signal G Sleeve bearing H High speed HH Further increased speed H3-H8 Additional further increased speeds (H8 - maximum fan speed) I Integrated temperature sensor (NTC behaviour, i.e. thermistor) J Jet characteristic / rigid curve L Low speed M Medium speed ML Between low and medium speed N Standard or basic speed (only DC fans) O Multi-option speed control input (analogue or PWM signal) P PWM speed control input (pulse-width modulated signal) R Moisture protection coating Circuit board and winding (IP 20), optional stainless steel ball bearing S Speed signal (additional wires for hall signal, obsolete technology) T External temperature sensor (NTC behaviour, i.e. thermistor) TD Turbo drive (extremely powerful 3-phase motor) U Environmentally friendly fan (min. IP 54) V / VP VARIOFAN W Additional wires (standard length 310 mm) X Mounting bore hole 3.7 mm -xxx Variant number RER 160-28 / 12 N Diameter fan impeller Operating voltage Value Nominal voltage /12 12 V /14 24 V /18 48 V Tangential blower e.g. QG 030-148/12 Type Housing and fan impeller versions Housing Impeller blade design QG Round Compressor drum Housing dimensions (W x H) Value Edge dimensions (W x H) Impeller length Total length 148 48 x 50 mm 148 mm 201 mm 198 48 x 50 mm 198 mm 258 mm 303 48 x 50 mm 303 mm 363 mm 353 48 x 50 mm 353 mm 413 mm QG 030 - 148 / 12 Diameter fan impeller All dimensions in millimetres [mm]. 20 Operating voltage Value Nominal voltage /12 12 V /14 24 V Information Type code DC axial fans DC centrifugal fans DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans 4-digit GreenTech EC compact fans axial e.g. ACi 4420 HH Housing dimensions (W x H x D) Value Edge dimensions (W x H) Installation depth (D) 1 Ø 98,5 mm 130 mm 3 92 x 92 mm 38 mm 4 119 x 119 mm 25 / 32 / 38 mm 6 Ø 172 51 mm 8 80 x 80 mm 32 mm Operating voltage Value Nominal voltage Frequency 0 115 / 230 V 50 / 60 Hz 1 115 V 2 230 V 50 Hz 50 Hz Design Wide voltage range input (85-265 V AC) AC i 4420 HH Basic design Value Design AC DC basic fan with integrated AC/DC power supply unit ACi EC technology (electronics completely integrated) Motor and housing version Value Version 0 130 mm (D) 1 51 mm (D) 2 38 / 51 mm (D) 3 32 mm (D) 4 25 / 38 mm (D) Bearing type and insulation class Value Bearing type Insulation class 0 Ball bearing E Options (various versions possible) A Analogue speed control input (input voltage: 0…5 / 0...10 V DC) D Reinforced flange corners with through-holes (Series 44xx F) Constant speed control independent from operating voltage E Economy fan with round flange F Flat construction / frequency-modulated signal G Sleeve bearing H High speed HH Further increased speed H3-H8 Additional further increased speeds (H8 - maximum fan speed) I Integrated temperature sensor (NTC behaviour, i.e. thermistor) J Jet characteristic / rigid curve L Low speed M Medium speed ML Between low and medium speed N Standard or basic speed (only DC fans) O Multi-option speed control input (analogue or PWM signal) P PWM speed control input (pulse-width modulated signal) R Moisture protection coating Circuit board and winding (IP 20), optional stainless steel ball bearing S Speed signal (additional wires for hall signal, obsolete technology) T External temperature sensor (NTC behaviour, i.e. thermistor) TD Turbo drive (extremely powerful 3-phase motor) U Environmentally friendly fan (min. IP 54) V / VP VARIOFAN W Additional wires (standard length 310 mm) X Mounting bore hole 3.7 mm -xxx Variant number AC axial fan e.g. 3950 L Housing dimensions (W x H x D) Value Edge dimensions (W x H) Installation depth (D) 3 92 x 92 mm 25 / 38 mm 4 119 x 119 mm 25 / 32 / 38 mm 5 127 x 127 mm 38 mm 5 135 x 135 mm 38 mm 5 140 x 140 mm 51 mm 6 Ø 172 mm 51 / 52 mm 7 Ø 150 mm 55 mm 7 Ø 150 x 172 mm 38 mm 8 80 x 80 mm 38 mm 9 119 x 119 mm 25 mm Operating voltage Value Nominal voltage 0 115 V 2 115 V 3 115 V 4 115 V 5 230 V 6 115 V / 230 V 7 230 V 8 230 V 9 230 V Frequency 60 Hz 60 Hz 60 Hz 50 Hz 50 Hz 50 Hz / 60 Hz 50 Hz 60 Hz 60 Hz 3950 L Options (various versions possible) A Air intake via struts (attachment bore ø) E Made by ebm-papst Mulfingen (6xxx, 7xxx range) or round flange H Speed signal 1 Impulses per 360 degrees (additional magnet sensor and hall sensor) L Low speed M Medium speed N Air intake via struts (ø mounting bore hole) R Moisture protection coating Circuit board and winding (IP 20), optional stainless steel ball bearing S Integrated temperature switch T Assembly bracket U Environmentally friendly fan (min. IP 54) V Air exhaust via struts W Additional wires (standard length 310 mm) X Mounting bore hole 3.7 mm -xxx Variant number Z Air exhaust via struts, reinforced flange corners with through-holes Motor and housing version Value Version 4 Shaded-pole motor, 55 mm (D) medium speed 5 Shaded-pole motor, 38 mm (D) medium / high speed 6 Shaded-pole motor, 38 mm (D) high speed 7 Shaded-pole motor, 38 mm (D) with assembly bracket 8 Shaded-pole motor, slow / medium speed 9 Shaded-pole motor, 25 / 38 mm (D) Bearing type and insulation class Value Bearing type Insulation class 0 Sleeve bearing E 5 Ball bearing E 6 Ball bearing F 8 Ball bearing E All dimensions in millimetres [mm]. 21 AC centrifugal fans Accessories Representatives Type code AC centrifugal fan e.g. RER 160-28/56 S Type RE REF RER RET RG RL RLF RV Housing and fan impeller versions Housing Impeller blade design None Non-curved, no direction of rotation set None Forwards/backwards-curved impeller blades, flat None Backwards-curved impeller blades None Forwards-curved impeller blades Square Forwards/backwards-curved impeller blades Round Forwards-curved impeller blades Round Forwards/backwards-curved impeller blades, flat Round Forwards-curved impeller blades Height fan impeller blade Options (various versions possible) A Intake via bars E Made by ebm-papst Mulfingen (6xxx, 7xxx range) or round flange H Speed signal 1 Impulses per 360 degrees (additional magnet sensor and hall sensor) L Low speed M Medium speed N Fan intake via bars (O mounting bore hole) R Moisture protection coating Circuit board and winding (IP 20), optional stainless steel ball bearing S Integrated temperature switch T Assembly bracket U Environmentally friendly fan (min. IP 54) V Air exhaust via bars W Additional wires (standard length 310 mm) X Mounting bore hole 3.7 mm -xxx Variant number Z Air exhaust via bars, reinforced flange joints with through-holes RER 160-28 / 56 S Diameter fan impeller Operating voltage Value Nominal voltage /00 115 V /06 115 V /50 230 V /56 230 V Frequency 60 Hz 60 Hz 50 Hz 50 Hz DC centrifugal fan e.g. R2E 190-AO 26-05 Note: This type code specifies fans from ebm-papst Mulfingen and can be used to clearly identify and order them: Type A S W V R G B G K Housing and fan impeller versions Axial fan Axial fan with safety grille Axial fan with wall ring Axial combination Centrifugal fan, one-sided intake Centrifugal blower, one-sided intake (with scroll housing) Centrifugal fan, double-sided intake Centrifugal blower, double-sided intake (with scroll housing) Centrifugal combination Diameter fan impeller Mechanical design code R2E 190 - AO26 Mechanical variants code -05 Number of poles (AC) 2 2-pole Number of cores (DC/EC) 1 1-phase/core 3 3-phase/core Motor type D Three-phase motor E One-phase motor with operating capacitor G DC/EC motor All dimensions in millimetres [mm]. 22 Electrical design code Information DC axial fans DC centrifugal fans DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans Quiet but powerful. Our new compact fan in the 420J range is a particularly quiet and energy-efficient DC fan. Compared to its predecessors it uses 70 % less power and is up to 5 dB(A) quieter, and it nonetheless achieves an airflow of 38 m³/h and a pressure build-up of up to 175 Pa in the saddle area – all squeezed in to just 40 x 40 x 28 mm. It works efficiently even in harsh environmental conditions. The ideal choice for IT servers, routers or compact frequency converters and welding inverters. For more information, visit: www.ebmpapst.com 23 AC centrifugal fans Accessories Representatives 24 25 Representatives Accessories AC centrifugal fans AC axial fans ACmaxx / GreenTech EC-Compact fans DC fans - specials DC centrifugal fans DC axial fans 31 DC axial fans / DC diagonal fans 27 DC axial fan overview DC axial fans Information DC axial fans Technical information Range of fans ebm-papst offers you the widest full product line of DC axial and diagonal fans: From 25 mm to 280 mm in size. Every single type of fan can be optimally integrated in the respective device concept. The highly economical brushless motor technology of these fans provides a unique variety of intelligent innovations that can be realised today at prices that would have been unthinkable just a few years ago. Electronic protection against reverse polarity ebm-papst DC fans have electronically commutated drives with electronic protection against reverse polarity. The electronics are conveniently located in the fan hub. Product life expectancy A distinctive feature of DC fan technology is the convincingly high product life expectancy. Thanks to the excellent efficiency of the brushless drives, the thermal load of the bearings is reduced, thus considerably increasing the life expectancy of the fans. Type of protection DC fans with sleeve and ball bearings are powered by class E insulated motors. All ebm-papst fans conform to the requirements of type of protection IP 20. Fans conforming to IP 54 / IP 68 and special types of protection are also available. Voltage range Many of our DC fans can be operated on voltages that are up to 50% lower and 25% higher than their nominal voltage (see Voltage range in the technical tables). This enables the air performance to be adapted to the cooling requirements and allows the noise to be reduced, even if the fan does not have a control input. Closed-loop speed control and monitoring Closed-loop speed control and function monitoring are becoming increasingly important in many applications. ebm-papst offers many fans in the standard design with a control input and open collector speed signal. S-Force The new S-Force fans with their extremely high blower capacity of up to 950 m3/h and pressure build-up of up to 1200 pascals are capable of dealing with the extreme heat load. If needed, these fans can produce up to 100% more output under full load and they work with a much broader delivery bandwidth than current models. This makes them ideal for equipment and systems with a high density of components. Thanks to intelligent motor features, they can be individually adapted for any application. S-Force fans are available in 5 standard dimensions. S-Panther S-Panther power delivered quietly. Wherever there is need for power and reduced noise, fans from the S-Panther range are the right solution. A strong pressure saddle curve at optimum air flow provides the power of a real big cat. 26 Information Page DC axial fans DC centrifugal fans Axial fans for DC operation Overview of air performance Dimensions Series Air flow mm m3/h 10 c 25 x 8 250 2,3...4,6 c 40 x 10 400 F 6...9 c 40 x 20 400 10...13,5 c 40 x 28 420 J 24...38 NEW c 50 x 15 500 F 11...20 c 60 x 15 600 F 19...33 c 60 x 25 620 21...67 c 60 x 25 630 40...44 c 60 x 25 600 N 21...56 c 60 x 25 600 N VARIOFAN 16...41 c 60 x 32 600 J 70...82 c 70 x 15 700 F 28...44 c 80 x 25 8450 32...117 c 80 x 25 8400 N 33...79 c 80 x 25 8400 N VARIOFAN 20...58 c 80 x 32 8300 32...80 c 80 x 38 8200 J 132...222 c 92 x 25 3400 N 61...102 c 92 x 25 3400 N VARIOFAN 44...84 c 92 x 32 3300 56...107 c 92 x 32 3300 N 56...133 NEW c 92 x 38 3200 J 130...280 c 92 x 38 3250 J 145...270 NEW c 119 x 25 4400 F 94...170 c 119 x 25 4400 FN 200...225 c 119 x 32 4300 95...204 c 119 x 32 4300 VARIOFAN 65...170 Subject to alternations 10 m3/h 20 30 40 50 60 70 80 90 100 20 30 40 50 60 70 80 90 100 200 300 400 500 600 700 800 900 1000 200 300 400 500 600 700 800 900 1000 2000 3000 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 2000 3000 DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Representatives 27 Dimensions Series Air flow Page Axial fans for DC operation Overview of air performance mm m3/h 10 c 119 x 38 4400 100...285 c 119 x 38 4100 N 160...237 c 119 x 38 4100 NHH..NH6 260...440 c 119 x 38 4100 NH7..NH8 500...570 c 119 x 38 DV 4100 c 127 x 38 5200 N 280 187...340 c 127 x 38 DV 5200 270...320 c 135 x 38 5100 N 260 c 140 x 51 5300 340 c 140 x 51 5300 TD 410...670 Ø 150 x 38 7100 N 308...360 Ø 150 x 55 7200 N 360 172x160x52 6100 N 350 Ø 172 x 51 6300 395...545 Ø 172 x 51 6300 TD 600...930 172x160x51 6300 TD 710...930 Ø 172 x 51 DV 6300 630...1100 NEW 172x150x51 6400 350...480 172x150x51 6400 TD Turbofan 90...900 172x160x51 DV 6400 530 172x160x51 DV 6400 TD Turbofan100...680 220x200x51 2200 FTD 790...1220 c 225 x 80 2200 TD c 225 x 80 K1G 200 1000 1020...1245 c 225 x 89 K3G 200 725...905 Ø 250 W1G 250 2070 Ø 300 *1G 300 2320...2345 Subject to alternations 10 m3/h 20 30 40 50 60 70 80 90 100 20 30 40 50 60 70 80 90 100 200 300 400 500 600 700 800 900 1000 200 300 400 500 600 700 800 900 1000 2000 3000 58/59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 86 2000 3000 28 Information DC axial fans DC centrifugal fans Axial fans for DC operation Overview of technically feasible designs Dimensions VDE, UL, CSA IIISSAPEPASHGRinlPPMpxatanoeunatluWteeglrvat/>>elretemeeirMifconm=r=d-NnodgasIsciIoolilasgtluwioPP-peibtytletgtnepgiet65revhenpoorc8r4oelamnotodilmaloiplbtenrpictmeeaeciereonrrtatcricronaptitlitaotmisuntriontuopguornnlnsere/pieebounsdftaslpelreunobnttsesaoaotrririonngs Axial fans Series mm OPTIONAL p. 250 25 x 25 x 8 ja • – – – – – – – • – – – – 31 400 F 40 x 40 x 10 ja • • – – – – – – • – – – – 32 400 40 x 40 x 20 ja • • – – – • – – • – – – – 33 NEW 420 J 40 x 40 x 28 ja • • – • – • – – • – – • – 34 500 F 50 x 50 x 15 ja • • – – – • – – • – – – – 35 600 F 60 x 60 x 15 ja • • – – – • – – • – – – – 36 620 60 x 60 x 25 ja • • • • • • • – • – – – – 37 630 60 x 60 x 25 ja • • • • – • • – • • • • – 38 600 N 60 x 60 x 25 ja / • • – – – – – – • • • – – 39 600 N VARIOFAN 60 x 60 x 25 ja / • • – • • – – – • – – – – 40 600 J 60 x 60 x 32 ja • • – • – • • – • – – – – 41 700 F 70 x 70 x 15 ja • • – – – – – – • – – – – 42 8450 80 x 80 x 25 ja / • • • • • • • – • – – – – 43 8400 N 80 x 80 x 25 ja / • • • • • • • – • • • – – 44 8400 N VARIOFAN 80 x 80 x 25 ja • • – • • – – – • – – – – 45 8300 80 x 80 x 32 ja • • • • • • • – • • • • – 46 8200 J 80 x 80 x 38 ja • • • • • • • – • • – – – 47 3400 N 92 x 92 x 25 ja / • • • • • • • – • • • – – 48 3400 N VARIOFAN 92 x 92 x 25 ja • • – • • – – – • – – – – 49 3300 92 x 92 x 32 ja / • • • • • • • – • • • • – 50 NEW 3300 N 92 x 92 x 38 ja • • – • • • • – • • – • – 51 3200 J 92 x 92 x 38 ja • • • • • • • – • • • – – 52 NEW 3250 J 92 x 92 x 38 ja • • – • • • • – • • – • – 53 4400 F 119 x 119 x 25 ja / • • • • • • • – • – – – – 54 4400 FN 119 x 119 x 25 ja • • • • • • • – • – – – – 55 4300 119 x 119 x 32 ja / • • • • • • • – • • • • – 56 4300 VARIOFAN 119 x 119 x 32 ja Subject to alternations • • • • • • • – • – – – – 57 * approvalsapplied for – not yet available • available Sleeve bearings Ball bearings Please note that these special versions are not possible for all voltages and speeds, and not in all combinations. The special versions are designed for specific customers and projects. As a rule they are not available off the shelf and are tied to minimum volumes. Please consult your customer support representative about the feasibility of your special variant. DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Representatives 29 Axial fans for DC operation Overview of technically feasible designs Dimensions VDE, UL, CSA IIISSAPEPASHGRinlPPMpxatanoeunatluWteeglrvat/>>elretemeeirMifconm=r=d-NnodgasIsciIoolilasgtluwioPP-peibtytletgtnepgiet65revhenpoorc8r4oelamnotodilmaloiplbtenrpictmeeaeciereonrrtatcricronaptitlitaotmisuntriontuopguornnlnsere/pieebounsdftaslpelreunobnttsesaoaotrririonngs Axial fans Series mm 4400 119 x 119 x 38 4100 N 119 x 119 x 38 4100 NH..NH6 119 x 119 x 38 4100 NH7..NH8 119 x 119 x 38 DV 4100 119 x 119 x 38 5200 N 127 x 127 x 38 DV 5200 127 x 127 x 38 5100 N 135 x 135 x 38 5300 140 x 140 x 51 5300 TD 140 x 140 x 51 7100 N Ø 150 x 38 7200 N Ø 150 x 55 6100 N 172 x 160 x 51 6300 Ø 172 x 51 6300 TD Ø 172 x 51 6300 TD 172 x 160 x 51 NEW DV 6300 172 x 160 x 51 6400 172 x 150 x 51 6400 TD Turbofan 172 x 150 x 51 DV 6400 172 x 160 x 51 DV 6400 TD 172 x 160 x 51 2200 FTD Ø 200 x 51 NEW 2200 TD 225 x 225 x 80 K1G 200 225 x 225 x 80 K3G 200 225 x 225 x 89 Subject to alternations ja ja / ja ja ja ja ja ja ja ja ja ja ja ja ja ja ja ja ja ja ja ja ja ja ja • •• • •• • •• • •• • •• • •• • •• • •• • •• • •• • •• • •• • •• • •• • •• • •• • •• • •• • •• • •• • •• • •• • •• • •• • •• OPTIONAL •• ••– •• ••– •• ••– •• ••– •• ••– •• ••– •• ••– •• ••– •• ••– •• ••• •• ••– •• ••– •• ••– •• ••– •• ••• •• ••• •• ••• •• ••– •• ••– •• ••– •• ••– •• ••• •• ••• •– ••• •– ••• ••––– ••••– ••••– •––•– ••••– ••••– ••–•– ••–•– ••–•– ••–•– ••••– ••••– ••––– ••–•– ••–•– ••–•– ••–•– ••–•– ••–•• ••–•– ••–•• ••–•– ••––– •––•– •––•– p. 58/59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 Please note that these special versions are not possible for all voltages and speeds, and not in all combinations. The special versions are designed for specific customers and projects. As a rule they are not available off the shelf and are tied to minimum volumes. Please consult your customer support representative about the feasibility of your special variant. * approvalsapplied for – not yet available • available Sleeve bearings Ball bearings 30 Information DC axial fans DC centrifugal fans max. 4,6 m3/h DC axial fans Series 250 25 x 25 x 8 mm – Material: Housing: GRP1) (PBT) Impeller: GRP1) (PA) – Direction of air flow: Exhaust over struts – Direction of rotation: Counter-clockwise, seen on rotor – Connection: Via single wires AWG 28, TR 64 – Mass: 5g – Possible special versions: (See chapter DC fans - specials) - Speed signal - Protection against moisture 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (20 °C) ebm-papst Standard Service life L10 (60 °C) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type 255 M 255 N 255 H 252 N 252 H Subject to alternations m3/h CFM VDC VDC dB(A) Bel(A) / 2,3 1,2 3,5 1,9 4,6 2,6 5 4,5...5,5 5 < 3 5 4,5...5,5 16 < 3 5 4,5...5,5 23 4,4 3,4 1,9 12 10...14 15 < 3 4,6 2,6 12 10...14 23 4,4 Watts rpm 0,2 6 500 0,4 9 600 0,6 12 000 0,5 9 000 0,7 12 000 °C -10...+70 -10...+70 -10...+55 -10...+70 -10...+55 Hours Hours 45 000 / 17 500 47 500 ➀ 40 000 / 15 000 42 500 ➁ 35 000 / 15 000* 37 500 ➂ 40 000 / 15 000 42 500 ➁ 35 000 / 15 000* 37 500 ➂ * at 55 °C DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Pa [in H O] 2 Accessories 50 40 3 0,15 30 2 0,10 20 1 0,05 10 0 0,4 0,8 1,2 1,6 2,0 2,4 CFM 1 2 3 4 m³/h Guard grilles from p. 238 tin-plated 31 Representatives 9 max. m3/h DC axial fans Series 400 F 40 x 40 x 10 mm – Material: Housing: GRP1) (PBT) Impeller: GRP1) (PA) – Direction of air flow: Exhaust over struts – Direction of rotation: Counter-clockwise, seen on rotor – Connection: Via single wires AWG 28, TR 64 – Highlights: Some models are suitable for use at high ambient temperatures – Mass: 17 g – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - Protection against moisture 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (20 °C) ebm-papst Standard Service life L10 (60 °C) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type 405 F 405 FH 412 FM 412 F 412 FH 414 F 414 FH m3/h CFM VDC VDC dB(A) Bel(A) / 8 4,7 9 5,3 5 4,5...5,5 5 4,5...5,5 22,1 4,4 26,0 4,6 6 3,5 12 10...14 17,0 3,8 8 4,7 12 10...14 22,1 4,4 9 5,3 12 10...14 26,0 4,6 8 4,7 24 20...28 22,1 4,4 9 5,3 24 21,6...26,4 26,0 4,4 Watts 0,7 0,9 0,5 0,7 0,8 0,8 0,9 rpm 5 400 6 000 4 300 5 400 6 000 5 400 6 000 °C -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 Hours Hours 45 000 / 17 500 45 000 / 17 500 47 500 ➁ 47 500 ➂ 45 000 / 17 500 45 000 / 17 500 45 000 / 17 500 47 500 ➀ 47 500 ➁ 47 500 ➂ 45 000 / 17 500 45 000 / 17 500 47 500 ➁ 47 500 ➂ Model with temperature range up to +85 °C. 412 FM-074 6 3,5 12 412 F-130 8 4,7 12 412 FH-132 9 5,3 12 Subject to alternations 10...14 10...14 10...14 17,0 3,8 22,1 4,4 26,0 4,6 0,4 4 300 -20...+85 45 000 / 17 500 47 500 ➀ 0,6 5 400 -20...+85 45 000 / 17 500 47 500 ➁ 0,8 6 000 -20...+85 45 000 / 17 500 47 500 ➂ Pa [in H2O] 0,02 0,04 0,06 0,08 0,10 3 30 25 2 20 1 15 10 5 0 1 2 3 4 5 CFM 2 4 6 8 m³/h 32 Guard grilles from p. 238 tin-plated Information DC axial fans DC centrifugal fans max. 13,5 m3/h DC axial fans Series 400 40 x 40 x 20 mm – Material: Housing: GRP1) (PBT) Impeller: GRP1) (PA) – Direction of air flow: Exhaust over struts – Direction of rotation: Counter-clockwise, seen on rotor – Connection: Via single wires AWG 28, TR 64 – Highlights: Some models are suitable for use at high ambient temperatures – Mass: 27 g – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - PWM control input - Protection against moisture 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (20 °C) ebm-papst Standard Service life L10 (60 °C) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type 405 412 412 H 414 414 H m3/h CFM VDC VDC dB(A) Bel(A) / 10,0 5,9 5 4,5...5,5 18 3,8 10,0 5,9 12 10...14 18 3,8 13,5 7,9 12 10...14 29 4,7 10,0 5,9 24 20...28 18 3,8 13,5 7,9 24 20...26,5 29 4,7 Model with temperature range up to +85 °C. 412-099 Subject to alternations 10,0 5,9 12 10...14 18 3,8 Watts 0,9 0,8 1,6 1,0 1,7 rpm 6 000 6 000 8 100 6 000 8 100 °C -20...+70 -20...+70 -20...+60 -20...+70 -20...+60 Hours Hours 50 000 / 20 000 52 500 ➀ 50 000 / 20 000 45 000 / 17 500 52 500 ➀ 47 500 ➁ 50 000 / 20 000 45 000 / 17 500 52 500 ➀ 47 500 ➁ 0,8 6 000 -20...+85 50 000 / 20 000 52 500 ➀ DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Pa [in H O] 2 Accessories 0,15 2 50 40 1 30 20 10 0,10 0,05 0 1 2 3 4 5 6 7 CFM 2 4 6 8 10 m³/h Guard grilles from p. 238 tin-plated 33 Representatives 38 max. m3/h DC axial fans Series 420 J 40 x 40 x 28 mm – Material: Housing: GRP1) (PBT) Impeller: GRP1) (PA) – Direction of air flow: Exhaust over struts – Direction of rotation: Counter-clockwise, seen on rotor – Connection: Via single wires AWG 28, UL 1061 – Mass: 45 g – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - External temperature sensor - PWM control input - Protection against moisture - Protection against salt fog 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (20 °C) ebm-papst Standard Service life L10 (60 °C) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type 422 JM 422 JN 422 JH 424 JM 424 JN 424 JH Subject to alternations m3/h CFM VDC VDC dB(A) Bel(A) / 24 14,2 12 8...13,8 42 5,5 31 18,3 12 8...13,8 48 6,0 38 22,4 12 8...13,8 54 6,6 24 14,2 24 16...28 42 5,5 31 18,3 24 16...28 48 6,0 38 22,4 24 16...26,4 54 6,6 Watts rpm 2,5 11 100 4,0 14 000 6,8 17 200 2,7 11 100 4,2 14 000 7,1 17 200 °C -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 -20...+65 Hours Hours 75 000 / 37 500 127 500 ➀ 67 500 / 35 000 115 000 ➁ 60 000 / 30 000 102 500 ➂ 75 000 / 37 500 127 500 ➀ 67 500 / 35 000 115 000 ➁ 60 000 / 32 500 102 500 ➂ Pa [in H2O] 3 400 0,2 0,5 0,75 1,0 1,25 1,5 350 300 2 250 200 1 150 100 50 0 5 10 15 20 CFM 5 10 15 20 25 30 35 40 m³/h 34 Guard grilles from p. 238 tin-plated Ø 42,5 ± 0,3 Information DC axial fans DC centrifugal fans 20 max. m3/h DC axial fans Series 500 F 50 x 50 x 15 mm – Material: Housing: GRP1) (PBT) Impeller: GRP1) (PA) – Direction of air flow: Exhaust over struts – Direction of rotation: Counter-clockwise, seen on rotor – Connection: Via single wires AWG 28, TR 64 – Highlights: Some models are suitable for use at high ambient temperatures – Mass: 27 g – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - PWM control input - Protection against moisture 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (20 °C) ebm-papst Standard Service life L10 (60 °C) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type 512 F 514 F m3/h CFM VDC VDC dB(A) Bel(A) / 20 11,8 12 10,8...13,2 30 4,5 20 11,8 24 21,6...26,4 30 4,5 Model with temperature range up to +85 °C. 512 FL-547 512 F-532 Subject to alternations 11 6,5 12 10,2...13,8 18 3,7 20 11,8 12 10,8...13,2 30 4,5 Watts 0,8 0,9 rpm 5 000 5 000 °C -20...+70 -20...+70 Hours Hours 50 000 / 20 000 52 500 ➁ 50 000 / 20 000 52 500 ➁ 0,4 3 000 -20...+85 50 000 / 20 000 52 500 ➀ 0,9 5 000 -20...+85 50 000 / 20 000 52 500 ➁ DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Pa [in H O] 2 Accessories 0,02 0,04 0,06 0,08 0,10 30 2 25 20 15 10 1 5 0 2 4 6 5 10 8 15 10 CFM m³/h Guard grilles from p. 238 tin-plated 35 Representatives 33 max. m3/h DC axial fans Series 600 F 60 x 60 x 15 mm – Material: Housing: GRP1) (PBT) Impeller: GRP1) (PA) – Direction of air flow: Exhaust over struts – Direction of rotation: Counter-clockwise, seen on rotor – Connection: Via single wires AWG 28, TR 64 – Highlights: Some models are suitable for use at high ambient temperatures – Mass: 30 g – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - PWM control input - Protection against moisture 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (20 °C) ebm-papst Standard Service life L10 (60 °C) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type 605 F 612 FL 612 F 612 FH 614 F 614 F/39 H-691 m3/h CFM VDC VDC dB(A) Bel(A) / 29 17,1 5 4,5...5,2 27 4,4 19 11,2 12 11,5...13,2 16 3,6 29 17,1 12 10,8...13,2 27 4,4 33 19,4 12 10,0...13,2 31 4,8 29 17,1 24 21,6...26,4 27 4,4 33 19,4 24 16...28 31 4,8 Model with temperature range up to +80 / 85 °C. 612 FL-680 612 F-637 Subject to alternations 19 11,2 12 11,5...14 16 3,6 29 17,1 12 10,8...12,6 27 4,4 Watts 1,1 0,4 1,0 1,5 1,1 1,4 rpm 4 000 2 650 3 900 4 500 3 900 4 500 °C -20...+50 -20...+70 -20...+70 -20...+60 -20...+70 -20...+60 Hours Hours 50 000 / 20 000 52 500 ➁ 50 000 / 20 000 50 000 / 20 000 45 000 / 17 500 52 500 ➀ 52 500 ➁ 47 500 ➂ 50 000 / 20 000 52 500 ➁ 45 000 / 17 500 47 500 ➂ 0,5 2 650 -20...+85 50 000 / 20 000 52 500 ➀ 1,0 3 900 -20...+80 50 000 / 20 000 52 500 ➁ Pa [in H2O] 0,02 0,04 0,06 0,08 3 25 2 20 15 10 1 5 0 3 6 9 12 15 18 CFM 5 10 15 20 25 m³/h 36 Guard grilles from p. 238 tin-plated Information DC axial fans DC centrifugal fans 67 max. m3/h DC axial fans Series 620 60 x 60 x 25 mm – Material: Housing: GRP1) (PBT) Impeller: GRP1) (PA) – Direction of air flow: Exhaust over struts – Direction of rotation: Clockwise, seen on rotor – Connection: Via single wires AWG 22, TR 64 – Highlights: Very low-noise motor – Mass: 85 g – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Protection against moisture 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type 622 L 622 M 622 N 622 H 622 HH 622/2 H3P 624 L 624 M 624 N 624 H 624 HH 624/2 H3P 628 HH Subject to alternations m3/h CFM VDC VDC dB(A) Bel(A) / 21 12,4 12 8...15 20 3,7 30 17,7 12 8...15 29 4,3 40 23,5 12 8...15 35 4,7 46 27,1 12 8...15 39 5,1 56 33,0 12 8...15 43 5,6 67 39,4 12 8...13,2 48 5,9 21 12,4 24 18...28 20 3,7 30 17,7 24 12...28 29 4,3 40 23,5 24 12...28 35 4,7 46 27,1 24 18...28 39 5,1 56 33,0 24 18...28 43 5,6 67 39,4 24 18...28 48 5,9 56 33,0 48 36...60 43 5,6 Watts 0,5 1,0 1,9 2,3 3,5 8,0 1,0 1,5 2,2 2,4 3,6 7,0 4,2 rpm 3 200 4 550 6 100 6 850 8 200 9 700 3 200 4 550 6 100 6 850 8 200 9 700 8 200 °C -20...+85 -20...+75 -20...+70 -20...+70 -20...+70 -20...+60 -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 -20...+60 -20...+70 Hours Hours 80 000 / 20 000 135 000 ➀ 77 500 / 30 000 127 500 ➁ 72 500 / 35 000 117 500 ➂ 70 000 / 35 000 117 500 ➃ 65 000 / 32 500 110 000 ➄ 52 500 / 32 500 87 500 ➅ 80 000 / 40 000 135 000 ➀ 77 500 / 37 500 130 000 ➁ 72 500 / 35 000 117 500 ➂ 70 000 / 35 000 117 500 ➃ 65 000 / 32 500 110 000 ➄ 52 500 / 32 500 87 500 ➅ 65 000 / 32 500 110 000 ➄ DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans [in H2O] Pa Accessories 6 175 0, 6 140 5 0,4 105 4 3 70 2 0, 2 35 1 0 10 20 30 CFM 10 20 30 40 50 60 m³/h Guard grilles from p. 238 tin-plated 37 Representatives 44 max. m3/h DC axial fans Series 630 60 x 60 x 25 mm – Material: Housing: GRP1) (PBT) – Possible special versions: Impeller: GRP1) (PA) (See chapter DC fans - specials) – Direction of air flow: Exhaust over struts - Speed signal – Direction of rotation: Clockwise, seen on rotor - Go / No-go alarm – Connection: Via single wires AWG 22, - Alarm with limit speed TR 64 - External temperature sensor – Highlights: Developed for applications with - PWM control input demanding environmental - Analogue control input requirements - Protection against moisture – Mass: 70 g - Protection against salt fog - Type of protection: IP 54 / IP 68 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type 632 NU 632/2 HPU 634 NU 638/2 HPU Subject to alternations m3/h CFM VDC VDC dB(A) Bel(A) / 40 23,5 12 6...15 33 5,2 44 25,9 12 10,8...13,2 35 5,4 40 23,5 24 12...30 34 5,1 44 25,9 48 40...60 35 5,4 Watts 1,8 1,5 1,6 1,8 rpm 5 900 6 300 5 900 6 300 °C -20...+70 -20...+70 -20...+70 -20...+70 Hours Hours 85 000 / 42 500 142 500 ➀ 85 000 / 42 500 142 500 ➁ 85 000 / 42 500 142 500 ➀ 85 000 / 42 500 142 500 ➁ 38 Guard grilles from p. 238 tin-plated Information DC axial fans 56 max. m3/h DC axial fans Series 600 N 60 x 60 x 25 mm – Material: Housing: GRP1) (PBT) Impeller: GRP1) (PA) – Direction of air flow: Exhaust over struts – Direction of rotation: Clockwise, seen on rotor – Connection: Via single wires AWG 22, TR 64 – Highlights: Some models are suitable for use at high ambient temperatures until 85 °C – Mass: 66 g – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - Protection against moisture - Type of protection: IP 54 / IP 68 1) Fibreglass-reinforced plastic DC centrifugal fans Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans Nominal data Type 612 NGLE 612 NLE 612 NGMLE 612 NMLE 612 NGME 612 NME 612 NN 612 NH 612 NHH-118 614 NGL 614 NL 614 NGML 614 NML 614 NGM 614 NM 614 NN 614 NH 614 NHH 614 NHH-119 618 NM 618 NN m3/h CFM VDC VDC dB(A) Bel(A) / 21 12,4 12 8...15 21 12,4 12 8...15 25 14,7 12 8...15 25 14,7 12 8...15 35 20,6 12 8...15 35 20,6 12 8...15 42 24,7 12 8...15 43 25,3 12 8...15 56 33,0 12 8...15 21 12,4 24 18...28 21 12,4 24 18...28 25 14,7 24 18...28 25 14,7 24 18...28 35 20,6 24 18...28 35 20,6 24 18...28 42 24,7 24 18...28 43 25,3 24 18...26 56 33,0 24 18...26 56 33,0 24 18...28 35 20,6 48 36...56 42 24,7 48 36...56 16 3,6 16 3,6 19 3,9 19 3,9 28 4,6 28 4,6 35 5,0 37 5,3 41 5,7 16 3,6 16 3,6 19 3,9 19 3,9 28 4,6 28 4,6 35 5,0 37 5,3 41 5,7 41 5,7 28 4,6 35 5,0 Watts 0,6 0,4 0,7 0,4 1,2 0,8 1,5 1,8 2,9 1,0 0,8 1,2 1,0 1,7 1,3 1,8 2,1 2,9 2,9 1,9 2,1 rpm 2 500 2 500 3 000 3 000 4 100 4 100 5 100 5 600 6 800 2 500 2 500 3 000 3 000 4 100 4 100 5 100 5 600 6 850 6 850 4 100 5 100 °C -20...+85 -20...+85 -20...+80 -20...+85 -20...+75 -20...+75 -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 -20...+65 Hours Hours 80 000 / 27 500 135 000 ➀ 80 000 / 27 500 135 000 ➀ 80 000 / 32 500 135 000 ➁ 80 000 / 27 500 135 000 ➁ 80 000 / 35 000 135 000 ➂ 80 000 / 35 000 135 000 ➂ 70 000 / 35 000 117 500 ➃ 70 000 / 35 000 117 500 ➄ 60 000 / 30 000 102 500 ➅ 80 000 / 40 000 135 000 ➀ 80 000 / 40 000 135 000 ➀ 80 000 / 40 000 135 000 ➁ 80 000 / 40 000 135 000 ➁ 80 000 / 40 000 135 000 ➂ 80 000 / 40 000 135 000 ➂ 70 000 / 35 000 117 500 ➃ 70 000 / 35 000 117 500 ➄ 60 000 / 30 000 102 500 ➅ 60 000 / 30 000 102 500 ➅ 80 000 / 40 000 135 000 ➂ 70 000 / 40 000 117 500 ➃ Pa [in H2O] 100 6 80 5 0, 3 60 4 0, 2 0, 1 3 40 2 20 1 0 5 10 15 20 25 30 CFM 10 20 30 40 50 m³/h tin-plated Guard grilles from p. 238 39 AC centrifugal fans Accessories Representatives 41 max. m3/h DC axial fans Series 600 N VARIOFAN 60 x 60 x 25 mm – Material: Housing: GRP1) (PBT) Impeller: GRP1) (PA) – Direction of air flow: Exhaust over struts – Direction of rotation: Clockwise, seen on rotor – Connection: Via single wires AWG 22, TR 64 – Highlights: Automatic speed adjustment with temperature sensor – Mass: 66 g – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - External temperature sensor - Internal temperature sensor - Protection against moisture 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type 30°C 612 NGMI 55°C 30°C 612 NMI 55°C 30°C 612 NGNI 55°C 30°C 612 NNI 55°C 30°C 55°C 612 NGNV Subject to alternations m3/h CFM VDC VDC dB(A) Bel(A) / 18 10,6 35 20,6 16 9,4 35 20,6 23 13,5 41 24,1 23 13,5 41 24,1 23 13,5 41 24,1 12 8...12,6 12 8...12,6 12 8...12,6 12 8...12,6 12 8...12,6 14 3,5 28 4,6 16 3,6 28 4,6 18 3,8 35 5,0 18 3,8 35 5,0 18 3,8 35 5,0 Watts 1,3 1,7 1,0 1,4 1,7 2,4 1,2 1,5 1,7 2,4 rpm 2 150 4 100 2 400 4 100 2 900 5 100 2 900 5 100 2 900 5 100 °C -20...+65 -20...+65 -20...+65 -20...+65 -20...+65 Hours Hours ➀ 80 000 / 45 000 135 000 ➁ ➂ 80 000 / 45 000 135 000 ➃ ➄ 70 000 / 40 000 117 500 ➅ ➄ 70 000 / 40 000 117 500 ➅ ➄ 70 000 / 40 000 117 500 ➅ [in H O] 2 [in H2O] [in H O] 2 Pa 2 40 612 NGMI 0,15 30 0,10 20 1 10 0,05 30°C 55°C 0 3 6 9 12 15 18 CFM 5 10 15 20 25 30 m³/h Pa 4 40 612 NMI 0,15 30 0,10 20 3 10 0,05 30°C 55°C 0 3 6 9 12 15 18 CFM 5 10 15 20 25 30 m³/h Pa 0,25 6 60 612 NGNI 612 NNI 612 NGNV 0,20 0,15 40 5 20 0,10 0,05 30°C 55°C 0 4 8 12 16 20 CFM 10 20 30 m³/h V-Types I-Types tin-plated The temperature sensor for controlling the motor speed is not included in delivery. Temperature sensor LZ 370 see accessories. 40 Guard grilles from p. 238 Temperature sensor (NTC-resistor) for controlling the motor speed is positioned directly in the air flow. Information DC axial fans DC centrifugal fans 82 max. m3/h DC axial fans Series 600 J 60 x 60 x 32 mm – Material: Housing: GRP1) (PBT) Impeller: GRP1) (PA) – Direction of air flow: Exhaust over struts – Direction of rotation: Clockwise, seen on rotor – Connection: Via single wires AWG 24, TR 64 – Mass: 100 g – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - PWM control input - Analogue control input - Protection against moisture 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type m3/h CFM VDC VDC dB(A) Bel(A) / 612 JH 70 41,1 12 7...13,6 53 6,4 614 JH 70 41,1 24 14...26,4 53 6,4 618 JH 70 41,1 48 36...56 53 6,4 Fan types with streamer and integrated guard grille. 614 J/2 HHP 82 48,3 24 18...30 62 7,6 618 J/2 HHP Subject to alternations 82 48,3 48 38...58 62 7,6 Watts rpm 7,7 11 700 7,7 11 700 7,7 11 700 °C -20...+70 -20...+70 -20...+70 Hours 57 500 / 27 500 57 500 / 27 500 57 500 / 27 500 Hours 97 500 ➀ 97 500 ➀ 97 500 ➀ 14,6 15 000 14,6 15 000 -20...+75 -20...+75 65 000 / 25 000 110 000 ➁ 65 000 / 25 000 110 000 ➁ DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Rear view of types 614 J/2HHP and 618 J/2HHP tin-plated Guard grilles from p. 238 41 Representatives 44 max. m3/h DC axial fans Series 700 F 70 x 70 x 15 mm – Material: Housing: GRP1) (PBT) Impeller: GRP1) (PA) – Direction of air flow: Exhaust over struts – Direction of rotation: Counter-clockwise, seen on rotor – Connection: Via single wires AWG 24 to AWG 28, TR 64 – Mass: 53 g – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - Protection against moisture 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type 712 F/2L-005* 712 F/2M-006* 712 F 714 F Subject to alternations m3/h CFM VDC VDC dB(A) Bel(A) / 28 16,5 12 8...13,8 25 4,7 36 21,2 12 8...13,8 32 5,0 44 25,9 12 8...13,8 38 5,3 44 25,9 24 18...28 38 5,3 *Version with 3-pin Molex plug housing Molex Contacts 22-01-2035 08-50-0113 Watts 0,6 1,1 1,7 1,5 rpm 3 300 4 300 5 300 5 300 °C -20...+70 -20...+70 -20...+70 -20...+70 Hours Hours 60 000 / 30 000 102 500 ➀ 60 000 / 30 000 102 500 ➁ 60 000 / 30 000 102 500 ➂ 60 000 / 30 000 102 500 ➂ Pa [in H2O] 0,20 0,15 60 3 50 40 2 30 20 1 10 0,10 0,05 0 4 8 12 16 20 24 CFM 10 20 30 40 m³/h 42 Guard grilles from p. 238 tin-plated Information DC axial fans DC centrifugal fans max. 117 m3/h DC axial fans Series 8450 80 x 80 x 25 mm – Material: Housing: GRP1) (PBT) Impeller: GRP1) (PA) – Direction of air flow: Exhaust over struts – Direction of rotation: Counter-clockwise, seen on rotor – Connection: Via single wires AWG 24, TR 64 – Highlights: Very low-noise motor – Mass: 105 g – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Protection against moisture 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type 8452 GL 8452 GM 8452 GN m3/h CFM VDC VDC 32 18,8 58 34,1 68 40,0 12 8...15 12 8...15 12 8...15 dB(A) Bel(A) / 14 3,3 32 4,7 36 5,0 Watts 0,4 1,3 1,8 rpm 1 700 3 100 3 600 °C -20...75 -20...75 -20...70 Hours Hours 80 000 / 35 000 135 000 ➀ 80 000 / 35 000 135 000 ➁ 70 000 / 35 000 117 500 ➂ Models with 25 kHz PWM control and speed signal to 4-wire specification (see page 175). 8452/2 GHP 75 44,1 12 10,8...13,2 38 5,3 8452/2 GHHP 83 48,8 12 10,8...13,2 42 5,5 2,5 4 000 -20...70 3,5 4 400 -20...60 70 000 / 35 000 117 500 ➃ 65 000 / 40 000 110 000 ➄ Models with 1-30 kHz PWM control and speed signal. 8452/2 H4P 117 68,8 12 8...15 50 6,4 8454/2 H4P Subject to alternations 117 68,8 24 20,0...26,4 50 6,4 6,8 6 200 -20...70 6,8 6 200 -20...70 60 000 / 30 000 102 500 ➅ 60 000 / 30 000 102 500 ➅ DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Guard grilles from p. 238 tin-plated 43 Representatives 79 max. m3/h DC axial fans Series 8400 N 80 x 80 x 25 mm – Material: Housing: GRP1) (PBT) Impeller: GRP1) (PA) – Direction of air flow: Exhaust over struts – Direction of rotation: Counter-clockwise, seen on rotor – Connection: Via single wires AWG 24, TR 64 – Highlights: Some models are suitable for use at high ambient temperatures until 85 °C – Mass: 95 g – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Protection against moisture - Type of protection: IP 54 / IP 68 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Pa 0,05 0,10 0,15 [in H2O] Type 8412 NGLE 8412 NLE 8412 NGMLE 8412 NMLE 8412 NGME 8412 NME 8412 NG 8412 N 8412 NH 8412 NH-217 8414 NGL 8414 NL 8414 NGML 8414 NML 8414 NGM 8414 NM 8414 NG 8414 N 8414 NH 8414 NH-221 8418 N 5 40 4 30 3 20 2 10 1 m3/h CFM VDC VDC dB(A) Bel(A) / 33 19,4 12 8...15 12 3,5 33 19,4 12 8...15 17 3,7 45 26,5 12 8...15 19 3,9 45 26,5 12 8...15 21 4,0 58 34,1 12 8...15 26 4,3 58 34,1 12 8...15 27 4,4 69 40,6 12 8...15 32 4,7 69 40,6 12 8...15 32 4,7 79 46,5 12 8...13,2 37 5,0 79 46,5 12 8...15 37 5,0 33 19,4 24 18...28 12 3,5 33 19,4 24 18...28 17 3,7 45 26,5 24 18...28 19 3,9 45 26,5 24 18...28 21 4,0 58 34,1 24 18...28 26 4,3 58 34,1 24 18...28 27 4,4 69 40,6 24 18...28 32 4,7 69 40,6 24 18...28 32 4,7 79 46,5 24 18...26 37 5,0 79 46,5 24 18...28 37 5,0 69 40,6 48 36...56 32 4,7 Watts 0,5 0,3 0,9 0,6 1,4 1,0 2,0 1,7 2,1 2,5 0,9 0,8 1,2 1,1 1,4 1,4 2,2 1,8 2,4 2,2 2,0 rpm 1 500 1 500 2 050 2 050 2 600 2 600 3 100 3 100 3 600 3 600 1 500 1 500 2 050 2 050 2 600 2 600 3 100 3 100 3 600 3 600 3 100 °C -20...+85 -20...+85 -20...+80 -20...+85 -20...+75 -20...+75 -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 Hours Hours 80 000 / 27 500 135 000 ➀ 80 000 / 27 500 135 000 ➀ 80 000 / 32 500 135 000 ➁ 80 000 / 27 500 135 000 ➁ 80 000 / 35 000 135 000 ➂ 80 000 / 35 000 135 000 ➂ 70 000 / 35 000 117 500 ➃ 70 000 / 35 000 117 500 ➃ 70 000 / 35 000 117 500 ➄ 70 000 / 35 000 117 500 ➄ 80 000 / 40 000 135 000 ➀ 80 000 / 40 000 135 000 ➀ 80 000 / 40 000 135 000 ➁ 80 000 / 40 000 135 000 ➁ 80 000 / 40 000 135 000 ➂ 80 000 / 40 000 135 000 ➂ 70 000 / 35 000 117 500 ➃ 70 000 / 35 000 117 500 ➃ 70 000 / 35 000 117 500 ➄ 70 000 / 35 000 117 500 ➄ 70 000 / 35 000 117 500 ➃ tin-plated 0 8 16 24 32 40 CFM 10 20 30 40 50 60 m³/h 44 Guard grilles from p. 238 Information DC axial fans DC centrifugal fans DC fans - specials 58 max. m3/h DC axial fans Series 8400 N VARIOFAN 80 x 80 x 25 mm – Material: Housing: GRP1) (PBT) Impeller: GRP1) (PA) – Direction of air flow: Exhaust over struts – Direction of rotation: Counter-clockwise, seen on rotor – Connection: Via single wires AWG 24, TR 64 – Highlights: Automatic speed adjustment with temperature sensor – Mass: 95 g – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - External temperature sensor - Internal temperature sensor - Protection against moisture 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type 30°C 50°C 8412 NGLV 30°C 8412 NGMLV 50°C 30°C 50°C 8412 NGMI Subject to alternations m3/h CFM VDC VDC dB(A) Bel(A) / 20 11,8 33 19,4 12 10...14 < 10 < 3 12 3,5 27 15,9 45 26,6 12 8...14 < 10 3,0 19 3,9 35 20,6 58 34,1 12 8...14 < 13 3,5 26 4,3 Watts 0,9 1,1 1,1 1,5 1,4 2,0 rpm 900 1 500 1 200 2 050 1 600 2 600 °C -20...+65 -20...+65 -20...+65 Hours Hours ➀ 80 000 / 45 000 135 000 ➁ ➂ 80 000 / 45 000 135 000 ➃ ➄ 80 000 / 45 000 135 000 ➅ Pa [in H O] 2 [in H O] 2 [in H O] 2 Pa 2 7,5 8412 NGLV 0,03 0,02 5 1 2,5 0,01 30°C 50°C 0 4 8 12 16 20 CFM 10 20 30 m³/h V-Types Pa 4 15 8412 NGMLV 0,06 0,04 10 0,02 5 3 30°C 50°C 0 5 10 15 20 25 CFM 10 20 30 40 m³/h 6 25 8412 NGMV 8412 NGMI 0,08 20 0,06 15 10 0,02 0,04 5 0 5 30°C 50°C 5 10 15 20 25 30 CFM 10 20 30 40 50 m³/h I-Types tin-plated ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Representatives The temperature sensor for controlling the motor speed is not included in delivery. Temperature sensor LZ 370 see accessories. Temperature sensor (NTC-resistor) for controlling the motor speed is positioned directly in the air flow. Guard grilles from p. 238 45 80 max. m3/h DC axial fans Series 8300 80 x 80 x 32 mm – Material: Housing: GRP1) (PBT) Impeller: GRP1) (PA) – Direction of air flow: Exhaust over struts – Direction of rotation: Clockwise, seen on rotor – Connection: Via single wires AWG 22, TR 64 – Mass: 170 g 1) Fibreglass-reinforced plastic – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Protection against moisture - Protection against fog - Type of protection: IP 54 / IP 68 Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type 8312 L 8312 M 8312 8312 HL 8312 H 8314 L 8314 M 8314 8314 HL 8314 H 8318 8318 HL 8318 H Subject to alternations m3/h CFM VDC VDC dB(A) Bel(A) / 32 18,8 12 6...15 24 4,0 48 28,3 12 6...15 34 5,0 54 31,8 12 6...15 36 5,2 67 39,4 12 6...15 43 5,8 80 47,1 12 6...12,6 48 6,2 32 18,8 24 12...31,5 24 4,0 48 28,3 24 12...31,5 34 5,0 54 31,8 24 12...31,5 36 5,2 67 39,4 24 12...31,5 43 5,8 80 47,1 24 12...28 48 6,2 54 31,8 48 36...60 36 5,2 67 39,4 48 36...60 43 5,8 80 47,1 48 36...60 48 6,2 Watts 1,2 2,2 2,6 4,0 6,4 1,0 2,3 2,7 4,3 6,0 3,0 4,2 6,2 rpm 2 000 3 000 3 300 4 200 5 000 2 000 3 000 3 300 4 200 5 000 3 300 4 200 5 000 °C -20...+75 -20...+75 -20...+75 -20...+75 -20...+60 -20...+75 -20...+75 -20...+75 -20...+75 -20...+75 -20...+75 -20...+75 -20...+65 Hours Hours 80 000 / 32 500 135 000 ➀ 70 000 / 27 500 117 500 ➁ 70 000 / 27 500 117 500 ➂ 62 500 / 25 000 105 000 ➃ 55 000 / 35 000 92 500 ➄ 80 000 / 32 500 135 000 ➀ 70 000 / 27 500 117 500 ➁ 70 000 / 27 500 117 500 ➂ 62 500 / 25 000 105 000 ➃ 55 000 / 22 500 92 500 ➄ 70 000 / 27 500 117 500 ➂ 62 500 / 25 000 105 000 ➃ 55 000 / 30 000 92 500 ➄ Pa [in H O] 2 120 5 0, 4 100 4 80 0, 3 60 3 0,2 40 2 0, 1 20 1 0 8 16 24 32 40 CFM 10 20 30 40 50 60 m³/h 46 Guard grilles from p. 238 Rotor protrusion max. 0,4 mm. tin-plated Information DC axial fans DC centrifugal fans max. 222 m3/h DC axial fans Series 8200 J 80 x 80 x 38 mm – Material: Housing: GRP1) (PBT) Impeller: GRP1) (PA) – Direction of air flow: Exhaust over struts – Direction of rotation: Counter-clockwise, seen on rotor – Connection: Via single wires AWG 24 (H3 and H4: AWG 22), TR 64 – Mass: 160 g (H3 and H4: 200 g) – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Protection against moisture - Type of protection: IP 54 / IP 68 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power* Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type 8212 JN 8212 JH3 8212 JH4 8214 JN 8214 JH3 8214 JH4 8218 JN 8218 JH3 8218 JH4 Subject to alternations m3/h CFM VDC VDC dB(A) Bel(A) / 132 78 12 7...13,8 55 6,6 190 112 12 6...13,8 66 7,3 222 131 12 6...13,8 71 7,8 132 78 24 18...26,4 55 6,6 190 112 24 12...27,6 66 7,3 222 131 24 12...27,6 71 7,8 132 78 48 36...53 55 6,6 190 112 48 36...53 66 7,3 222 131 48 20...58 71 7,8 Watts rpm 10 8400 26* 12 000 39* 14 000 11 8400 26* 12 000 38* 14 000 11 8400 25* 12 000 36* 14 000 °C -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 Hours Hours 62 500 / 32 500 105 000 ➀ 55 000 / 27 500 92 500 ➁ 50 000 / 25 000 85 000 ➂ 62 500 / 32 500 105 000 ➀ 55 000 / 27 500 92 500 ➁ 50 000 / 25 000 85 000 ➂ 62 500 / 32 500 105 000 ➀ 55 000 / 27 500 92 500 ➁ 50 000 / 25 000 85 000 ➂ 8200 JH3 and JH4 also available as standard with PWM control input and speed signal. Speed control range from 2000 rpm up to maximum nominal speed. Stationary at 0 % PWM, maximum speed at sensor break. * Input power at free air flow, these values can be significantly higher in the operating point. DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Pa [in H2O] Accessories 0,4 0,8 1,2 1 ,6 2,0 3 600 500 2 400 300 1 200 100 0 25 50 75 100 125 CFM 50 100 150 200 m³/h Guard grilles from p. 238 tin-plated 47 Representatives max. 102 m3/h DC axial fans Series 3400 N 92 x 92 x 25 mm – Material: Housing: GRP1) (PBT) Impeller: GRP1) (PA) – Direction of air flow: Exhaust over struts – Direction of rotation: Counter-clockwise, seen on rotor – Connection: Via single wires AWG 24, TR 64 – Mass: 100 g 1) Fibreglass-reinforced plastic – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Protection against moisture - Type of protection: IP 54 / IP 68 Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type m3/h CFM VDC VDC dB(A) Bel(A) / 3412 NGLE 3412 NLE 3412 NGME 3412 NME 3412 NG 3412 N 3412 NGH 3412 NH 3412 NGHH 3412 NHH 3412 NHH-379 61 35,9 61 35,9 72 42,4 72 42,4 84 49,4 84 49,4 94 55,3 94 55,3 102 60,0 102 60,0 102 60,0 3414 NGL 3414 NL 3414 NGM 3414 NM 3414 NG 3414 N 3414 NGH 3414 NH 3414 NGHH 3414 NGHH-389 3414 NHH 3414 NHH-386 61 35,9 61 35,9 72 42,4 72 42,4 84 49,4 84 49,4 94 55,3 94 55,3 102 60,0 102 60,0 102 60,0 102 60,0 3418 N 84 49,4 Other 48 VDC models on request. 12 8...15 12 8...15 12 8...15 12 8...15 12 8...15 12 8...15 12 8...15 12 8...15 12 8...13,2 12 8...13,2 12 8...15 24 18...28 24 18...28 24 18...28 24 18...28 24 18...28 24 18...28 24 18...26 24 18...26 24 18...26 24 18...28 24 18...26 24 18...28 48 36...56 23 4,0 23 4,0 28 4,3 28 4,3 32 4,7 32 4,7 36 5,0 36 5,0 39 5,1 39 5,1 39 5,1 23 4,0 23 4,0 28 4,3 28 4,3 32 4,7 32 4,7 36 5,0 36 5,0 39 5,1 39 5,1 39 5,1 39 5,1 32 4,7 [in H2O] Pa 5 0,15 40 4 30 3 0,10 2 20 1 10 0,05 Watts 1,1 0,8 1,6 1,1 1,9 1,7 2,3 2,1 3,2 2,9 2,7 1,4 1,1 1,7 1,4 2,5 2,1 3,0 2,3 3,2 3,2 3,1 3,2 2,4 rpm 1 950 1 950 2 300 2 300 2 700 2 700 3 000 3 000 3 250 3 250 3 250 1 950 1 950 2 300 2 300 2 700 2 700 3 000 3 000 3 250 3 250 3 250 3 250 2 700 °C -20...+80 -20...+85 -20...+75 -20...+75 -20...+70 -20...+70 -20...+70 -20...+70 -20...+60 -20...+60 -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 Hours Hours 80 000 / 22 500 135 000 ➀ 80 000 / 17 500 135 000 ➀ 75 000 / 27 500 127 500 ➁ 75 000 / 27 500 127 500 ➁ 70 000 / 35 000 117 500 ➂ 70 000 / 35 000 117 500 ➂ 70 000 / 35 000 117 500 ➃ 70 000 / 35 000 117 500 ➃ 70 000 / 45 000 127 500 ➄ 70 000 / 45 000 127 500 ➄ 70 000 / 35 000 117 500 ➄ 80 000 / 40 000 135 000 ➀ 80 000 / 40 000 135 000 ➀ 75 000 / 37 500 127 500 ➁ 75 000 / 37 500 127 500 ➁ 70 000 / 35 000 117 500 ➂ 70 000 / 35 000 117 500 ➂ 70 000 / 35 000 117 500 ➃ 70 000 / 35 000 117 500 ➃ 70 000 / 35 000 117 500 ➄ 70 000 / 35 000 117 500 ➄ 70 000 / 35 000 117 500 ➄ 70 000 / 35 000 117 500 ➄ 70 000 / 35 000 117 500 ➂ tin-plated 0 10 20 30 40 5 0 CFM 20 40 60 80 m³/h 48 Guard grilles from p. 238 Information DC axial fans 84 max. m3/h DC axial fans Series 3400 N VARIOFAN 92 x 92 x 25 mm – Material: Housing: GRP1) (PBT) Impeller: GRP1) (PA) – Direction of air flow: Exhaust over struts – Direction of rotation: Counter-clockwise, seen on rotor – Connection: Via single wires AWG 24, TR 64 – Highlights: Automatic speed adjustment with temperature sensor – Mass: 100 g – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - External temperature sensor - Internal temperature sensor - Protection against moisture 1) Fibreglass-reinforced plastic DC centrifugal fans Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans Nominal data Type 30°C 3412 NGMV 50°C 30°C 50°C 3412 NGV Subject to alternations m3/h CFM VDC VDC dB(A) Bel(A) / 44 25,9 72 42,4 12 8...14 14 3,5 28 4,3 50 29,4 84 49,4 12 8...12,6 16 3,7 32 4,7 Watts 1,5 2,0 1,6 2,5 rpm 1 400 2 300 1 600 2 700 °C -20...+65 -20...+65 Hours Hours ➀ 75 000 / 42 500 127 500 ➁ ➂ 75 000 / 42 500 127 500 ➃ 0,08 [in H2O] Pa Pa [in H2O] 2 20 3412 NGMV 0,06 15 0,04 10 1 5 0,02 30°C 50°C 0 8 16 24 32 40 CFM 10 20 30 40 50 60 m³/h The temperature sensor for controlling the motor speed is not included in delivery. Temperature sensor LZ 370 see accessories. 4 25 3412 NGV 0,02 0,04 0,06 0,08 20 15 10 3 5 30°C 50°C 0 8 16 24 32 40 CFM 10 20 30 40 50 60 70 m³/h Guard grilles from p. 238 tin-plated 49 AC centrifugal fans Accessories Representatives max. 107 m3/h DC axial fans Series 3300 92 x 92 x 32 mm – Material: Housing: GRP1) (PBT) Impeller: GRP1) (PA) – Direction of air flow: Exhaust over struts – Direction of rotation: Clockwise, seen on rotor – Connection: Via single wires AWG 22, TR 64 – Mass: 190 g 1) Fibreglass-reinforced plastic – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Protection against moisture - Protection against salt fog - Type of protection: IP 54 / IP 68 Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type 3312 L 3312 GM 3312 M 3312 3312-177 3314 G 3314 3314-140 3314 H 3318 3318 H Subject to alternations m3/h CFM VDC VDC dB(A) Bel(A) / 56 33,0 12 6...15 68 40,0 12 6...15 68 40,0 12 6...15 80 47,1 12 6...15 93 54,7 12 6...15 29 4,5 34 4,8 34 4,8 37 5,2 43 5,7 80 47,1 24 12...28 80 47,1 24 12...28 85 50,0 24 12...28 107 63,0 24 12...28 37 5,2 37 5,2 40 5,4 47 6,0 80 47,1 48 36...60 107 63,0 48 36...60 37 5,2 47 6,0 Watts 1,5 1,8 1,8 2,5 3,5 2,5 2,5 3,0 5,0 2,4 4,9 rpm 2 150 2 600 2 600 3 000 3 400 3 000 3 000 3 200 4 000 3 000 4 000 °C -20...+75 -20...+75 -20...+75 -20...+75 -20...+75 -20...+75 -20...+75 -20...+75 -20...+75 -20...+75 -20...+60 Hours Hours 80 000 / 35 000 135 000 ➀ 70 000 / 30 000 117 500 ➁ 70 000 / 30 000 117 500 ➁ 70 000 / 30 000 117 500 ➂ 65 000 / 27 500 110 000 ➄ 70 000 / 30 000 117 500 ➂ 70 000 / 30 000 117 500 ➂ 70 000 / 30 000 117 500 ➃ 57 500 / 25 000 97 500 ➅ 70 000 / 30 000 117 500 ➂ 57 500 / 32 500 97 500 ➅ [in H O] 2 Pa 6 70 5 0,25 60 4 50 3 0,20 0,15 40 2 0,10 30 1 20 0,05 10 0 10 20 30 40 50 6 0 CFM 20 40 60 80 100 m³/h 50 Guard grilles from p. 238 tin-plated Information DC axial fans DC centrifugal fans max. 133 m3/h DC axial fans Series 3300 N 92 x 92 x 32 mm – Material: Housing: GRP1) (PBT) Impeller: GRP1) (PA) – Direction of air flow: Exhaust over struts – Direction of rotation: Clockwise, seen on rotor – Connection: Via single wires AWG 24 UL 1061, TR 64 – Mass: 190 g 1) Fibreglass-reinforced plastic – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Protection against moisture - Protection against salt fog - Type of protection: IP 54 / IP 68 Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type 3312 NL 3312 NM 3312 NN 3312 NH 3312 NHH 3312 NH3 Subject to alternations m3/h CFM VDC VDC 56 33 12 6...15 68 40 12 6...15 80 47 12 6...15 93 54 12 6...15 107 63 12 6...15 133 78 12 6...15 dB(A) Bel(A) / 23 4,0 29 4,3 34 4,7 36,5 5,0 40 5,4 48 5,9 Watts 0,8 1,3 1,7 2,5 3,4 6,4 rpm 1 850 2 250 2 650 3 050 3 450 4 350 °C -20...+75 -20...+75 -20...+75 -20...+75 -20...+75 -20...+70 Hours Hours 80 000 / 35 000 135 000 ➀ 70 000 / 30 000 117 500 ➁ 70 000 / 30 000 117 500 ➂ 65 000 / 27 500 110 000 ➃ 57 500 / 25 000 97 500 ➄ 50 000 / 25 000 85 000 ➅ DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans 0,4 [in H2O] Pa Accessories 6 100 0,3 80 5 60 4 0,2 40 3 2 0,1 20 1 0 20 40 60 CFM 20 40 60 80 100 120 m³/h Guard grilles from p. 238 tin-plated Ø 100,1 ± 0,3 51 Representatives max. 280 m3/h DC axial fans Series 3200 J 92 x 92 x 38 mm – Material: Housing: GRP1) (PBT) Impeller: GRP1) (PA) – Direction of air flow: Exhaust over struts – Direction of rotation: Clockwise, seen on rotor – Connection: Via single wires AWG 24 (H3 and H4: AWG 22), TR 64 – Mass: 240 g (H3 and H4: 280 g) – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Protection against moisture - Type of protection: IP 54 / IP 68 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power* Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type 3212 JN 3212 JH 3212 JH3 3212 JH4 3214 JN 3214 JH 3214 JH3 3214 JH4 3218 JN 3218 JH 3218 JH3 3218 JH4 Subject to alternations m3/h CFM VDC VDC dB(A) Bel(A) / 130 76,5 146 86,0 237 139,5 280 164,8 12 7...13,8 12 7...15 12 6...13,8 12 6...13,8 51 6,1 55 6,4 69 7,8 73 8,2 130 76,5 24 11...28 51 6,1 146 86,0 24 12...30 55 6,4 237 139,5 24 12...27,6 69 7,8 280 164,8 24 12...27,6 73 8,2 130 76,5 48 36...56 51 6,1 146 86,0 48 36...53 55 6,4 237 139,5 48 20...58,0 69 7,8 280 164,8 48 20...58,0 73 8,2 Watts rpm 7,5 9,0 31,0* 50,0* 6 000 6 800 11 000 13 000 6,5 9,0 30,0* 50,0* 6 000 6 800 11 000 13 000 7,0 9,5 29,0* 50,0* 6 000 6 800 11 000 13 000 °C -20 ...+70 -20 ...+70 -20 ...+70 -20 ...+70 -20 ...+70 -20 ...+70 -20 ...+70 -20 ...+70 -20 ...+70 -20 ...+70 -20 ...+70 -20 ...+70 Hours Hours 70 000 / 35 000 117 500 ➀ 70 000 / 35 000 117 500 ➁ 65 000 / 32 500 110 000 ➂ 60 000 / 30 000 110 000 ➃ 70 000 / 35 000 117 500 ➀ 70 000 / 35 000 117 500 ➁ 65 000 / 32 500 110 000 ➂ 60 000 / 30 000 110 000 ➃ 70 000 / 35 000 117 500 ➀ 70 000 / 35 000 117 500 ➁ 65 000 / 32 500 110 000 ➂ 60 000 / 30 000 110 000 ➃ 3200 JH3 and JH4 also available as standard with PWM control input and speed signal. Speed control range from 2000 rpm up to maximum nominal speed. Stationary at 0 % PWM, maximum speed at sensor break. * Input power at free air flow, these values can be significantly higher in the operating point. tin-plated 52 Guard grilles from p. 238 Information DC axial fans DC centrifugal fans max. 270 m3/h DC axial fans Series 3250 J 92 x 92 x 38 mm – Material: Housing: GRP1) (PBT) Impeller: GRP1) (PA) – Direction of air flow: Exhaust over struts – Direction of rotation: Clockwise, seen on rotor – Connection: Via single wires AWG 22, TR 64 – Mass: 240 g 1) Fibreglass-reinforced plastic – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Protection against moisture - Protection against salt fog - Type of protection: IP 54 / IP 68 Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power* Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type 3258 JHP 3258 JHHP 3258 JH3P Subject to alternations m3/h CFM VDC VDC dB(A) Bel(A) / Watts rpm °C 145 85 48 36...56 47 5,8 235 138 48 36...56 59 7,2 270 158 48 36...56 63 7,7 5,3 4 100 -20...+70 22,6 6 650 -20...+70 34,3 7 600 -20...+70 12 V and 24 V variants also available on request. * Input power at free air flow, these values can be significantly higher in the operating point. Hours Hours 85 000 / 42 500 142 500 ➀ 80 000 / 40 000 135 000 ➁ 75 000 / 37 500 127 500 ➂ DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Guard grilles from p. 238 tin-plated 53 Representatives max. 170 m3/h DC axial fans Series 4400 F 119 x 119 x 25 mm – Material: Housing: GRP1) (PBT) Impeller: GRP1) (PA) – Direction of air flow: Exhaust over struts – Direction of rotation: Counter-clockwise, seen on rotor – Connection: Via single wires AWG 24, TR 64 – Highlights: Ball bearings and plain bearings available – Mass: 175 g – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Protection against moisture 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type 4412 FGL 4412 FGML 4412 FML 4412 FGM 4412 FM 4412 FG 4412 F 4414 FL 4414 FM 4414 FG 4414 F 4418 FG 4418 F Subject to alternations m3/h CFM VDC VDC dB(A) Bel(A) / 94 55 12 7...14 26 3,9 114 67 12 7...12,6 32 4,3 114 67 12 7...12,6 32 4,3 140 82 12 7...12,6 38 4,8 140 82 12 7...12,6 38 4,8 170 100 12 8...12,6 43 5,3 170 100 12 8...12,6 43 5,3 94 55 24 18...28 26 3,9 140 82 24 12...28 38 4,8 170 100 24 12...28 43 5,3 170 100 24 12...28 43 5,3 170 100 48 28...53 43 5,3 170 100 48 28...53 43 5,3 Watts 1,3 2,0 2,0 3,2 3,2 5,3 5,3 1,2 3,1 5,0 5,0 5,4 5,4 rpm 1 600 1 950 1 950 2 400 2 400 2 900 2 900 1 600 2 400 2 900 2 900 2 900 2 900 °C -20...+75 -20...+75 -20...+75 -20...+75 -20...+75 -20...+60 -20...+60 -20...+75 -20...+75 -20...+60 -20...+60 -20...+60 -20...+60 Hours Hours 80 000 / 35 000 135 000 ➀ 75 000 / 32 500 127 500 ➁ 75 000 / 32 500 127 500 ➁ 70 000 / 30 000 117 500 ➂ 70 000 / 30 000 117 500 ➂ 60 000 / 37 500 102 500 ➃ 60 000 / 37 500 102 500 ➃ 80 000 / 35 000 135 000 ➀ 70 000 / 30 000 117 500 ➂ 60 000 / 37 500 102 500 ➃ 60 000 / 37 500 102 500 ➃ 60 000 / 37 500 102 500 ➃ 60 000 / 37 500 102 500 ➃ Available on request: Fan housing with moulded-in spacers. For mounting over both flanges. Pa [in H2O] 4 50 40 3 0,15 30 2 0,10 20 1 0,05 10 0 15 30 45 60 75 9 0 CFM 25 50 75 100 125 m³/h 54 Guard grilles from p. 238 tin-plated Information DC axial fans DC centrifugal fans max. 225 m3/h DC axial fans Series 4400 FN 119 x 119 x 25 mm – Material: Housing: GRP1) (PBT) Impeller: GRP1) (PA) – Direction of air flow: Exhaust over struts – Direction of rotation: Counter-clockwise, seen on rotor – Connection: Via single wires AWG 22, TR 64 – Mass: 240 g – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Protection against moisture 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type 4412 FNH 4414 FNN 4414 FNH 4418 FNH Subject to alternations m3/h CFM VDC VDC dB(A) Bel(A) / 225 132 12 9...13,2 55 6,7 200 118 24 14...28 52 6,5 225 132 24 18...26,4 55 6,7 225 132 48 36...53 55 6,7 Watts 12 8,3 12 12 rpm 5 400 4 850 5 400 5 400 °C -20...+70 -20...+70 -20...+70 -20...+70 Hours Hours 60 000 / 30 000 102 500 ➁ 60 000 / 30 000 102 500 ➀ 60 000 / 30 000 102 500 ➁ 60 000 / 30 000 102 500 ➁ DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Pa [in H2O] Accessories 0,1 0,2 0,3 0,4 0,5 0,6 175 2 150 1 125 100 75 50 25 0 20 40 60 80 100 120 CFM 50 100 150 200 m³/h tin-plated Guard grilles from p. 238 55 Representatives max. 204 m3/h DC axial fans Series 4300 119 x 119 x 32 mm – Material: Housing: GRP1) (PBT) Impeller: GRP1) (PA) – Direction of air flow: Exhaust over struts – Direction of rotation: Clockwise, seen on rotor – Connection: Via single wires AWG 22, TR 64 – Highlights: Ball bearings and plain bearings available – Mass: 220 g 1) Fibreglass-reinforced plastic – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Protection against moisture - Protection against salt fog - Type of protection: IP 54 / IP 68 Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type 4312 GL 4312 L 4312 GM 4312 M 4312 G 4312 4312-179 4314 L 4314 M 4314 G 4314 4314-147 4314-180 4318 M 4318 Subject to alternations m3/h CFM VDC VDC dB(A) Bel(A) / 95 56 12 6...15 30 4,3 95 56 12 6...15 30 4,3 140 82 12 6...15 39 5,3 140 82 12 6...15 39 5,3 170 100 12 6...15 45 5,8 170 100 12 6...15 45 5,8 204 120 12 6...13,2 51 6,4 95 56 140 82 170 100 170 100 180 106 204 120 24 12...28 24 12...28 24 12...28 24 12...28 24 12...28 24 12...26 30 4,3 39 5,3 45 5,8 45 5,8 47 6,1 51 6,4 140 82 170 100 48 36...56 48 36...53 39 5,3 45 5,8 Watts 1,2 1,2 3,1 3,1 5,0 5,0 9,4 1,2 2,8 4,7 5,0 4,7 8,5 3,6 5,1 rpm 1 550 1 550 2 300 2 300 2 800 2 800 3 400 1 550 2 300 2 800 2 800 3 000 3 400 2 300 2 800 °C -20...+75 -20...+75 -20...+75 -20...+75 -20...+70 -20...+70 -20...+65 -20...+75 -20...+75 -20...+75 -20...+75 -20...+75 -20...+70 -20...+75 -20...+75 Hours Hours 80 000 / 35 000 135 000 ➀ 80 000 / 35 000 135 000 ➀ 70 000 / 30 000 117 500 ➁ 70 000 / 30 000 117 500 ➁ 62 500 / 30 000 105 000 ➂ 62 500 / 30 000 105 000 ➂ 47 500 / 27 500 80 000 ➄ 80 000 / 35 000 135 000 ➀ 70 000 / 30 000 117 500 ➁ 62 500 / 27 500 105 000 ➂ 62 500 / 27 500 105 000 ➂ 57 500 / 25 000 80 000 ➃ 45 000 / 22 500 75 000 ➄ 70 000 / 30 000 117 500 ➁ 62 500 / 27 500 105 000 ➂ Pa [in H2O] 5 80 4 0, 3 60 3 0, 2 40 2 0,1 20 1 0 15 30 45 60 75 90 CFM 25 50 75 100 125 150 m³/h 56 Guard grilles from p. 238 Rotor protrusion max. 0.4 mm. tin-plated Information DC axial fans max. 170 m3/h DC axial fans Series 4300 VARIOFAN 119 x 119 x 32 mm – Material: Housing: GRP1) (PBT) Impeller: GRP1) (PA) – Direction of air flow: Exhaust over struts – Direction of rotation: Clockwise, seen on rotor – Connection: Via single wires AWG 22, TR 64 – Highlights: Speed automatically adjusted to cooling requirement – Mass: 220 g – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Protection against moisture 1) Fibreglass-reinforced plastic DC centrifugal fans Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans Nominal data Type 25°C 4312 MT 50°C 25°C 4312 T 50°C 30°C 50°C 4314 T Subject to alternations m3/h CFM VDC VDC dB(A) Bel(A) / 65 38 12 8...15 138 81 25 3,9 39 5,3 85 50 170 100 12 8...13,2 29 4,2 45 5,8 85 50 170 100 24 18...32 29 4,2 45 5,8 Watts 1,1 3,3 1,7 5,0 1,6 4,8 rpm 1 100 2 300 1 400 2 800 1 400 2 800 °C -20...+65 -20...+65 -20...+65 Hours Hours ➀ 70 000 / 40 000 117 500 ➁ ➂ 65 000 / 35 000 110 000 ➃ ➂ 65 000 / 35 000 110 000 ➃ [in H2O] Pa 2 40 4312 MV 0,15 30 0,10 20 0,05 10 1 25°C 50°C 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 CFM 20 40 60 80 100 m³/h 4 60 4312 T 4314 V 0,20 50 40 0,15 30 0,10 20 3 10 0,05 0 15 25 25 °C / 30°C 30 45 60 75 50 75 100 125 50°C 9 0 CFM m³/h The temperature sensor for controlling the motor speed is not included in delivery. Temperature sensor LZ 370 see accessories. Rotor protrusion max. 0.4 mm. tin-plated Pa [in H O] 2 Guard grilles from p. 238 57 AC centrifugal fans Accessories Representatives max. 205 m3/h DC axial fans Series 4400 119 x 119 x 38 mm – Material: Housing: GRP1) (PBT) Impeller: GRP1) (PA) – Direction of air flow: Exhaust over struts – Direction of rotation: Clockwise, seen on rotor – Connection: Via single wires AWG 24, TR 64 – Mass: 270 g 1) Fibreglass-reinforced plastic – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Protection against moisture - Type of protection: IP 54 Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type m3/h CFM VDC VDC 4412 L 4412 ML 4412 M 4412 N 150 88 12 7...14 168 99 12 7...15 184 108 12 7...14 205 121 12 7...14 4414 L3 4414 LL 4414 L 4414 ML 4414 M 4414 N 100 59 24 12...28 124 73 24 12...28 150 88 24 18...28 168 99 24 12...28 184 108 24 18...28 205 121 24 18...28 4418 L 4418 ML 4418 M 4418 N Subject to alternations 150 88 48 36...60 168 99 48 36...60 184 108 48 36...60 205 121 48 36...60 Further variants can be found on page 59. dB(A) Bel(A) / 37 5,0 40 5,1 42 5,3 46 5,6 26 4,0 33 4,5 37 5,0 40 5,1 42 5,3 46 5,6 37 5,0 40 5,1 42 5,3 46 5,6 Watts 2,2 3,0 3,8 5,3 1,0 1,6 2,4 3,2 4,1 5,4 2,5 3,2 4,2 5,4 rpm 2 700 3 000 3 300 3 650 1 800 2 250 2 700 3 000 3 300 3 650 2 700 3 000 3 300 3 650 °C -20...+80 -20...+80 -20...+75 -20...+70 -20...+80 -20...+80 -20...+80 -20...+80 -20...+75 -20...+70 -20...+75 -20...+75 -20...+70 -20...+70 Hours Hours 67 500 / 22 500 115 000 ➂ 67 500 / 22 500 115 000 ➃ 65 000 / 25 000 110 000 ➄ 62 500 / 30 000 105 000 ➅ 75 500 / 22 500 127 500 ➀ 70 000 / 22 500 117 500 ➁ 67 500 / 22 500 115 000 ➂ 67 500 / 22 500 115 000 ➃ 65 000 / 25 000 110 000 ➄ 62 500 / 30 000 105 000 ➅ 67 500 / 27 500 115 000 ➂ 67 500 / 27 500 115 000 ➃ 65 000 / 32 500 110 000 ➄ 62 500 / 30 000 105 000 ➅ tin-plated 58 Guard grilles from p. 238 Information DC axial fans DC centrifugal fans max. 285 m3/h DC axial fans Series 4400 119 x 119 x 38 mm – Material: Housing: GRP1) (PBT) Impeller: GRP1) (PA) – Direction of air flow: Exhaust over struts – Direction of rotation: Clockwise, seen on rotor – Connection: Via single wires AWG 24, TR 64 – Mass: 270 g 1) Fibreglass-reinforced plastic – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Protection against moisture - Type of protection: IP 54 Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type 4412 H 4412/2 HHP 4414 H 4414 HH 4414/2 HHP 4418 H 4418/2 HHP Subject to alternations m3/h CFM VDC VDC dB(A) Bel(A) / 240 141 12 7...14 50 6,0 285 168 12 7...14,5 55 6,4 240 141 24 18...28 50 6,0 285 165 24 16...28 55 6,4 285 168 24 18...28 55 6,4 240 141 48 36...60 50 6,0 285 168 48 36...60 55 6,4 Watts 8,6 13,0 8,6 14,0 12,0 8,6 13,0 rpm 4 300 5 000 4 300 5 000 5 000 4 300 5 000 °C -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 Hours 57 500 / 27 500 50 000 / 25 000 57 500 / 27 500 50 000 / 25 000 50 000 / 25 000 57 500 / 27 500 50 000 / 25 000 Hours 92 500 ➀ 85 000 ➁ 92 500 ➀ 85 000 ➁ 85 000 ➁ 92 500 ➀ 85 000 ➁ DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Guard grilles from p. 238 tin-plated 59 Representatives max. 237 m3/h DC axial fans Series 4100 N 119 x 119 x 38 mm – Material: Housing: Die-cast aluminium – Possible special versions: Impeller: GRP1) (PA) (See chapter DC fans - specials) – Direction of air flow: Intake over struts - Speed signal – Direction of rotation: Clockwise, seen on rotor - Go / No-go alarm – Connection: On flat connectors, 2.8 x 0.5 mm - Alarm with limit speed Also available with wires as - External temperature sensor an option - Internal temperature sensor – Highlights: Housing with grounding lug for - PWM control input screw M4 x 8 (Torx) - Analogue control input – Mass: 390 g - Protection against moisture - Protection against salt fog - Type of protection: IP 54 / IP 68 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type 4182 NGX 4182 NX 4182 NXH 4184 NGX 4184 NXM 4184 NX 4184 NXH 4188 NGX 4188 NXM Subject to alternations m3/h CFM VDC VDC dB(A) Bel(A) / 160 94 12 6...15 180 106 12 6...15 237 140 12 7...14 44 5,3 49 5,7 57 6,5 160 94 24 12...31,5 44 5,3 160 94 24 12...31,5 44 5,3 180 106 24 12...31,5 49 5,7 237 140 24 12...28 57 6,5 160 94 48 36...60 44 5,3 160 94 48 36...60 44 5,3 Watts 3,7 4,9 11,0 3,3 3,2 4,9 11,0 3,6 3,5 rpm 2 800 3 200 4 400 2 800 2 800 3 200 4 400 2 800 2 800 °C -20...+75 -30...+75 -30...+55 -20...+75 -30...+75 -30...+70 -30...+70 -20...+75 -30...+75 Hours Hours 85 000 / 37 500 142 500 ➀ 85 000 / 37 500 142 500 ➁ 70 000 / 50 000 117 500 ➂ 85 000 / 37 500 142 500 ➀ 85 000 / 37 500 142 500 ➀ 85 000 / 42 500 142 500 ➁ 70 000 / 35 000 117 500 ➂ 85 000 / 37 500 142 500 ➀ 85 000 / 37 500 142 500 ➀ [in H O] 2 Pa 3 140 0, 5 120 0,4 100 2 80 0,3 60 1 0, 2 40 0, 1 20 0 20 40 60 80 100 120 CFM 40 80 120 160 200 m³/h 60 Guard grilles from p. 238 Connection cables from p. 251 Information DC axial fans DC centrifugal fans max. 440 m3/h DC axial fans Series 4100 N High Performance 119 x 119 x 38 mm – Material: Housing: Die-cast aluminium – Possible special versions: Impeller: GRP1) (PA) (See chapter DC fans - specials) – Direction of air flow: Intake over struts - Speed signal – Direction of rotation: Clockwise, seen on rotor - Go / No-go alarm – Connection: Via single wires AWG 22 UL - Alarm with limit speed 1007, TR 64 - External temperature sensor – Highlights: Housing with grounding lug for - Internal temperature sensor screw M4 x 8 (Torx) - PWM control input – Mass: 390 g - Analogue control input - Protection against moisture - Protection against salt fog - Type of protection: IP 54 / IP 68 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power* Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type 4112 NHH 4112 NH3 4112 NH4 4114 NHH 4114 NH3 4114 NH4 4114 NH5 4114 NH6 4118 NHH 4118 NH3 4118 NH4 4118 NH5 4118 NH6 Subject to alternations m3/h CFM VDC VDC dB(A) Bel(A) / Watts rpm °C 260 153 12 9...15 310 182 12 9...15 355 209 12 9...14 60 6,8 65 7,2 67 7,4 13,3 5 000 -20...+65 21,6 6 000 -20...+65 32,0 6 800 -20...+65 260 153 24 16...30 60 6,8 310 182 24 16...30 65 7,2 355 209 24 16...30 67 7,4 390 230 24 16...30 70 7,6 440 259 24 16...30 73 8,1 12,4 19,5 30,0 45,0* 65,0* 5 000 6 000 6 800 7 500 8 400 -20...+65 -20...+65 -20...+65 -20...+65 -20...+65 260 153 48 36...60 60 6,8 310 182 48 36...60 65 7,2 355 209 48 36...60 67 7,4 390 230 48 36...60 70 7,6 440 259 48 36...60 73 8,1 12,0 20,0 28,0 45,0* 62,0* 5 000 6 000 6 800 7 500 8 400 -20...+65 -20...+65 -20...+65 -20...+65 -20...+65 * Input power at free air flow, these values can be significantly higher in the operating point. Hours Hours 70 000 / 55 000 117 500 ➀ 65 000 / 37 500 110 000 ➁ 62 500 / 35 000 105 000 ➂ 70 000 / 52 500 117 500 ➀ 65 000 / 37 500 110 000 ➁ 62 500 / 35 000 105 000 ➂ 62 500 / 35 000 105 000 ➃ 60 000 / 32 500 102 500 ➄ 70 000 / 52 500 117 500 ➀ 65 000 / 37 500 110 000 ➁ 62 500 / 35 000 105 000 ➂ 62 500 / 35 000 105 000 ➃ 60 000 / 32 500 102 500 ➄ DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories tin-plated * Input power - in operation Fan type 4114 NH5 optimum operating range (W) 55 4114 NH6 95 4118 NH5 55 4118 NH6 95 Guard grilles from p. 238 61 Representatives max. 570 m3/h DC axial fans Series 4100 N High Performance 119 x 119 x 38 mm – Material: Housing: Die-cast aluminium – Possible special versions: Impeller: GRP1) (PA) (See chapter DC fans - specials) – Direction of air flow: Intake over struts - Speed signal – Direction of rotation: Clockwise, seen on rotor - Go / No-go alarm – Connection: Via single wires AWG 18, 20 or - Alarm with limit speed AWG 22, TR 64, speed signal - External temperature sensor and control input AWG 22 - Internal temperature sensor – Highlights: 3-phase fan drive with very - PWM control input smooth running and high - Analogue control input efficiency - Protection against moisture Housing with grounding lug for - Protection against salt fog screw M4 x 8 (Torx) – Mass: 425 g 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power** Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type 4114 N/2H7P 4114 N/2H8P 4118 N/2H7P 4118 N/2H8P Subject to alternations m3/h CFM VDC VDC dB(A) Bel(A) / 500 294 24 16...30 76 8,5 570 336 24 16...30 78 8,9 500 294 48 36...60* 76 8,5 570 336 48 36...60* 78 8,9 * 36...72 VDC on request. Watts rpm 90 9 500 120 11 000 90 9 500 120 11 000 °C -20...+75 -20...+75 -20...+75 -20...+75 Hours 57 500 / 25 000 55 000 / 22 500 57 500 / 25 000 55 000 / 22 500 Hours 97 500 ➀ 92 500 ➁ 97 500 ➀ 92 500 ➁ Speed control range from 500 rpm up to maximum nominal speed. Stationary at 0 % PWM, maximum speed at sensor break. To attain the specified service life, an external capacitor must be wired between the plus and minus strands. Please note the wiring suggestion on page 16. ** Input power at free air flow, these values can be significantly higher in the operating point. Pa [in H2O] 0,8 1,6 2,4 3,2 4,0 2 1200 1000 1 800 600 400 200 0 50 100 150 200 250 300 CFM 100 200 300 400 500 m³/h tin-plated ** Input power - in operation Fan type 4114 NH7P optimum operating range (W) 100 4114 NH8P 160 4118 NH7P 100 4118 NH8P 160 62 Guard grilles from p. 238 Information DC axial fans DC centrifugal fans max. 280 m3/h DC diagonal fans Series DV 4100 119 x 119 x 38 mm – Material: Housing: GRP1) (PBT) – Possible special versions: Available in Die-cast aluminium (See chapter DC fans - specials) Impeller: GRP1) (PA) - Speed signal – Direction of air flow: Exhaust over struts - Go / No-go alarm – Direction of rotation: Counter-clockwise, seen - Alarm with limit speed on rotor - External temperature sensor – Connection: Via single wires AWG 22, - Internal temperature sensor TR 64 - PWM control input – Highlights: Housing with grounding lug for - Analogue control input screw M4 x 8 (Torx) - Protection against moisture – Mass: 375 g - Protection against salt fog (with metal housing: 455 g) - Type of protection: IP 54 / IP 68 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power* Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type DV 4112 N DV 4114 N DV 4118 N Subject to alternations m3/h CFM VDC VDC dB(A) Bel(A) / Watts rpm °C 280 165 12 9...15 61 6,9 21,0 6 000 -20...+65 280 165 24 16...30 61 6,9 20,5 6 000 -20...+65 280 165 48 36...60 61 6,9 20,0 6 000 -20...+65 * Input power at free air flow, these values can be significantly higher in the operating point. Hours Hours 70 000 / 40 000 117 500 ➀ 70 000 / 40 000 117 500 ➀ 70 000 / 40 000 117 500 ➀ DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Pa [in H O] 2 Accessories 0,2 0,4 0,6 0,8 1,0 1 300 250 200 150 100 50 0 30 60 90 120 150 CFM 50 100 150 200 250 m³/h Guard grilles from p. 238 tin-plated 63 Representatives max. 340 m3/h DC axial fans Series 5200 N 127 x 127 x 38 mm – Material: Housing: GRP1) (PBT) Impeller: GRP1) (PA) – Direction of air flow: Exhaust over struts – Direction of rotation: Counter-clockwise, seen on rotor – Connection: Via single wires AWG 22, TR 64 – Mass: 310 g 1) Fibreglass-reinforced plastic – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Protection against moisture - Protection against salt fog - Type of protection: IP 54 / IP 68 Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power** Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type 5212 NM 5212 NN 5212 NH 5212 NHH* 5214 NM 5214 NN 5214 NH 5214 NHH* 5218 NM 5218 NN 5218 NH 5218 NHH* Subject to alternations m3/h CFM VDC VDC dB(A) Bel(A) / Watts rpm °C 187 110 12 7...14,5 43 5,3 216 127 12 7...14 46 5,6 252 148 12 7...14 51 6,0 340 200 12 9...15 58 6,6 4,1 2 750 -20...+75 6,2 3 150 -20...+70 9,8 3 650 -20...+70 19,0 4 900 -20...+65 187 110 24 12...28 43 5,3 216 127 24 12...28 46 5,6 252 148 24 12...28 51 6,0 340 200 24 16...30 58 6,6 4,6 2 750 -20...+75 6,0 3 150 -20...+75 9,8 3 650 -20...+70 17,5 4 900 -20...+65 187 110 48 36...56 43 5,3 216 127 48 36...56 46 5,6 252 148 48 36...56 51 6,0 340 200 48 36...60 58 6,6 4,5 2 750 -20...+75 6,2 3 150 -20...+70 9,6 3 650 -20...+55 18,0 4 900 -20...+65 ** Input power at free air flow, these values can be significantly higher in the operating point. Hours Hours 62 500 / 27 500 105 000 ➀ 57 500 / 25 000 97 500 ➁ 45 000 / 22 500 75 000 ➂ 45 000 / 25 000 75 000 ➃ 62 500 / 27 500 105 000 ➀ 57 500 / 25 000 97 500 ➁ 45 000 / 22 500 75 000 ➂ 45 000 / 25 000 75 000 ➃ 62 500 / 27 500 105 000 ➀ 57 500 / 32 500 97 500 ➁ 45 000 / 32 500 75 000 ➂ 45 000 / 25 000 75 000 ➃ *Models NHH: Fan housing with moulded-in spacers. 0,8 [in H2O] Pa 200 4 0, 6 150 0, 4 100 3 2 50 1 0, 2 0 40 80 120 160 200 CFM 100 200 300 m³/h 64 Guard grilles from p. 238 tin-plated Information DC axial fans DC centrifugal fans max. 320 m3/h DC diagonal fans Series DV 5200 127 x 127 x 38 mm – Material: Housing: GRP1) (PBT) – Possible special versions: Available in Die-cast aluminium (See chapter DC fans - specials) Metal flange - Speed signal Impeller: GRP1) (PA) - Go / No-go alarm – Direction of air flow: Exhaust over struts - Alarm with limit speed – Direction of rotation: Counter-clockwise, seen - External temperature sensor on rotor - Internal temperature sensor – Connection: Via single wires AWG 22, - PWM control input TR 64 - Analogue control input – Highlights: Housing with grounding lug for - Protection against moisture screw M4 x 8 (Torx) - Protection against salt fog – Mass: 415 g (with metal housing: 490 g) - Type of protection: IP 54 / IP 68 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power* Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type m3/h CFM VDC VDC dB(A) Bel(A) / Watts rpm °C DV 5212 N 270 159 12 9...15 56 6,4 21,0 5 000 -20...+65 DV 5214 N 270 159 24 16...30 56 6,4 20,4 5 000 -20...+65 DV 5218 N 270 159 48 36...60 56 6,4 18,5 5 000 -20...+65 Model comes standard with speed signal and PWM control input. Other versions by request. DV 5214/2 HP Subject to alternations 320 188 24 16...30 62 7,2 38,5 6 000 -20...+65 Speed control range from 1000 rpm up to maximum nominal speed. Stationary at 0 % PWM, maximum speed at sensor break. * Input power at free air flow, these values can be significantly higher in the operating point. Hours Hours 70 000 / 40 000 117 500 ➀ 70 000 / 40 000 117 500 ➀ 70 000 / 40 000 117500 ➀ 62 500 / 35 000 105 000 ➁ DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans [in H O] 2 Pa Accessories 1, 6 1, 2 2 400 300 1 200 100 0, 8 0, 4 0 25 50 75 100 125 150 175 CFM 50 100 150 200 250 m³/h Guard grilles from p. 238 tin-plated 65 Representatives max. 260 m3/h DC axial fans Series 5100 N 135 x 135 x 38 mm – Material: Housing: Die-cast aluminium – Possible special versions: Impeller: Painted sheet steel (See chapter DC fans - specials) – Direction of air flow: Exhaust over struts - Speed signal – Direction of rotation: Counter-clockwise, seen - Go / No-go alarm on rotor - Alarm with limit speed – Connection: Via single wires AWG 22, - External temperature sensor TR 64 - Internal temperature sensor – Highlights: Housing with grounding lug for - PWM control input screw M4 x 8 (Torx) - Analogue control input 48 V version incl. screws - Protection against moisture – Mass: 650 g - Protection against salt fog - Type of protection: IP 54 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power* Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type 5112 N 5114 N 5118 N Subject to alternations m3/h CFM VDC VDC dB(A) Bel(A) / Watts rpm °C 260 153 12 6...15 48 6,1 9,5 2 900 -25...+72 260 153 24 12...30 48 6,1 9,5 2 900 -25...+72 260 153 48 24...60 48 6,1 9,5 2 900 -25...+72 * Input power at free air flow, these values can be significantly higher in the operating point. Hours Hours 80 000 / 37 500 135 000 ➀ 80 000 / 37 500 135 000 ➀ 80 000 / 37 500 135 000 ➀ [in H O] 2 Pa 0, 3 1 80 60 40 20 0, 2 0,1 0 25 50 75 100 125 CFM 50 100 150 200 m³/h 66 Guard grilles from p. 238 tin-plated Information DC axial fans DC centrifugal fans max. 340 m3/h DC axial fans Series 5300 140 x 140 x 51 mm – Material: Housing: Die-cast aluminium – Possible special versions: Impeller: GRP1) (PA) (See chapter DC fans - specials) – Direction of air flow: Intake over struts - Speed signal – Direction of rotation: Counter-clockwise, seen - Go / No-go alarm on rotor - Alarm with limit speed – Connection: Via single wires AWG 22, - External temperature sensor TR 64 - Internal temperature sensor – Highlights: Housing with grounding lug for - PWM control input screw M4 x 8 (Torx) - Analogue control input – Mass: 900 g - Protection against moisture - Protection against salt fog - Type of protection: IP 54 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power* Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type 5314/2 HP 5318/2 HP Subject to alternations m3/h CFM VDC VDC dB(A) Bel(A) / 340 200 24 16...28 64 7,2 340 200 48 36...72 64 7,2 Watts 28,4 27 rpm 5 000 5 000 °C -20...+65 -20...+65 Speed control range from 700 rpm up to maximum nominal speed. Stationary at 0 % PWM, maximum speed at sensor break. * Input power at free air flow, these values can be significantly higher in the operating point. Hours Hours 77 500 / 40 000 130 000 ➀ 77 500 / 40 000 130 000 ➀ DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Pa [in H O] 2 Accessories 0,2 0,4 0,6 0,8 1,0 1 300 250 200 150 100 50 0 25 50 75 100 125 150 175 CFM 50 100 150 200 250 m³/h Guard grilles from p. 238 tin-plated 67 Representatives max. 670 m3/h DC axial fans Series 5300 TD 140 x 140 x 51 mm – Material: Housing: Die-cast aluminium Impeller: GRP1) (PA) – Direction of air flow: Intake over struts – Direction of rotation: Counter-clockwise, seen on rotor – Connection: Via single wires AWG 20 and AWG 22, TR 64 – Highlights: 3-phase fan drive with very smooth running and high efficiency – Mass: 900 g 1) Fibreglass-reinforced plastic – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Multi-option control input - Protection against moisture - Protection against salt fog - Type of protection: IP 54 / IP 68 Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power* Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type 5312/2 TDHP 5314/2 TDHP 5314/2 TDHHP 5318/2 TDHP 5318/2 TDHHP 5318/2 TDH4P Subject to alternations m3/h CFM VDC VDC dB(A) Bel(A) / 410 241 12 8...16 70 7,7 410 241 24 16...36 70 7,7 490 288 24 16...36 75 8,1 410 241 48 36...72 70 7,7 490 288 48 36...72 75 8,1 670 394 48 36...72 79 8,8 Watts 43 42 67 42 66 149 rpm 6 000 6 000 7 000 6 000 7 000 9 200 °C -20...+70 -20...+70 -20...+70 -20...+70 -20...+70 -20...+65 Speed control range from 1000 rpm up to maximum nominal speed. Stationary at 0 % PWM, maximum speed at sensor break. * Input power at free air flow, these values can be significantly higher in the operating point. Hours Hours 70 000 / 35 000 117 500 ➀ 70 000 / 35 000 117 500 ➀ 62 500 / 30 000 105 000 ➁ 70 000 / 35 000 117 500 ➀ 62 500 / 30 000 105 000 ➁ 57 500 / 32 500 97 500 ➂ Pa [in H O] 2 1200 3 0,8 1,6 2,4 3,2 4,0 1000 800 2 600 1 400 200 0 50 100 150 200 250 300 350 400 CFM 100 200 300 400 500 600 m³/h 68 Guard grilles from p. 238 tin-plated Information DC axial fans DC centrifugal fans max. 360 m3/h DC axial fans Series 7100 N Ø 150 x 38 mm – Material: Housing: Die-cast aluminium – Possible special versions: Impeller: Painted sheet steel (See chapter DC fans - specials) – Direction of air flow: Exhaust over struts - Speed signal – Direction of rotation: Counter-clockwise, seen - Go / No-go alarm on rotor - Alarm with limit speed – Connection: Via single wires AWG 22, - External temperature sensor TR 64 - Internal temperature sensor – Highlights: Housing with grounding lug for - PWM control input screw M4 x 8 (Torx) - Analogue control input – Mass: 620 g - Protection against moisture - Protection against salt fog - Type of protection: IP 54 / IP 68 Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power* Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type 7112 N 7114 N 7114 NH 7118 N Subject to alternations m3/h CFM VDC VDC dB(A) Bel(A) / Watts rpm °C 308 181 12 6...15 53 6,2 12,0 2 850 -25...+72 308 181 24 12...30 53 6,2 360 212 24 12...26,5 58 6,7 12,0 2 850 -25...+72 19,0 3 350 -25...+72 308 181 48 24...60 53 6,2 12,0 2 850 -25...+72 * Input power at free air flow, these values can be significantly higher in the operating point. Hours Hours 80 000 / 37 500 135 000 ➀ 80 000 / 37 500 135 000 ➀ 75 000 / 35 000 127 500 ➁ 80 000 / 37 500 135 000 ➀ DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Guard grilles from p. 238 Strand fastened using cable tie; cable tie protrudes 1 mm. tin-plated 69 Representatives max. 360 m3/h DC axial fans Series 7200 N Ø 150 x 55 mm – Material: Housing: Die-cast aluminium – Possible special versions: Impeller: GRP1) (PA) (See chapter DC fans - specials) – Direction of air flow: Exhaust over struts - Speed signal – Direction of rotation: Counter-clockwise, seen - Go / No-go alarm on rotor - Alarm with limit speed – Connection: Via single wires AWG 22, - External temperature sensor TR 64 - Internal temperature sensor – Highlights: Housing with grounding lug for - PWM control input screw M4 x 8 (Torx) - Analogue control input – Mass: 725 g - Protection against moisture - Protection against salt fog - Type of protection: IP 54 / IP 68 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power* Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type 7212 N 7214 N 7218 N Subject to alternations m3/h CFM VDC VDC dB(A) Bel(A) / Watts rpm °C 360 212 12 6...15 53 6,2 12,0 3 050 -25...+72 360 212 24 12...30 53 6,2 12,0 3 050 -25...+72 360 212 48 24...60 53 6,2 12,0 3 050 -25...+72 * Input power at free air flow, these values can be significantly higher in the operating point. Hours Hours 80 000 / 37 500 135 000 ➀ 80 000 / 37 500 135 000 ➀ 80 000 / 37 500 135 000 ➀ Pa [in H O] 2 0, 4 1 125 100 75 50 25 0, 3 0, 2 0, 1 0 40 80 120 160 200 CFM 100 200 300 m³/h 70 Guard grilles from p. 238 tin-plated Information DC axial fans DC centrifugal fans max. 350 m3/h DC axial fans Series 6100 N 172 x 160 x 52 mm – Material: Housing: GRP1) (PBT) Impeller: GRP1) (PA) – Direction of air flow: Exhaust over struts – Direction of rotation: Counter-clockwise, seen on rotor – Connection: Via single wires AWG 22, TR 64 – Highlights: Light and compact plastic housing – Mass: 610 g – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Protection against moisture - Type of protection: IP 54 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power* Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type 6112 NM 6114 NM Subject to alternations m3/h CFM VDC VDC dB(A) Bel(A) / Watts rpm °C 350 206 12 8...15 49 5,9 11 2 850 -20...+70 350 206 24 12...32 49 5,9 11 2 850 -20...+70 * Input power at free air flow, these values can be significantly higher in the operating point. Hours Hours 80 000 / 40 000 135 000 ➀ 80 000 / 40 000 135 000 ➀ DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Pa [in H2O] Accessories 0,1 0,2 0,3 0,4 0,5 150 1 125 100 75 50 25 0 40 80 120 160 200 CFM 100 200 300 m³/h Guard grilles from p. 238 tin-plated 71 8,2 deep Representatives max. 545 m3/h DC axial fans Series 6300 Ø 172 x 51 mm – Material: Housing: Die-cast aluminium – Possible special versions: Impeller: GRP1) (PA) (See chapter DC fans - specials) – Direction of air flow: Exhaust over struts - Speed signal – Direction of rotation: Counter-clockwise, seen - Go / No-go alarm on rotor - Alarm with limit speed – Connection: Via single wires AWG 22, - External temperature sensor TR 64 - Internal temperature sensor – Highlights: Housing with grounding lug for - PWM control input screw M4 x 8 (Torx) - Analogue control input – Mass: 910 g - Protection against moisture - Protection against salt fog - Type of protection: IP 54 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power* Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type 6314/2 MP 6314/2 NP 6314/2 HP 6318/2 HP Subject to alternations m3/h CFM VDC VDC dB(A) Bel(A) / Watts rpm °C 395 232 24 16...30 51 6,0 470 276 24 16...30 56 6,5 545 320 24 16...30 58 6,9 545 320 48 36...72 58 6,9 14 3 700 -20...+75 23 4 400 -20...+70 31 5 000 -20...+65 32 5 000 -20...+65 Speed control range from 700 rpm up to maximum nominal speed. Stationary at 0 % PWM, maximum speed at sensor break. * Input power at free air flow, these values can be significantly higher in the operating point. Hours Hours 82 500 / 32 500 140 000 ➀ 80 000 / 40 000 135 000 ➁ 77 500 / 42 500 130 000 ➂ 77 500 / 42 500 130 000 ➂ [Pa] 0,25 0,5 0,75 1 1,25 1,5 1,75 2 [in H O] 2 500 3 400 2 300 200 1 100 0 50 100 150 200 250 300 [CFM] 100 200 300 400 500 [m3/h] 72 Guard grilles from p. 238 tin-plated 7,6 deep Information DC axial fans DC centrifugal fans max. 930 m3/h DC axial fans Series 6300 TD Ø 172 x 51 mm – Material: Housing: Die-cast aluminium – Possible special versions: Impeller: GRP1) (PA) (See chapter DC fans - specials) – Direction of air flow: Exhaust over struts - Speed signal – Direction of rotation: Counter-clockwise, seen - Go / No-go alarm on rotor - Alarm with limit speed – Connection: Via single wires AWG 18, 20 - External temperature sensor or AWG 22, TR 64, speed signal - Internal temperature sensor and control input AWG 22 - PWM control input – Highlights: 3-phase fan drive with very - Analogue control input smooth running and high - Multi-option control input efficiency. Housing with groun- - Protection against moisture ding lug for screw M4 x 8 (Torx) - Protection against salt fog – Mass: 910 g - Type of protection: IP 54 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power* Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type 6312/2 TDHP NEW 6314/2 TDHP-298 6314/2 TDHP 6314/2 TDHHP NEW 6314/2 TDH4P NEW 6318/2 TDHP-299 6318/2 TDHP 6318/2 TDHHP 6318/2 TDH4P Subject to alternations m3/h CFM VDC VDC dB(A) Bel(A) / 600 353 12 8...16 60 7,3 600 353 24 16...30 60 7,3 600 353 24 16...36 60 7,3 710 418 24 16...36 69 7,9 930 545 24 16...36 75 8,4 600 353 48 36...60 60 7,3 600 353 48 36...72 60 7,3 710 418 48 36...72 69 7,9 930 545 48 36...72 75 8,4 Watts 40 42 40 67 150 42 40 67 150 rpm 5 500 5 500 5 500 7 000 9 200 5 500 5 500 7 000 9 200 °C -20...+70 -20...+65 -20...+75 -20...+75 -20...+75 -20...+65 -20...+75 -20...+75 -20...+75 Speed control range from 1000 rpm up to maximum nominal speed. Stationary at 0 % PWM, maximum speed at sensor break. * Input power at free air flow, these values can be significantly higher in the operating point. Hours Hours 75 000 / 37 500 127 500 ➁ 75 000 / 42 500 127 500 ➀ 75 000 / 30 000 127 500 ➁ 62 500 / 25 000 105 000 ➂ 52 500 / 20 000 87 500 ➄ 75 000 / 42 500 127 500 ➀ 75 000 / 30 000 127 500 ➁ 62 500 / 25 000 105 000 ➂ 52 500 / 20 000 87 500 ➃ DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Representatives * Input power - in operation Fan type 6318/2 TDHHP 6318/2 TDH4P optimum operating range (W) 115 270 tin-plated 7,6 deep Guard grilles from p. 238 73 max. 930 m3/h DC axial fans Series 6300 TD 172 x 160 x 51 mm – Material: Housing: Die-cast aluminium – Possible special versions: Impeller: GRP1) (PA) (See chapter DC fans - specials) – Direction of air flow: Exhaust over struts - Speed signal – Direction of rotation: Counter-clockwise, seen - Go / No-go alarm on rotor - Alarm with limit speed – Connection: Via single wires AWG 18, 20 - External temperature sensor or AWG 22, TR 64, speed signal - Internal temperature sensor and control input AWG 22 - PWM control input – Highlights: 3-phase fan drive with very - Analogue control input smooth running and high - Multi-option control input efficiency. Housing with groun- - Protection against moisture ding lug for screw M4 x 8 (Torx) - Protection against salt fog – Mass: 910 g - Type of protection: IP 54 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power* Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type 6314/2 TDHHP-015 6318/2 TDH4P-007 Subject to alternations m3/h CFM VDC VDC dB(A) Bel(A) / Watts rpm °C 710 418 24 16...36 69 7,9 67 7 000 -20...+75 930 546 48 36...72 75 8,4 150 9 200 -20...+75 Speed control range from 1000 rpm up to maximum nominal speed. Stationary at 0 % PWM, maximum speed at sensor break. * Input power at free air flow, these values can be significantly higher in the operating point. Hours Hours 62 500 / 25 000 105 000 ➀ 52 500 / 20 000 87 500 ➁ Pa [in H O] 2 3, 2 2, 4 2 1000 800 1 600 400 200 1, 6 0, 8 0 100 200 300 400 500 600 CFM 200 400 600 800 1000 m³/h 74 Guard grilles from p. 238 tin-plated 7,6 deep Information DC axial fans DC centrifugal fans DC fans - specials max. 1100 m3/h DC diagonal fans Series DV 6300 Ø 172 x 51 mm – Material: Housing: Die-cast aluminium – Possible special versions: Impeller: GRP1) (PA) (See chapter DC fans - specials) – Direction of air flow: Exhaust over struts - Speed signal – Direction of rotation: Counter-clockwise, seen - Go / No-go alarm on rotor - Alarm with limit speed – Connection: (+) and GND: AWG 18, UL 1007, - External temperature sensor TR 64, speed signal and control - Internal temperature sensor input AWG 22, UL 1007, TR 64 - PWM control input – Highlights: 3-phase fan drive with very - Analogue control input smooth running and high - Multi-option control input efficiency. Housing with groun- - Protection against moisture ding lug for screw M4 x 8 (Torx) - Protection against salt fog – Mass: 1050 g - Type of protection: IP 54 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type m3/h CFM VDC VDC dB(A) Bel(A) / Watts rpm °C NEW DV 6318/2 TDHHP* NEW DV 6318/2 TDH3P* NEW DV 6318/2 TDH4P NEW DV 6318/2 TDH5P** * provisional ** Rotor protrusion a = 3 mm Subject to alternations 630 371 48 36…72 68 7,6 770 453 48 36…72 73 8,0 1050 617 48 36…72 77 8,7 1100 647 48 36…72 79 8,9 75 4000 -20…+65 135 4900 -20…+65 300 6500 -20…+65 360 6800 -20…+65 Speed control range from 1000 rpm up to maximum nominal speed. Stationary at 0 % PWM, maximum speed at sensor break. The fans have a speed increase of up to 30%, thus producing a more even characteristic curve. Hours Hours 70 000 / 40 000 117 500 ➀ 60 000 / 32 500 102 500 ➁ 50 000 / 27 500 85 000 ➂ 40 000 / 22 500 67 500 ➃ n rpm   4000   3835   3815   3930   4240   4900   4690   4670   4870   5190 Ped LwA L10 (40 °C) L10 (65 °C) L10IPC (40 °C) W dB(A) 65,5 79 64,5 78 64,5 76 65 76 66 79 120 83 119 82 119 80 120 81 121 85 70 000 72 500 75 000 77 500 77 500 60 000 67 500 72 500 75 000 75 000 40 000 40 000 42 500 42 500 42 500 32 500 37 500 40 000 42 500 42 500 117 500 122 500 127 500 130 000 130 000 102 500 115 000 122 500 127 500 127 500 n rpm   6500   6230   6200   6450   6900   6950   6720   6630   6850   7300 Ped LwA L10 (40 °C) L10 (65 °C) L10IPC (40 °C) W dB(A) 280 90 275 89 280 88 281 88 283 92,5 345 92 345 91 345 89,5 345 89 345 94 50 000 62 500 70 000 72 500 72 500 40 000 57 500 62 500 67 500 72 500 27 500 35 000 40 000 40 000 40 000 22 500 32 500 35 000 37 500 40 000 85 000 105 000 117 500 122 500 122 500 67 500 97 500 105 000 115 000 122 500 tin-plated ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Representatives Guard grilles from p. 238 75 max. 480 m3/h DC axial fans Series 6400 172 x 150 x 51 mm – Material: Housing: Die-cast aluminium – Possible special versions: Impeller: GRP1) (PA) (See chapter DC fans - specials) – Direction of air flow: Exhaust over struts - Speed signal – Direction of rotation: Counter-clockwise, seen - Go / No-go alarm on rotor - Alarm with limit speed – Connection: On flat plugs 3 x 0.5 mm - External temperature sensor – Highlights: Housing with grounding lug for - Internal temperature sensor screw M4 x 8 (Torx) - PWM control input – Mass: 760 g - Analogue control input - Protection against moisture - Protection against salt fog - Type of protection: IP 54 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power*** Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type 6412 M 6424 M 6424 6424 H 6448 6448 H* Subject to alternations m3/h CFM VDC VDC dB(A) Bel(A) / 350 206 12 8...15 52 6,0 350 206 24 12...32 52 6,0 410 241 24 12...28 57 6,4 480 283 24 12...28 63 7,1 410 241 48 28...60 57 6,4 480 283 48 28...60 63 7,1 Watts 12 12 17 26 17 26 rpm 2 850 2 850 3 400 4 000 3 400 4 000 °C Hours Hours -20...+72 80 000 / 37 500 135 000 ➀ -20...+72 80 000 / 37 500 135 000 ➀ -20...+72 75 000 / 35 000 127 500 ➁ -20...+55** 70 000 / 50 000 117 500 ➂ -20...+72 75 000 / 35 000 127 500 ➁ -20...+55** 70 000 / 50 000 117 500 ➂ * Strand 310 mm. ** 72 °C versions on request *** Input power at free air flow, these values can be significantly higher in the operating point. Pa [in H2O] 3 175 0,1 0,2 0,3 0,4 0,5 0,6 150 2 125 100 1 75 50 25 0 50 100 150 200 250 CFM 100 200 300 400 m³/h 76 Guard grilles from p. 238 Connection cables from p. 251 7,5 deep Information DC axial fans DC centrifugal fans max. 900 m3/h DC axial fans Series 6400 TD TURBOFAN 172 x 150 x 51 mm – Material: Housing: Die-cast aluminium – Possible special versions: Impeller: GRP1) (PA) (See chapter DC fans - specials) – Direction of air flow: Exhaust over struts - Speed signal – Direction of rotation: Counter-clockwise, seen - Go / No-go alarm on rotor - Alarm with limit speed – Connection: Via single wires AWG 18, 20 - External temperature sensor or AWG 22, TR 64, speed signal - Internal temperature sensor and control input AWG 22 - PWM control input – Highlights: 3-phase fan drive with very - Analogue control input smooth running and high - Protection against moisture efficiency. Housing with groun- - Protection against salt fog ding lug for screw M4 x 8 (Torx) - Type of protection: IP 54 – Mass: 760 g - Reversible direction of rotation 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power** Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type min 6424 TD... max min 6448 TD... max min 6448 TDHH... max Subject to alternations m3/h CFM VDC VDC dB(A) Bel(A) / Watts 90 53 18 — 2 24 16...28 600 353 65 7,4 50 90 53 18 — 2 48 40...55* 600 353 65 7,4 50 90 53 18 — 2 48 36...72 900 530 78 8,6 163 * Variants with an extended voltage range available to deliver on request. rpm 800 5 100 800 5 100 800 7500 °C -20...+60 -20...+60 -20...+60 Hours Hours ➀ 70 000 / 45 000 117 500 ➁ ➀ 70 000 / 45 000 117 500 ➁ ➀ 70 000 / 45 000 117 500 ➂ Models 6424 TD..., 6448 TD... and 6448 TDHH... are available in customer-specific, custom-developed variants only. The data specified here is technically feasible benchmark values. The fans can be specially adapted to your application with signal outputs and control inputs. For details of the technical possibilities, refer to the chapters on the sensor signal, alarm signal and control inputs beginning on page 161. ** Input power at free air flow, these values can be significantly higher in the operating point. DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Guard grilles from p. 238 tin-plated (7,5 deep) 77 Representatives max. 530 m3/h DC diagonal fans Series DV 6400 172 x 160 x 51 mm – Material: Housing: Die-cast aluminium – Possible special versions: Impeller: GRP1) (PA) (See chapter DC fans - specials) – Direction of air flow: Exhaust over struts - Speed signal – Direction of rotation: Counter-clockwise, seen - Go / No-go alarm on rotor - Alarm with limit speed – Connection: Via single wires AWG 22, - External temperature sensor TR 64 - Internal temperature sensor – Highlights: Housing with grounding lug for - PWM control input screw M4 x 8 (Torx) - Analogue control input – Mass: 820 g - Protection against moisture - Protection against salt fog - Type of protection: IP 54 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type DV 6424 DV 6448 Subject to alternations m3/h CFM VDC VDC dB(A) Bel(A) / 530 312 24 16...28 65 7,3 530 312 48 28...60 65 7,3 Watts 40 40 rpm 4 300 4 300 °C -20...+75 -20...+75 Hours Hours 90 000 / 35 000 152 500 ➀ 90 000 / 35 000 152 500 ➀ Pa [in H2O] 0,2 0,4 0,6 0,8 1,0 1,2 1 350 300 250 200 150 100 50 0 60 120 180 240 300 CFM 100 200 300 400 500 m³/h 78 Guard grilles from p. 238 tin-plated (7,5 deep) Information DC axial fans DC centrifugal fans max. 680 m3/h DC diagonal fans Series DV 6400 TD TURBOFAN 172 x 160 x 51 mm – Material: Housing: Die-cast aluminium – Possible special versions: Impeller: GRP1) (PA) (See chapter DC fans - specials) – Direction of air flow: Exhaust over struts - Speed signal – Direction of rotation: Counter-clockwise, seen - Go / No-go alarm on rotor - Alarm with limit speed – Connection: Via single wires AWG 22, - External temperature sensor TR 64 - Internal temperature sensor – Highlights: 3-phase fan drive with very - PWM control input smooth running and high - Analogue control input efficiency. Housing with groun- - Protection against moisture ding lug for screw M4 x 8 (Torx) - Protection against salt fog – Mass: 820 g - Type of protection: IP 54 1) Fibreglass-reinforced plastic - Reversible direction of rotation Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power* Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type DV 6424 TD min DV 6424 TD... max min DV 6448 TD... max Subject to alternations m3/h CFM VDC VDC dB(A) Bel(A) / 680 400 24 16...28 71 7,9 100 59 29 — 24 16...28 680 400 71 7,9 100 59 29 — 48 40...55 680 400 71 7,9 Watts 91 2 91 2 86 rpm 5 500 800 5 500 800 5 500 °C -20...+60 -20...+60 -20...+60 Hours Hours 65 000 / 40 000 110 000 ➁ ➀ 65 000 / 40 000 110 000 ➁ ➀ 65 000 / 40 000 110 000 ➁ Models DV 6424 TD... and DV 6448 TD... are available in customer-specific, custom-developed variants only. The data specified here is technically feasible benchmark values. The fans can be specially adapted to your application with signal outputs and control inputs. For details of the technical possibilities, refer to the chapters on the sensor signal, alarm signal and control inputs beginning on page 161. * Input power at free air flow, these values can be significantly higher in the operating point. DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Guard grilles from p. 238 tin-plated (7,5 deep) 79 Representatives max. 1220 m3/h DC axial fans Series 2200 FTD 220 x 200 x 51 mm – Material: Housing: Die-cast aluminium – Possible special versions: Impeller: GRP1) (PA) (See chapter DC fans - specials) – Direction of air flow: Exhaust over struts - Speed signal – Direction of rotation: Counter-clockwise, seen - Go / No-go alarm on rotor - Alarm with limit speed – Connection: Via single wires AWG 18, 20 - External temperature sensor or AWG 22, TR 64, speed signal - Internal temperature sensor and control input AWG 22 - PWM control input – Highlights: 3-phase fan drive with very - Analogue control input smooth running and high - Multi-option control input efficiency. Housing with groun- - Protection against moisture ding lug for screw M4 x 8 (Torx) - Protection against salt fog – Mass: 1000 g - Type of protection: IP 54 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power* Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type 2214 F/2 TDHO 2214 F/2 TDHHO 2218 F/2 TDHO 2218 F/2 TDHHO 2218 F/2 TDH4P Subject to alternations m3/h CFM VDC VDC dB(A) Bel(A) / 790 465 24 16...30 62 7,1 940 553 24 16...36 66 7,4 790 465 48 36...57 62 7,1 940 553 48 36...72 66 7,4 1220 718 48 36...72 72 8,2 Watts rpm °C 35 4250 -25...+75 48 5000 -25...+70 35 4250 -25...+75 48 5000 -25...+70 103 6500 -20...+65 Speed control range from 1000 rpm up to maximum nominal speed. Stationary at 0 % PWM / 0 V, Type O: stationary at sensor break; Type P: maximum speed at sensor break. * Input power at free air flow, these values can be significantly higher in the operating point. Hours Hours 90 000 / 42 500 152 500 ➀ 85 000 / 42 500 142 500 ➁ 90 000 / 42 500 152 500 ➀ 85 000 / 42 500 142 500 ➁ 70 000 / 40 000 117 500 ➂ [in H O] 2 Pa 0,5 1,0 1,5 2,0 2,5 3,0 3,5 3 800 2 600 400 1 200 0 0 100 200 300 400 500 600 CFM 200 400 600 800 1000 m³/h 80 Guard grilles from p. 238 tin-plated 7,6 deep Information DC axial fans DC centrifugal fans max. 1000 m3/h DC axial fans Series 2200 TD 225 x 225 x 80 mm – Material: Wall ring: Die-cast aluminium Impeller: GRP1) (PA) – Direction of air flow: Exhaust over struts – Direction of rotation: Counter-clockwise, seen on rotor – Connection: With terminal strip – Highlights: 3-phase fan drive with very smooth running Fully integrated electronic commutation – Mass: 2,1 kg – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Multi-option control input - Protection against moisture - Type of protection: IP 54 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power* Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type 2214/2 TDO 2218/2 TDO Subject to alternations m3/h CFM VDC VDC dB(A) Bel(A) / Watts rpm °C 1000 588 24 16...30 59 6,8 1000 588 48 36...57 59 6,8 50 3 000 -20...+60 50 3 000 -20...+60 * Input power at free air flow, these values can be significantly higher in the operating point. Hours Hours 80 000 / 50 000 135 000 ➀ 80 000 / 50 000 135 000 ➀ DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Representatives Guard grilles from p. 238 81 max. 1245 m3/h DC diagonal module 225 x 225 x 80 mm – Material: Housing: Fibreglass-reinforced plastic (PA6) Impeller: Fibreglass-reinforced plastic (PA) – Direction of air flow: Exhaust over struts – Direction of rotation: Clockwise, seen on rotor – Connection: Via connection line AWG 20, 4x brass lead tips crimped – Mass: 1,7 kg – Operation mode: Continuous operation (S1) Curve Nominal voltage Voltage range Air flow Speed / rpm Input power Current draw Sound power level Perm. amb. temp. Technical features and electrical connections Nominal data Type K1G 200-AD65-04 K1G 200-AD31-02 K1G 200-AD49-04 K1G 200-AD37-02 Subject to alternations Motor M1G 074-BF ➀ M1G 074-BF ➁ M1G 074-BF ➂ M1G 074-BF ➃ VDC VDC m3/h rpm W 24 16...28 1020 24 16...28 1045 48 36...57 1095 48 36...57 1245 3 400 95 3 520 107 3 650 120 4 140 183 A dB(A) °C 4,7 76 -25...+60 5,4 77 -25...+70 3,4 77 -25...+60 5,6 81 -25...+70 p. 258 / J5) p. 258 / J5) p. 258 / J5) p. 258 / J5) n Ped I LwA rpm W A dB(A)   3400 95 4,70 76   3410 116 5,61 74   3410 119 5,75 74   3410 117 5,62 76   3520 107 5,30 77   3520 127 6,24 75   3520 129 6,31 76   3520 126 6,18 76   3650 120 3,40 77   3650 141 3,90 75   3650 145 3,99 76   3650 141 3,88 78   4140 183 5,60 81   4090 212 6,46 79   4060 213 6,52 79   4110 211 6,43 80 Air performance measured as per: ISO 5801, Installation category A, without protection against accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted! For detailed information see http://www.ebmpapst.com/general conditions Cable assignment: Red = UN Yellow = 0-10 VDC White = Speed monitoring output Blue = GND 288 276+- 0,5 82 Guard grilles from p. 238 Electrical connections from p. 258 6 80 +1 Information DC axial fans DC centrifugal fans DC fans - specials max. 905 m3/h DC diagonal module 225 x 225 x 89 mm – Material: Housing: Fibreglass-reinforced plastic (PA6) Impeller: Fibreglass-reinforced plastic (PA) – Direction of air flow: Exhaust over struts – Direction of rotation: Clockwise, seen on rotor – Connection: Via connection line AWG 16, 4x brass lead tips crimped – Mass: 2,2 kg – Operation mode: Continuous operation (S1) Curve Nominal voltage Voltage range Air flow Speed / rpm Input power Current draw Sound power level Perm. amb. temp. Technical features and electrical connections Nominal data Type K3G 200-BD46-04 K3G 200-BD44-02 K3G 200-BD64-04 K3G 200-BDA8-02 Subject to alternations Motor M3G 074-CF ➀ M3G 074-CF ➁ M3G 074-CF ➂ M3G 074-CF ➃ VDC VDC m3/h rpm W 24 16...28 725 4120 170 24 16...28 805 4830 275 48 36...57 900 4890 280 48 36...57 905 5470 400 A dB(A) °C 7,0 80 -25...+60 11,5 84 -25...+60 5,9 85 -25...+60 8,4 88 -25...+60 p. 258 / J5) p. 258 / J5) p. 258 / J5) p. 258 / J5) n Ped I LwA rpm W A dB(A)   4120 170 7,0* 80   4025 180 7,52* 77   4005 187 7,80* 76   4045 187 7,78* 78   4830 275 11,5* 84   4720 294 12,24* 81   4685 299 12,48* 80   4715 295 12,30* 83   4890 280 5,9* 85   4795 300 6,27* 81   4755 307 6,41* 80   4780 304 6,35* 82   5470 400 8,4* 88   5365 426 8,89* 85   5310 438 9,17* 83   5355 431 9,01* 87 Air performance measured as per: ISO 5801, Installation category A, without protection against accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted! For detailed information see http://www.ebmpapst.com/general conditions * current measured at nominal voltage Cable assignment: Red = UN Yellow = 0-10 VDC White = Speed monitoring output Blue = GND ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans 288 276+- 0,5 Accessories Representatives Guard grilles from p. 238 Electrical connections from p. 258 6 89 +1 83 max. 2070 m3/h DC axial fans Ø 250 mm – Material: – Number of blades: – Direction of air flow: – Direction of rotation: – Insulation class: – Mounting position: – Condensate discharges: – Operation mode: – Bearings: Wall ring: Die-cast aluminium Blades: Plastic (PP) Rotor: Thick layer passivated 7 "V" Counter-clockwise, seen on rotor "B" Any On rotor side Continuous operation (S1) Maintenance-free ball bearings Curve Nominal voltage Voltage range Air flow Speed / rpm Input power Current draw Max. back-pressure Perm. amb. temp. Technical features and electrical connections Nominal data Type W1G250-HJ87 -02 W1G250-HJ63 -02 Subject to alternations Motor M1G 074-BF A M1G 074-BF B VDC VDC m3/h rpm W A Pa °C 24 16-28 2070 3090 120 6,80 150 -25...+60 48 36-57 2070 3090 120 3,40 150 -25...+60 p. 254 / E) p. 254 / E) in H2O Curve: 160 140 120 100 80 Pa 0,4 0,5 0,6 B A 4 3 n Ped rpm W A 1 3090 120 A 2 2950 124 A 3 2820 127 A 4 2730 130 B 1 3090 120 B 2 2950 124 B 3 2820 127 B 4 2730 130 I LWA A dB(A) 6,80 74 7,10 73 7,43 73 7,80 78 3,40 74 3,55 73 3,74 73 3,90 78 0,3 0,2 60 2 40 0,1 20 pfs 1 0 200 400 600 800 1000 1200 cfm qV 400 800 1200 1600 2000 m3/h Air performance measured as per: ISO 5801, Installation category A, without protection against accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted! For detailed information see http://www.ebmpapst.com/general conditions 84 Information DC axial fans – Technical features: – EMC: – Electrical connection: – Protection class: – Product conforming to standards: See electrical connections p. 254 Interference emission acc. to EN 55022 (Class B) Interference immunity acc. to EN 61000-6-2 (industrial environment) Via terminal strip I EN 60950-1 DC centrifugal fans DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans 3.7 280 Ø 295 Ø 320 Guard grilles from p. 238 Electrical connections from p. 254 PE (1) (2) - + Ø5.4+0.2 (8x) (1) Control input (2) Speed output 7 7 80±0.3 "V" 85 Accessories Representatives max. 2345 m3/h DC axial fans – HyBlade® Ø 300 mm – Material: – Number of blades: – Direction of air flow: – Direction of rotation: – Type of protection: – Insulation class: – Mounting position: – Condensate discharges: – Operation mode: – Bearings: Guard grille: Steel, phosphated and coated in black plastic Wall ring: Sheet steel, pre-galvanised and coated in black plastic Blades: Plastic (PP) Rotor: Coated in black 5 "V" Counter-clockwise, seen on rotor IP 42 "B" Any None Continuous operation (S1) Maintenance-free ball bearings Curve Nominal voltage Voltage range Air flow Speed / rpm Input power Current draw Max. back-pressure Perm. amb. temp. Technical features and electrical connections Nominal data Type *1G 300 *1G 300 Subject to alternations Motor M1G 074-CF A M1G 074-CF B VDC VDC m3/h rpm 24 16-28 2320 1830 48 36-57 2345 1830 W A Pa °C 80 3,80 100 -25..+60 80 1,90 100 -25..+60 p. 258 / J5) p. 258 / J5) in H2O Pa Curve: 110 0,4 100 AB 90 44 80 0,3 70 3 60 3 0,2 50 2 40 30 2 0,1 20 10 pfs 1 0 200 400 600 800 1000 1200 cfm qV 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 m3/h Air performance measured as per: ISO 5801, Installation category A, with ebm-papst inlet nozzle without protection against accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted! For detailed information see http://www.ebmpapst.com/general conditions n Ped rpm W A 1 1810 80 A 2 1730 86 A 3 1690 87 A 4 1635 89 B 1 1870 87 B 2 1805 90 B 3 1765 91 B 4 1695 92 I LWA A dB(A) 3,80 67 4,03 67 4,10 66 4,21 70 2,00 68 2,10 67 2,13 67 2,19 69 86 Information DC axial fans – Technical features: – EMC: – Cable exit: – Product conforming to standards: – Approvals: See electrical connections p. 258 Interference emission acc. to EN 55022 (Class B) Interference immunity acc. to EN 61000-6-2 (industrial environment) lateral EN 60950-1 GOST, CSA C22.2 Nr. 77, UL 1004-1 DC centrifugal fans Direction of air flow Mass without attachments Mass with full round nozzle Mass with guard grille for short nozzle DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans "V" Without attachments "V" kg With full round nozzle "V" kg With guard grille for short nozzle kg "V" A1G 300-AC19 -54 1,8 W1G 300-DC19 -54 3,8 S1G 300-AC19 -54 2,8 "V" A1G 300-AC33 -54 1,8 W1G 300-DC33 -54 3,8 S1G 300-AC33 -54 3,1 A1G 300 Depth of screw max. 6 mm 79±5 57.5±3 M4 (4x) 45° Ø300±1 450+20 31 Ø92 90° 75 Ø58±0.15 "V" 80 11 Ø380 Ø9(6x) 15° 60°(6x) 85±10 6 Connection line PVC AWG 20, 4 x lead tips crimped 25±3 Ø300 ±1 Ø329.6 Ø360 Ø326 Ø397 W1G 300 4.5 57.2 29±5 4.3 S1G 300 Guard grilles from p. 238 Electrical connections from p. 258 87 AC centrifugal fans Accessories Representatives 88 89 Representatives Accessories AC centrifugal fans AC axial fans ACmaxx / GreenTech EC-Compact fans DC fans - specials DC centrifugal fans DC axial fans 136 DC centrifugal fans and blowers 134 DC tangential fans 93 DC centrifugal fans 91 DC centrifugal fan overview DC centrifugal fans Information DC centrifugal fans Technical information Product line Our centrifugal product line includes fans for every application. Whether as free-running impellers with a diameter between 97 mm and 225 mm or as assemblies in a ready-to-install, compact housing with inlet nozzle with an edge length between 51 mm and 270 mm. Of course, all models feature high-efficiency, brushless motor technology. Voltage range Many of our DC fans can be operated on voltages that are up to 50% lower and 25% higher than their nominal voltage (see Voltage range in the technical tables). This enables the air performance to be adapted to the cooling requirements and allows the noise to be reduced, even if the fan does not have a control input. Electronic protection against reverse polarity ebm-papst DC fans have electronically commutated drives with electronic protection against reverse polarity.The electronics are conveniently located in the fan hub. Product life expectancy A distinctive feature of DC fan technology is the convincingly high product life expectancy. Thanks to the excellent efficiency of the brushless drives, the thermal load of the bearings is reduced, thus considerably increasing the life expectancy of the fans. Type of protection DC fans with sleeve and ball bearings are powered by class E insulated motors. All ebm-papst fans conform to the requirements of type of protection IP 20. Fans conforming to IP 54 / IP 68 and special types of protection are also available. Closed-loop speed control and monitoring Closed-loop speed control and function monitoring are becoming increasingly important in many applications. ebm-papst offers many fans in the standard design with a control input and open collector speed signal. S-Force centrifugal – RadiCal The new S-Force centrifugal fans provide peak performance among fans of this type. With air flow capacity of over 1500 m³/h and a pressure build-up of up to 1000 pascals, the highest heat flows are manageable. In addition, the models are extremely efficient due to the multi-pole, electronically commutated drive motors and can be adapted individually to every application thanks to intelligent motor features. Some models use our new, highly efficient RadiCal impellers. 90 Information Page DC axial fans DC centrifugal fans DC fans - specials Centrifugal fans for DC operation Overview of air performance Dimensions Series Air flow mm m3/h 10 105 x 59 x 79 RV 40 18...24 c 51 x 15 RLF 35 9,6 c 76 x 27 RL 48 22...28 97 x 93,5 x 33 RL 65 56...61 c 121 x 37 RL 90 N 40...55 c 127 x 25 RLF 100 64...80 c 135 x 38 RG 90 N 55 c 180 x 40 RG 125 N 60...137 c 220 x 56 RG 160 N 139...209 c 220 x 56 RG 160 NTD 59...444 c 225 x 85 RG 190 TD 630...930 c 270 x 99 RG 220 TD 1090...1280 c 270 x 119 RG 225 TD 1040...1450 Ø 97 x 41 RET 97 TD 220 Ø 104 x 25 REF 100 86...104 Ø 101 x 52 RER 101 162...190 Ø 120 x 54 RER 120 TD 320...390 Ø 120 R1G 120 250 Ø 138 x 35 RER 125 N 110...166 Ø 133 x 91 RER 133 TD 460...565 Ø 165 x 51 RER 160 N 255 Ø 165 x 51 RER 160 NTD 66...354 Ø 175 x 55 REF 175 TD 800 Ø 175 x 69 RER 175 TD 600...980 Ø 190 x 69 RER 190 TD 650...970 Ø 190 R3G 190 880...930 Ø 220 R3G 220 1185...1210 Ø 220 x 71 RER 220 TD 1090...1280 Ø 225 x 99 RER 225 TD 1190...1600 Ø 225 R3G 225 1275...1400 Ø 250 R3G 250 1640...1650 Ø 280 R3G 280 2175...2210 Ø 310 R3G 310 2380...2420 201...413 x 50 x 48 QG 030 75...155 Ø 85 *1G 085 95 Ø 97 *1G 097 95 Ø 108 *1G 108 200 Ø 120 *1G 120 255 Ø 133 *1G 133 225 Ø 140 *1G 140 400...410 Ø 146 *1G 146 465...470 Ø 160 *1G 160 505 Ø 133 D1G 133 700 Ø 133 D1G 133 1020 Ø 146 D1G 146 1000 Ø 160 D1G 160 980 Subject to alternations m3/h 10 20 30 40 50 60 70 80 90 100 20 30 40 50 60 70 80 90 100 200 300 400 500 600 700 800 900 1000 200 300 400 500 600 700 800 900 1000 2000 3000 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 112 113 114 115 116 117 118 120 122 124 125 126 128 130 132 134 136 138 140 142 144 146 148 150 152 154 156 158 2000 3000 ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Representatives 91 Centrifugal fans for DC operation Overview of technically feasible designs Dimensions VDE, UL, CSA IIISSAPEPSAHGinlPPMpxatanounatluWeteglrta/>>elrteemeirfMiocnm==d-NnodgaciIIosolagstlluwioPP-pityetetgtnpgieet56rhenpoovrcor48lamenotoilmalopletnbpictmeaceiereonrrttciraonaptrloitatmisutriontunpuornnglerepsiee/unsdbtspealelunntsbsoeorrarings Centrifugal fans Series mm OPTIONAL p. RV 40 105 x 59 x 79 • • – – – – – – – • – – – 93 RLF 35 51 x 51 x 15 ja • – – – – • – – • – – – 94 RL 48 76 x 76 x 27 ja • • • • • • • – • – – – 95 RL 65 97 x 93,5 x 33 ja • • • • • • • – • – – – 96 RL 90 N 121 x 121 x 37 ja / • • • • • • • – • • • • 97 RLF 100 127 x 127 x 25 ja • • • • • • • – • • – – 98 RG 90 N 135 x 135 x 38 ja / • • • • • • • – • • • • 99 RG 125 N 180 x 180 x 40 ja • • • • • • • – • • • • 100 RG 160 N 220 x 220 x 56 ja • • • • • • • – • • – • 101 RG 160 NTD 220 x 220 x 56 ja • • • • • • • – • • – • 102 RG 190 TD 225 x 225 x 85 ja • • • • • • • • • • – • 103 RG 220 TD 270 x 270 x 99 ja • • • • • • • – • • – • 104 RG 225 TD 270 x 270 x 132 ja • • • • • • • – • • – • 105 RET 97 TD Ø 97 x 41 ja • • • • • • • – • – – – 106 REF 100 Ø 100 x 25 ja • • • • • • • – • • – – 107 RER 101 Ø 101 x 52 ja • • • • • • • – • – – – 108 RER 120 TD Ø 120 x 54 ja • • • • • • • – • – – – 109 RER 125 N Ø 138 x 35 ja • • • • • • • – • • • • 112 RER 133 TD Ø 133 x 91 ja • • • • • • • • • • – • 113 RER 160 N Ø 165 x 51 ja • • • • • • • – • • – • 114 RER 160 NTD Ø 165 x 51 ja • • • • • • • – • • – – 115 REF 175 TD Ø 175 x 55 ja • • • • • • • • • • – – 116 RER 175 TD Ø 175 x 69 ja • • • • • • • • • • – • 117 RER 190 TD Ø 190 x 69 ja • • • • • • • • • • – • 118 RER 220 TD Ø 220 x 71 ja • • • • • • • • • • – • 124 RER 225 TD Ø 225 x 99 ja • • • • • • • • • • – • 125 QG 030 201...413 x 50 x 48 ja / • – – – – – – – • – – – 134 Subject to alternations * approvalsapplied for – not yet available • available Sleeve bearings Ball bearings Please note that these special versions are not possible for all voltages and speeds, and not in all combinations. The special versions are designed for specific customers and projects. As a rule they are not available off the shelf and are tied to minimum volumes. Please consult your customer support representative about the feasibility of your special variant. Optional special versions (see page 12) On the catalogue pages and in the overview on page 12, we provide information about the special designs that are technically feasible in the fan series. Please note that these special versions are not possible for all voltages and speeds, and not in all combinations. The special versions are designed for specific customers and projects and are not available off the shelf usually. 92 Information DC axial fans DC centrifugal fans 24 max. m3/h DC centrifugal fans Series RV 40 105 x 59 x 79 mm – Material: Scroll housing: GRP1) Impeller: GRP1) – Direction of air flow: Axial: Intake Centrifugal: Exhaust – Connection: Via single wires AWG 26, TR 64 – Highlights: Forwards-curved impeller – Mass: 100 g – Possible special versions: (See chapter DC fans - specials) - Speed signal - Protection against moisture 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Voltage range Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type RV 40-18/12 L RV 40-18/12 H Subject to alternations m3/h CFM 18 10,6 24 14,1 VDC VDC Bel(A) 12 9...16 4,0 12 9...16 5,0 / Watts rpm °C Hours Hours 2,0 3 900 -20...+70 70 000 / 35 000 117 500 ➀ 4,5 4 800 -20...+70 50 000 / 25 000 85 000 ➁ DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories 45,78 Pa [in H2O] 2 125 0, 4 100 0, 3 75 0, 2 50 1 0, 1 25 0 3 6 9 12 15 CFM 5 10 15 20 25 m³/h Ø 46,5 Ø 30 18 10,5 18,35 36,35 12 58,85 Intake opening Ø 40 60,4 Ø 31 2,3 4,2 (2x) 27 2,51 44,9 32,4 93 42,04 Representatives max. 9,6 m3/h DC centrifugal fans Series RLF 35 51 x 51 x 15 mm – Material: Scroll housing: GRP1) Impeller: GRP1) – Direction of air flow: Axial: Intake Centrifugal: Exhaust – Connection: Via single wires AWG 26, TR 64 – Highlights: Forwards-curved impeller – Mass: 40 g – Possible special versions: (See chapter DC fans - specials) - Speed signal - PWM control input - Protection against moisture 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Voltage range Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type RLF 35-8/12 N RLF 35-8/14 N Subject to alternations m3/h CFM 9,6 5,7 9,6 5,7 VDC VDC Bel(A) 12 8...13,2 5,5 24 14...28 5,5 / Watts rpm °C Hours Hours 3,5 6 700 -20...+70 60 000 / 30 000 102 500 ➀ 4,3 6 700 -20...+70 60 000 / 30 000 102 500 ➀ Pa [in H2O] 175 1 0,1 0,2 0,3 0,4 0,5 0,6 150 125 100 75 50 25 0 1 2 3 4 5 6 7 CFM 2 4 6 8 10 m³/h 94 tin-plated Information DC axial fans DC centrifugal fans 28 max. m3/h DC centrifugal fans Series RL 48 76 x 76 x 27 mm – Material: Scroll housing: GRP1) Impeller: GRP1) – Direction of air flow: Axial: Intake Centrifugal: Exhaust – Connection: Via single wires AWG 26, TR 64 – Highlights: Forwards-curved impeller – Mass: 75 g – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Protection against moisture 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Voltage range Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type RL 48-19/12 ML RL 48-19/12 RL 48-19/14 ML RL 48-19/14 Subject to alternations m3/h CFM VDC VDC Bel(A) 22 12,9 28 16,5 12 8...15 5,3 12 8...13,5 5,7 22 12,9 28 16,5 24 18...28 5,3 24 18...26,4 5,7 / Watts rpm °C Hours Hours 5,0 3 500 -20...+70 70 000 / 35 000 117 500 ➀ 4,6 4 400 -20...+70 60 000 / 30 000 102 500 ➁ 5,0 3 500 -20...+70 70 000 / 35 000 117 500 ➀ 4,4 4 400 -20...+70 60 000 / 30 000 102 500 ➁ DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Pa [in H2O] 0, 4 2 125 100 1 75 50 25 0, 3 0, 2 0,1 0 3 6 9 12 15 CFM 5 10 15 20 25 m³/h tin-plated 95 Representatives 61 max. m3/h DC centrifugal fans Series RL 65 97 x 93,5 x 33 mm – Material: Scroll housing: GRP1) Impeller: GRP1) – Direction of air flow: Axial: Intake Centrifugal: Exhaust – Connection: Via single wires AWG 26, TR 64 – Highlights: Forwards-curved impeller – Mass: 170 g – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Protection against moisture 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Voltage range Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type RL 65-21/12 RL 65-21/12 H RL 65-21/14 RL 65-21/14 H Subject to alternations m3/h CFM 56 33 61 36 56 33 61 36 VDC VDC Bel(A) 12 6,8...13,8 6,6 12 6,8...13,2 6,8 24 12...26,4 6,6 24 12...26,4 6,8 / Watts rpm °C Hours Hours 15,0 4 500 -20...+70 60 000 / 30 000 102 500 ➀ 19,2 4 900 -20...+55 55 000 / 40 000 92 500 ➁ 14,0 4 500 -20...+70 60 000 / 30 000 102 500 ➀ 18,0 4 900 -20...+60 55 000 / 35 000 92 500 ➁ Snaapp--iinn ffinss ffoorr eassyy lastcshembly [in H O] 2 Pa 400 1, 6 2 1 300 1, 2 0, 8 200 100 0, 4 0 10 20 30 CFM 10 20 30 40 50 60 m³/h 96 tin-plated Information DC axial fans DC centrifugal fans 55 max. m3/h DC centrifugal fans Series RL 90 N 121 x 121 x 37 mm – Material: Scroll housing: GRP1) Impeller: GRP1) Housing base: Sheet steel – Direction of air flow: Axial: Intake Centrifugal: Exhaust – Connection: Via single wires AWG 22, TR 64 – Highlights: Forwards-curved impeller – Mass: 420 g 1) Fibreglass-reinforced plastic – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Protection against moisture - Protection against salt fog - Type of protection: IP 54 / IP 68 Air flow Air flow Nominal voltage Voltage range Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type RL 90-18/12 N RL 90-18/14 NG RL 90-18/14 N RL 90-18/18 NH Subject to alternations m3/h CFM VDC VDC Bel(A) 40 23,5 12 7...15 5,8 40 23,5 40 23,5 24 12...28 5,8 24 12...28 5,8 55 32,4 48 36...53 6,9 / Watts rpm °C Hours Hours 6,3 2 500 -30...+75 62 500 / 27 500 105 000 ➀ 5,6 2 500 -20...+75 62 500 / 27 500 105 000 ➀ 5,6 2 500 -30...+75 62 500 / 27 500 105 000 ➀ 14,7 3 500 -30...+65 32 500 / 17 500 55 000 ➁ DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories 67,4 +0,4 Pa 0,8 [in H2O] 2 0, 6 200 175 150 125 1 100 75 50 25 0, 4 0, 2 0 5 10 15 20 25 30 CFM 10 20 30 40 50 m³/h 6+1 310 +10 97 71,4 +0,2 2,5 60,3 3,5 45 37,3+0,7 2 26,5 57,6 80 104,8 +0,2 120,6 54 tin-plated 100,8 +0,2 112,7 +0,2 120,6 4,2 +0,4 15,5 30+_ 0,3 Screw clip M4 or 8-32UNC. Screw-in depth max. 12.5 min. 9.0 12±0,5 97 6+ 0,3 Representatives 80 max. m3/h DC centrifugal fans Series RLF 100 127 x 127 x 25 mm – Material: Scroll housing: GRP1) Impeller: GRP1) Housing base: Sheet steel – Direction of air flow: Axial: Intake Centrifugal: Exhaust – Connection: Via single wires AWG 22, TR 64 – Highlights: Optional protective cap for outlet opening Backwards-curved impeller – Mass: 320 g – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Protection against moisture - Type of protection: IP 54 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Voltage range Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type RLF 100-11/12 RLF 100-11/14 RLF 100-11/18 m3/h CFM 64 37,7 64 37,7 64 37,7 VDC VDC Bel(A) 12 8...15 6,4 24 16...30 6,4 48 36...60 6,4 High speed models with Open Collector Tacho and PWM speed control. RLF 100-11/12/2 HP-200 80 47,1 12 10...13,2 7,5 RLF 100-11/18/2 HP-182 80 Subject to alternations 47,1 48 43...53 7,5 / Watts rpm °C Hours Hours 8,0 5 100 -20...+75 80 000 / 30 000 135 000 ➀ 8,0 5 100 -20...+75 80 000 / 30 000 135 000 ➀ 8,6 5 100 -20...+75 80 000 / 30 000 135 000 ➀ 18,6 6 400 -20...+60 72 500 / 45 000 122 500 ➁ 17,0 6 400 -20...+70 72 500 / 35 000 122 500 ➁ Pa [in H O] 2 0,4 0,8 1,2 1,6 2,0 600 2 500 400 1 300 200 100 0 10 20 30 4 0 CFM 10 20 30 40 50 60 m³/h 98 tin-plated Information DC axial fans DC centrifugal fans 55 max. m3/h DC centrifugal fans Series RG 90 N 135 x 135 x 38 mm – Material: Scroll housing: GRP1) – Possible special versions: Impeller: GRP1) (See chapter DC fans - specials) Housing base: Sheet steel - Speed signal – Direction of air flow: Axial: Intake - Go / No-go alarm Centrifugal: Exhaust - Alarm with limit speed – Connection: Via single wires AWG 22, - External temperature sensor TR 64 - Internal temperature sensor 48 V model: Flat plug - PWM control input 6.3 x 0.8 mm for protective earth - Analogue control input – Highlights: Forwards-curved impeller - Protection against moisture – Mass: 440 g - Protection against salt fog - Type of protection: IP 54 / IP 68 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Voltage range Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type RG 90-18/12 N RG 90-18/14 NG RG 90-18/14 N RG 90-18/18 N Subject to alternations m3/h CFM VDC VDC Bel(A) 55 32,4 12 7...15 5,5 55 32,4 55 32,4 24 12...28 5,5 24 12...28 5,5 55 32,4 48 36...56 5,5 / Watts rpm °C Hours Hours 6,7 2 200 -30...+75 62 500 / 27 500 105 000 ➀ 6,2 2 200 -10...+75 62 500 / 27 500 105 000 ➀ 6,2 2 200 -30...+75 62 500 / 27 500 105 000 ➀ 6,1 2 200 -30...+75 62 500 / 27 500 105 000 ➀ DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Pa [in H O] 2 Accessories 0,3 100 1 80 60 40 20 0, 2 0,1 0 5 10 15 20 25 30 CFM 10 20 30 40 50 m³/h tin-plated 99 Representatives max. 137 m3/h DC centrifugal fans Series RG 125 N 180 x 180 x 40 mm – Material: Scroll housing: GRP1) – Possible special versions: Impeller: GRP1) (See chapter DC fans - specials) Housing base: Sheet steel - Speed signal – Direction of air flow: Axial: Intake - Go / No-go alarm Centrifugal: Exhaust - Alarm with limit speed – Connection: Via single wires AWG 22, - External temperature sensor TR 64 - Internal temperature sensor 48 V model: Flat plug - PWM control input 6.3 x 0.8 mm for protective earth - Analogue control input – Highlights: Backwards-curved impeller - Protection against moisture – Mass: 730 g - Protection against salt fog - Type of protection: IP 54 / IP 68 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Voltage range Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type RG 125-19/12 NM RG 125-19/12 N RG 125-19/14 NM RG 125-19/14 N RG 125-19/18 N RG 125-19/18 NH Subject to alternations m3/h CFM 60,0 35,3 87,5 51,5 60,0 35,3 87,5 51,5 87,5 51,5 137 80,6 VDC VDC Bel(A) 12 7...15 4,8 12 7...15 5,8 24 12...28 4,8 24 12...28 5,8 48 36...56 5,8 48 36...56 7,0 / Watts rpm °C Hours Hours 2,0 1 750 -30...+75 70 000 / 30 000 117 500 ➀ 5,2 2 550 -30...+75 62 500 / 27 500 105 000 ➁ 2,0 1 750 -30...+75 70 000 / 30 000 117 500 ➀ 4,9 2 550 -30...+75 62 500 / 27 500 105 000 ➁ 4,8 2 550 -30...+75 62 500 / 27 500 105 000 ➁ 19,0 4 000 -20...+70 55 000 / 27 500 92 500 ➂ Pa [in H O] 2 1, 2 420 3 360 300 240 180 2 120 1 60 0, 8 0, 4 0 20 40 60 8 0 CFM 20 40 60 80 100 120 m³/h 100 tin-plated Information DC axial fans DC centrifugal fans max. 209 m3/h DC centrifugal fans Series RG 160 N 220 x 220 x 56 mm – Material: Scroll housing: GRP1) – Possible special versions: Impeller: GRP1) (See chapter DC fans - specials) Housing base: Sheet steel - Speed signal – Direction of air flow: Axial: Intake - Go / No-go alarm Centrifugal: Exhaust - Alarm with limit speed – Connection: Via single wires AWG 22, - External temperature sensor TR 64 - Internal temperature sensor 48 V model: Flat plug - PWM control input 6.3 x 0.8 mm for protective earth - Analogue control input – Highlights: Backwards-curved impeller - Protection against moisture – Mass: 1,4 kg - Protection against salt fog - Type of protection: IP 54 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Voltage range Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type m3/h CFM VDC VDC Bel(A) RG 160-28/12 NM 139 81 12 7...14 5,6 RG 160-28/12 N 209 123 12 7,5...14 6,6 RG 160-28/14 NM 139 81 24 12...28 5,6 RG 160-28/14 N 209 123 24 12...28 6,6 RG 160-28/18 N 209 123 48 28...60 6,6 Subject to alternations / Watts rpm °C Hours Hours 7,5 1 900 -20...+70 80 000 / 40 000 135 000 ➀ 21,0 2 850 -20...+70 70 000 / 35 000 117 500 ➁ 7,0 1 900 -20...+70 80 000 / 40 000 135 000 ➀ 20,0 2 850 -20...+70 70 000 / 35 000 117 500 ➁ 20,0 2 850 -20...+70 70 000 / 35 000 117 500 ➁ DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Pa [in H2O] Accessories 0,2 0,4 0,6 0,8 1,0 1 ,2 2 350 300 250 200 1 150 100 50 0 20 40 60 80 CFM 25 50 75 100 125 150 m³/h tin-plated 101 Representatives max. 444 m3/h DC centrifugal fans Series RG 160 NTD 220 x 220 x 56 mm – Material: Scroll housing: GRP1) – Possible special versions: Impeller: GRP1) (See chapter DC fans - specials) Housing base: Sheet steel - Speed signal – Direction of air flow: Axial: Intake - Go / No-go alarm Centrifugal: Exhaust - Alarm with limit speed – Connection: Via single wires AWG 22, TR 64 - External temperature sensor 48 V model: Flat plug - Internal temperature sensor 6.3 x 0.8 mm for protective earth - PWM control input – Highlights: 3-phase fan drive with very - Analogue control input smooth running - Protection against moisture Backwards-curved impeller - Type of protection: IP 54 – Mass: 1,4 kg 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Voltage range Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type m3/h CFM VDC VDC Bel(A) / Watts rpm °C Hours Hours min. RG 160-28/14 NTD... max. RG 160-28/14 NTD RG 160-28/14 NTDH 59 35 308 181 308 181 370 218 — 24 16...28 7,5 24 16...28 7,5 24 16...28 7,8 2,0 64,0 64,0 101,0 800 4 200 4 200 5 000 -20...+60 -20...+60 -20...+60 ➀ 55 000 / 35 000 92 500 ➁ 55 000 / 35 000 92 500 ➁ 50 000 / 32 500 85 000 ➂ min. RG 160-28/18 NTD... max. 59 35 308 181 — 48 38...57 7,5 2,0 800 ➀ 59,0 -20...+70 4 200 55 000 / 27 500 92 500 ➁ RG 160-28/18/2 N/2 TDHHP* Subject to alternations 444 261 48 36...60 8,5 159 6 000 -20...+65 40 000 / 22 500 67 500 ➃ Models RG 160-28/14 NTD... and RG 160-28/18 NTD... are available in customer-specific, custom-developed variants only. The data specified here are technically feasible benchmark values. The fans can be specially adapted to your application with signal outputs and control inputs. *The specific service life is valid when an external capacitor is wired between the plus and minus wires. Please note the wiring suggestion. Pa [in H2O] Pa [in H2O] 2 700 600 0,4 0,8 1,2 1,6 2,0 2 ,4 500 400 300 200 100 1 nmin 0 30 50 4 1400 0,8 1,6 2,4 3,2 4,0 4,8 1200 1000 3 800 600 400 200 0 50 100 150 200 250 CFM 100 200 300 400 m³/h n max 60 90 120 150 CFM 100 150 200 250 m³/h 102 tin-plated Information DC axial fans DC centrifugal fans max. 930 m3/h DC centrifugal fans Series RG 190 TD 225 x 225 x 85 mm – Material: Scroll housing: GRP1) – Possible special versions: Impeller: GRP1) (See chapter DC fans - specials) – Direction of air flow: Axial: Intake, Centrifugal: Exhaust - Speed signal – Direction of rotation: Clockwise, seen on rotor - Go / No-go alarm – Connection: Via single wires AWG 18, 20 or - Alarm with limit speed AWG 22, TR 64, speed signal - External temperature sensor and control input AWG 22 - Internal temperature sensor – Highlights: 3-phase fan drive with very - PWM control input smooth running and high - Analogue control input efficiency - Multi-option control input Backwards-curved RadiCal - Protection against moisture impeller - Protection against salt fog – Mass: 1210 g - Type of protection: IP 54 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Voltage range Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type m3/h CFM VDC VDC Bel(A) / Watts rpm °C Hours Hours RG 190-39/14/2 TDMLO 630 371 RG 190-39/14/2 TDMO 820 482 24 16...30 7,6 24 16...36 7,9 54 3 000 -20...+60 55 000 / 35 000 92 500 ➀ 113 3 900 -20...+65 52 500 / 30 000 87 500 ➁ RG 190-39/18/2 TDMLO* 630 371 48 36...57 7,6 52 3 000 -20...+65 55 000 / 30 000 92 500 ➀ RG 190-39/18/2 TDMO 820 482 48 36...72 7,9 113 3 900 -20...+65 52 500 / 30 000 87 500 ➁ RG 190-39/18/2 TDO 930 547 48 36...72 8,3 140 4 400 -20...+65 40 000 / 22 500 67 500 ➂ * provisional Subject to alternations Speed control range from 800 rpm at 7 % PWM up to nominal speed at > 90 % PWM. Standstill at 0 % PWM, standstill if control cable is interrupted. DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans 2 3,5 [in H O] [Pa] Accessories 201 +0,5 900 3 800 3 700 2 1,5 600 2 500 400 1 1,5 300 1 200 0,5 100 0 100 200 300 400 500 [CFM] 200 400 600 800 [m3/h] Guard grilles p. 245 Ø133 265+- 0,5 6 +1 350 +10 tin-plated 6,0 +0,3 79,5+1,0 103 Representatives max. 1280 m3/h DC centrifugal fans Series RG 220 TD 270 x 270 x 99 mm – Material: Scroll housing: GRP1) Impeller: GRP1) – Direction of air flow: Axial: Intake Centrifugal: Exhaust – Direction of rotation: Clockwise, seen on rotor – Connection: Via single wires AWG 18, 20 or AWG 22, TR 64, speed signal and control input AWG 22 – Highlights: 3-phase fan drive with very smooth running and high efficiency Backwards-curved impeller – Mass: 1870 g 1) Fibreglass-reinforced plastic – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Protection against moisture - Protection against salt fog - Type of protection: IP 54 Air flow Air flow Nominal voltage Voltage range Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type RG 220-44/14/2 TDMO* RG 220-44/18/2 TDMO* RG 220-44/18/2 TDO* * provisional Subject to alternations m3/h CFM 1090 641 1090 641 1280 753 VDC VDC Bel(A) 24 16...36 7,7 48 36...72 7,7 48 36...72 8,0 / Watts rpm °C Hours Hours 82 3 000 -20...+55 75 000 / 52 500 127 500 ➀ 80 3 000 -20...+55 75 000 / 52 500 127 500 ➀ 140 3 500 -20...+55 55 000 / 40 000 92 500 ➁ Speed control range from 800 rpm at 7 % PWM up to nominal speed at > 90 % PWM. Standstill at 0 % PWM, standstill if control cable is interrupted. [Pa] [in H O] 2 6 +1 350 +10 243,2 +0,5 0,25 0,5 0,75 1 1,25 1,5 1,75 2 2,25 2 600 500 1 400 300 200 100 0 100 200 300 400 500 600 700 [CFM] 200 400 600 800 1000 1200 [m3/h] 104 Guard grilles p. 245 Ø166 305+- 0,5 tin-plated 7,0+0,3 92 +1,0 Information DC axial fans DC centrifugal fans max. 1450 m3/h DC centrifugal fans Series RG 225 TD 270 x 270 x 119 mm – Material: Scroll housing: GRP1) – Possible special versions: Impeller: GRP1) (See chapter DC fans - specials) – Direction of air flow: Axial: Intake, Centrifugal: Exhaust - Speed signal – Direction of rotation: Clockwise, seen on rotor - Go / No-go alarm – Connection: Via single wires AWG 18, 20 or - Alarm with limit speed AWG 22, TR 64, speed signal - External temperature sensor and control input AWG 22 - Internal temperature sensor – Highlights: 3-phase fan drive with very - PWM control input smooth running and high - Analogue control input efficiency - Protection against moisture Backwards-curved RadiCal - Protection against salt fog impeller - Type of protection: IP 54 – Mass: 1750 g 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Voltage range Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type m3/h CFM VDC VDC Bel(A) / Watts rpm °C Hours Hours RG 225-55/14/2 TDMLO 1040 612 24 16...36 7,3 65 2 400 -20...+55 72 500 / 52 500 122 500 ➀ RG 225-55/18/2 TDMLO* 1040 612 48 36...72 7,3 65 2 400 -20...+55 72 500 / 52 500 122 500 ➀ RG 225-55/18/2 TDMO 1210 712 48 36...72 7,9 116 2 800 -20...+55 55 000 / 40 000 92 500 ➁ NEW RG 225-55/18/2 TDO 1450 853 48 36...60 8,1 192 3 300 -20...+40 30 000 / 30 000 50 000 ➂ * provisional Subject to alternations Speed control range from 800 rpm at 7 % PWM up to nominal speed at > 90 % PWM. Standstill at 0 % PWM, standstill if control cable is interrupted. The specific service life is valid when an external capacitor is wired between the plus and minus wires. Please note the wiring suggestion. DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans 6 +1 350 +10 Accessories 243,2 +0,5 Guard grilles p. 245 Ø158 305+- 0,5 tin-plated 7,0 +0,3 112 + 1,0 105 Representatives max. 220 m3/h DC centrifugal fans Series RET 97 TD Ø 97 x 41 mm – Material: Impeller: Galvanised sheet – Possible special versions: steel (See chapter DC fans - specials) – Direction of air flow: Axial: Intake, Centrifugal: Exhaust - Speed signal – Direction of rotation: Clockwise, seen on rotor - Go / No-go alarm – Connection: Via single wires AWG 18, 20 or - Alarm with limit speed AWG 22, TR 64, speed signal - External temperature sensor and control input AWG 22 - Internal temperature sensor – Highlights: 3-phase fan drive with very - PWM control input smooth running and high - Analogue control input efficiency - Protection against moisture Forwards-curved impeller Fan requires a scroll housing – Mass: 430 g Air flow Air flow Nominal voltage Voltage range Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type RET 97-25/14/2 TDP RET 97-25/18/2 TDP Subject to alternations m3/h CFM 220 129 220 129 VDC VDC Bel(A) 24 16...36 8,1 48 36...60 8,1 / Watts rpm °C Hours Hours 77 6 000 -20...+60 80 000 / 50 000 135 000 ➀ 76 6 000 -20...+60 80 000 / 50 000 135 000 ➀ Speed control range from 800 rpm at 7 % PWM up to nominal speed at > 90 % PWM. Standstill at 0 % PWM, standstill if control cable is interrupted. The specific service life is valid when an external capacitor is wired between the plus and minus wires. Please note the wiring suggestion. All nominal data were measured in the scroll housing. 6 +1 310 +10 Pa [in H2O] ø 47,1 ø 58,3 97 2, 4 800 1 700 600 500 400 300 200 100 1, 6 0, 8 0 25 50 75 100 125 CFM 50 100 150 200 m³/h 106 Inlet nozzles from p. 248 tin-plated M4 (4x) 24,4 40,5 +1 7,95 + 1 Information DC axial fans DC centrifugal fans max. 104 m3/h DC centrifugal fans Series REF 100 Ø 104 x 25 mm – Material: Impeller: GRP1) – Direction of air flow: Axial: Intake Centrifugal: Exhaust – Direction of rotation: Clockwise, seen on rotor – Connection: Via single wires AWG 22, TR 64 – Highlights: Backwards-curved impeller – Mass: 160 g – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Protection against moisture - Type of protection: IP 54 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Voltage range Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type REF 100-11/12 REF 100-11/14 REF 100-11/18 REF 100-11/18 H Subject to alternations m3/h CFM 86 50,6 86 50,6 86 50,6 104 61,2 VDC VDC Bel(A) 12 8...15 6,3 24 16...30 6,3 48 36...60 6,3 48 36...56 6,9 / Watts rpm °C Hours Hours 7,5 5 400 -20...+75 80 000 / 30 000 135 000 ➀ 7,5 5 400 -20...+75 80 000 / 30 000 135 000 ➀ 8,2 5 400 -20...+75 80 000 / 30 000 135 000 ➀ 14,8 6 700 -20...+70 67 500 / 32 500 115 000 ➁ The air flow and noise level of the centrifugal fans without external housing depend on their individual installation conditions. The stated air flow and noise level were recorded under the following measurement parameters: Centrifugal fan mounted on a foundation plate 127 x 127 mm. Cover plate 127 x 127 mm, with an air inlet opening Ø 70 mm, arranged concentrically to the impeller. DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Pa [in H O] 2 Accessories 1, 6 1,2 2 500 400 1 300 200 100 0, 8 0, 4 0 10 20 30 40 50 CFM 20 40 60 80 100 m³/h tin-plated 107 6 deep Representatives max. 190 m3/h DC centrifugal fans Series RER 101 Ø 101 x 52 mm – Material: Impeller: GRP1) – Direction of air flow: Axial: Intake Centrifugal: Exhaust – Direction of rotation: Clockwise, seen on rotor – Connection: Via single wires AWG 22, TR 64 – Highlights: Backwards-curved impeller – Mass: 305 g – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Protection against moisture 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Voltage range Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type RER 101-36/12 NH RER 101-36/12 NHH RER 101-36/14 NHH RER 101-36/18 NHH Subject to alternations m3/h CFM 162 95 190 112 190 112 190 112 VDC VDC Bel(A) 12 9...13,6 6,9 12 9...13,6 7,2 24 18...27,2 7,2 48 36...60 7,2 / Watts rpm °C Hours Hours 13,0 5 000 -20...+70 65 000 / 32 500 110 000 ➁ 20,5 6 000 -20...+70 60 000 / 30 000 102 500 ➀ 22,5 6 050 -20...+70 60 000 / 30 000 102 500 ➀ 19,4 5 850 -20...+70 60 000 / 30 000 102 500 ➀ The air flow and noise level of the centrifugal fans without external housing depend on their individual installation conditions. The stated air flow and noise level were recorded under the following measurement parameters: Centrifugal fan mounted on a foundation plate 148 x 148 mm. Cover plate 148 x 148 mm, with an air inlet opening Ø 66 mm, arranged concentrically to the impeller. Pa [in H2O] 1 400 1,5 300 2 1, 0 200 0, 5 100 0 20 40 60 80 100 CFM 25 50 75 100 125 150 m³/h 108 Inlet nozzles from p. 248 tin-plated 36,7 O 100 -+0,5 O 60 -+0,2 M 4 (3x) 10 deep 6,0 +- 0,2 7,0 +- 0,45 8,0 +- 0,55 50,25 +- 0,95 51,7+- 0,9 Information DC axial fans DC centrifugal fans max. 390 m3/h DC centrifugal fans Series RER 120 TD Ø 120 x 54 mm – Material: Impeller: GRP1) – Direction of air flow: Axial: Intake Centrifugal: Exhaust – Direction of rotation: Clockwise, seen on rotor – Connection: Via single wires AWG 18, 20 or AWG 22, TR 64, speed signal and control input AWG 22 – Highlights: 3-phase fan drive with very smooth running and high efficiency Backwards-curved impeller – Mass: 430 g – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Protection against moisture 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Voltage range Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type m3/h CFM VDC VDC Bel(A) / Watts rpm °C Hours Hours RER 120-26/14/2 TDMP* 320 188 RER 120-26/14/2 TDP 377 222 24 16...32 tbd 24 16...32 8,2 51 5 200 -20...+60 60 000 / 37 500 102 500 ➀ 78 6 100 -20...+60 55 000 / 35 000 92 500 ➁ RER 120-26/18/2 TDMP* RER 120-26/18/2 TDP * provisional Subject to alternations 320 188 390 230 48 36...60 tbd 48 36...60 8,3 51 5 200 -20...+60 57 500 / 35 000 92 6 300 -20...+60 50 000 / 30 000 Speed control range from 800 rpm at 7 % PWM up to nominal speed at > 90 % PWM. Standstill at 0 % PWM, standstill if control cable is interrupted. The specific service life is valid when an external capacitor is wired between the plus and minus wires. Please note the wiring suggestion. 97 500 ➀ 85 000 ➂ The air flow and noise level of the centrifugal fans without external housing depend on their individual installation conditions. The stated air flow and noise level were recorded under the following measurement parameters: Centrifugal fan mounted on a foundation plate 140 x 140 mm. Cover plate 140 x 140 mm, with an air inlet opening Ø 94,4 mm, arranged concentrically to the fan impeller. DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Pa [in H2O] Accessories 3 600 2 500 1,6 400 1 300 0, 8 200 100 0 50 100 100 200 150 200 CFM 300 m³/h Inlet nozzles from p. 248 tin-plated 109 max. 8 deep Representatives max. 250 m3/h DC centrifugal fans Ø 120 mm – Material: – Number of blades: – Direction of rotation: – Type of protection: – Insulation class: – Mounting position: – Condensate discharges: – Operation mode: – Bearings: Impeller: PA 6.6 plastic, fibreglass-reinforced Rotor: Galvanised 9 Clockwise, seen on rotor IP 20 "B" Any None Continuous operation (S1) Maintenance-free ball bearings Curve Nominal voltage Voltage range Air flow Speed / rpm Input power Current draw Sound power level Perm. amb. temp. Technical features and electrical connections Nominal data Type R1G 120 R1G 120 Subject to alternations Motor M1G 045-BE A M1G 045-BE A VDC VDC m3/h rpm 24 16-28 250 4060 48 36-57 250 4060 W A dB(A) °C 26 1,20 62 -25..+60 26 0,60 62 -25..+60 p. 255 / G) p. 255 / G) Curve: UN = nominal voltage (24 V /48 V) UR = overvoltage (28 V / 57 V) n Ped LpA ηtL rpm W dB(A) % A 1’ 4520 36 65 — A 2’ 4500 36 64 27 A 3’ 4540 36 61 45 A 4’ 4750 32 64 39 A 1 4060 26 62 — A 2 4000 26 61 27 A 3 4050 26 58 45 A 4 4200 23 61 39 A 5 3270 14 56 — A 6 3250 14 55 27 A 7 3280 14 53 45 A 8 3400 13 56 39 110 Air performance measured as per: ISO 5801, Installation category A, with ebm-papst inlet nozzle without protection against accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted! For detailed information see http://www.ebmpapst.com/general conditions Information DC axial fans DC centrifugal fans DC fans - specials – Technical features: – Cable exit: – Protection class: – Product conforming to standards: – Approvals: See electrical connections p. 255 Axial I EN 60950-1 A (48 VDC) CCC Mass centrifugal fans Centrifugal fans R1G 120-AD13 -02 R1G 120-AD11 -02 kg Inlet nozzle (long) 0,5 96120-2-4013 0,5 96120-2-4013 Lead tips crimped Depth of screw max. 4 mm ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Representatives Guard grilles from p. 238 Electrical connections from p. 255 111 max. 166 m3/h DC centrifugal fans Series RER 125 N Ø 138 x 35 mm – Material: Impeller: GRP1) – Direction of air flow: Axial: Intake Centrifugal: Exhaust – Direction of rotation: Clockwise, seen on rotor – Connection: Via single wires AWG 22, TR 64 – Highlights: Backwards-curved impeller – Mass: 320 g 1) Fibreglass-reinforced plastic – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Protection against moisture - Protection against salt fog - Type of protection: IP 54 / IP 68 Air flow Air flow Nominal voltage Voltage range Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type RER 125-19/12 N RER 125-19/14 N RER 125-19/14 NH RER 125-19/18 N Subject to alternations m3/h CFM 110 64,7 110 64,7 166 97,7 110 64,7 VDC VDC Bel(A) 12 7...15 5,7 24 12...28 5,7 24 12...28 7,0 48 36...56 5,7 / Watts rpm °C Hours Hours 4,6 2 650 -30...+75 62 500 / 27 500 105 000 ➀ 4,3 2 650 -30...+75 62 500 / 27 500 105 000 ➀ 13,0 4 000 -20...+70 55 000 / 27 500 92 500 ➁ 4,2 2 650 -30...+75 62 500 / 27 500 105 000 ➀ The air flow and noise level of the centrifugal fans without external housing depend on their individual installation conditions. The stated air flow and noise level were recorded under the following measurement parameters: Centrifugal fan mounted on a foundation plate 120 x 120 mm. Cover plate 120 x 120 mm, with an air inlet opening Ø 86 mm, arranged concentrically to the impeller. [in H O] 2 Pa 0, 8 0,6 2 200 150 1 100 50 0,4 0, 2 0 20 40 60 80 CFM 25 50 75 100 125 m³/h 112 5 deep tin-plated Information DC axial fans DC centrifugal fans max. 565 m3/h DC centrifugal fans Series RER 133 TD Ø 133 x 91 mm – Material: Impeller: GRP1) – Direction of air flow: Axial: Intake Centrifugal: Exhaust – Direction of rotation: Clockwise, seen on rotor – Connection: Via single wires AWG 18, 20 or AWG 22, TR 64, speed signal and control input AWG 22 – Highlights: 3-phase fan drive with very smooth running and high efficiency Backwards-curved impeller – Mass: 890 g 1) Fibreglass-reinforced plastic – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Multi-option control input - Protection against moisture - Protection against salt fog - Type of protection: IP 54 Air flow Air flow Nominal voltage Voltage range Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type m3/h CFM VDC VDC Bel(A) / Watts rpm °C Hours Hours RER 133-41/14/2 TDMP 460 271 RER 133-41/14/2 TDP* 565 332 24 16...30 tbd 24 16...36 tbd 58 5 000 -20...+65 72 500 / 40 000 122 500 ➀ 90 6 000 -20...+65 70 000 / 37 500 117 500 ➁ RER 133-41/18/2 TDMP* 460 271 48 36...57 tbd 50 5 000 -20...+65 72 500 / 40 000 122 500 ➀ RER 133-41/18/2 TDP 565 332 48 36...72 8,2 87 6 000 -20...+65 70 000 / 37 500 117 500 ➁ * provisional Subject to alternations Speed control range from 800 rpm at 7 % PWM up to nominal speed at > 90 % PWM. Standstill at 0 % PWM, standstill if control cable is interrupted. The air flow and noise level of the centrifugal fans without external housing depend on their individual installation conditions. The stated air flow and noise level were recorded under the following measurement parameters: Centrifugal fan mounted on a foundation plate 140 x 140 mm. Cover plate 140 x 140 mm, with an air inlet opening Ø 87 mm, arranged concentrically to the impeller. DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans [in H O] 2 Pa Accessories 2, 4 2 600 1 400 200 1, 6 0,8 0 50 100 150 200 250 300 CFM 100 200 300 400 500 m³/h Inlet nozzles from p. 248 tin-plated 113 max. 8 deep Representatives max. 255 m3/h DC centrifugal fans Series RER 160 N Ø 165 x 51 mm – Material: Impeller: GRP1) – Direction of air flow: Axial: Intake Centrifugal: Exhaust – Direction of rotation: Counter-clockwise, seen on rotor – Connection: Via single wires AWG 22, TR 64 – Highlights: Backwards-curved impeller – Mass: 590 g 1) Fibreglass-reinforced plastic – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Protection against moisture - Protection against salt fog - Type of protection: IP 54 Air flow Air flow Nominal voltage Voltage range Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type RER 160-28/12 N RER 160-28/14 N RER 160-28/18 N Subject to alternations m3/h CFM 255 150 255 150 255 150 VDC VDC Bel(A) 12 7...14 6,4 24 12...28 6,4 48 28...60 6,4 / Watts rpm °C Hours Hours 19,0 3 000 -20...+70 75 000 / 37 500 127 500 ➀ 19,0 3 000 -20...+70 75 000 / 37 500 127 500 ➀ 19,0 3 000 -20...+70 75 000 / 37 500 127 500 ➀ The air flow and noise level of the centrifugal fans without external housing depend on their individual installation conditions. The stated air flow and noise level were recorded under the following measurement parameters: Centrifugal fan mounted on a foundation plate 260 x 260 mm. Cover plate 260 x 260 mm, with an air inlet opening Ø 100 mm, arranged concentrically to the impeller. [in H O] 2 Pa max. 8 deep 0, 8 0, 6 1 200 150 100 50 0, 4 0,2 0 20 40 60 80 100 120 CFM 50 100 150 200 m³/h 114 Inlet nozzles from p. 248 tin-plated Information DC axial fans max. 370 m3/h DC centrifugal fans Series RER 160 NTD Ø 165 x 51 mm – Material: Impeller: GRP1) – Direction of air flow: Axial: Intake Centrifugal: Exhaust – Direction of rotation: Clockwise, seen on rotor – Connection: Via single wires AWG 22, TR 64 – Highlights: 3-phase fan drive with very smooth running and high efficiency Backwards-curved impeller – Mass: 590 g – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Protection against moisture - Type of protection: IP 54 1) Fibreglass-reinforced plastic DC centrifugal fans Air flow Air flow Nominal voltage Voltage range Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans Nominal data Type m3/h CFM VDC VDC Bel(A) / Watts rpm °C Hours Hours RER 160-28/14 N/2 TDA 370 217 24 16...28 7,4 51 4 200 -20...+60 55 000 / 35 000 92 500 ➁ RER 160-28/18 N/2 TDHHP* 305 298 48 36...60 8,5 142 6 000 -20...+65 40 000 / 22 500 67 500 ➂ min. RER 160-28/18 NTD... max. Subject to alternations 66 39 354 98 — 48 38...57 7,4 2,0 800 ➀ 43,0 -20...+70 4 200 55 000 / 27 500 92 500 ➁ Model RER 160-28/18 NTD... is available in customer-specific, custom-developed variant only. The data specified here are technically feasible benchmark values. The fans can be specially adapted to your application with signal outputs and control inputs. * The specific service life is valid when an external capacitor is wired between the plus and minus wires. Please note the wiring suggestion. The air flow and noise level of the centrifugal fans without external housing depend on their individual installation conditions. The stated air flow and noise level were recorded under the following measurement parameters: Centrifugal fan mounted on a foundation plate 260 x 260 mm. Cover plate 260 x 260 mm, with an air inlet opening Ø 100 mm, arranged concentrically to the impeller. [in H O] 2 Pa Pa [in H2O] 1,6 2 500 400 4,0 3,2 3 1000 800 600 400 200 2,4 1,6 0, 8 0 50 100 150 200 250 CFM 100 200 300 400 m³/h 1, 2 300 0,8 200 0, 4 100 1 nmin 0 50 100 150 50 100 150 200 250 n max CFM m³/h tin-plated max. 8 deep Inlet nozzles from p. 248 115 AC centrifugal fans Accessories Representatives max. 800 m3/h DC centrifugal fans Series REF 175 TD Ø 175 x 55 mm – Material: Impeller: Galvanised sheet steel – Possible special versions: – Direction of air flow: Axial: Intake, Centrifugal: Exhaust (See chapter DC fans - specials) – Direction of rotation: Clockwise, seen on rotor - Speed signal – Connection: Via single wires AWG 18, 20 or - Go / No-go alarm AWG 22, TR 64, speed signal - Alarm with limit speed and control input AWG 22 - External temperature sensor – Highlights: 3-phase fan drive with very - Internal temperature sensor smooth running and high - PWM control input efficiency - Analogue control input Backwards-curved impeller - Multi-option control input – Mass: 930 g - Protection against moisture 1) Fibreglass-reinforced plastic - Type of protection: IP 54 Air flow Air flow Nominal voltage Voltage range Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type REF 175-30/18/2 TDP Subject to alternations m3/h CFM 800 470 VDC VDC Bel(A) 48 36 ... 72 8,3 / Watts rpm °C Hours Hours 144 4 400 -20...+60 65 000 / 37 500 110 000 ➀ Speed control range from 800 rpm at 7 % PWM up to nominal speed at > 90 % PWM. Standstill at 0 % PWM, standstill if control cable is interrupted. The air flow and noise level of the centrifugal fans without external housing depend on their individual installation conditions. The stated air flow and noise level were recorded under the following measurement parameters: Centrifugal fan mounted on a foundation plate 180 x 180 mm. Cover plate 180 x 180 mm, with an air inlet opening Ø 125,5 mm, arranged concentrically to the impeller. Pa [in H O] 2 max. 8 deep 1,6 1 600 500 400 300 200 100 0, 8 0 100 200 300 400 500 CFM 200 400 600 800 m³/h 116 Inlet nozzles from p. 248 tin-plated Information DC axial fans DC centrifugal fans max. 980 m3/h DC centrifugal fans Series RER 175 TD Ø 175 x 69 mm – Material: Impeller: GRP1) – Direction of air flow: Axial: Intake Centrifugal: Exhaust – Direction of rotation: Clockwise, seen on rotor – Connection: Via single wires AWG 18, 20 or AWG 22, TR 64, speed signal and control input AWG 22 – Highlights: 3-phase fan drive with very smooth running and high efficiency Backwards-curved impeller – Mass: 775 g 1) Fibreglass-reinforced plastic – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Multi-option control input - Protection against moisture - Protection against salt fog - Type of protection: IP 54 Air flow Air flow Nominal voltage Voltage range Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type m3/h CFM VDC VDC Bel(A) / Watts rpm °C Hours Hours RER 175-42/14/2 TDMLP 600 353 RER 175-42/14/2 TDMP 865 509 24 16...30 7,3 24 16...36 8,2 48 3 400 -20...+65 72 500 / 40 000 122 500 ➀ 110 4 800 -20...+65 70 000 / 40 000 117 500 ➁ RER 175-42/18/2 TDMLP 600 353 48 36...57 7,3 46 3 400 -20...+65 72 500 / 40 000 122 500 ➀ RER 175-42/18/2 TDMP* 865 509 48 36...72 8,2 110 4 800 -20...+65 70 000 / 40 000 117 500 ➁ RER 175-42/18/2 TDP 980 577 48 36...72 8,5 166 5 400 -20...+65 60 000 / 32 500 102 500 ➂ * vorläufig Subject to alternations Speed control range from 800 rpm at 7 % PWM up to nominal speed at > 90 % PWM. Standstill at 0 % PWM, standstill if control cable is interrupted. The air flow and noise level of the centrifugal fans without external housing depend on their individual installation conditions. The stated air flow and noise level were recorded under the following measurement parameters: Centrifugal fan mounted on a foundation plate 180 x 180 mm. Cover plate 180 x 180 mm, with an air inlet opening Ø 125,5 mm, arranged concentrically to the impeller. DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans 6+1 425 +10 3,2 [in H2O] Accessories ø 58 +0,1 ø 72+0,3 ø175 +0,5 Pa 2, 4 3 800 2 600 400 1 200 1, 6 0, 8 0 100 200 300 400 500 CFM 200 400 600 800 m³/h Inlet nozzles from p. 248 tin-plated M4 (4x) max. 8 deep 42 69±1 6,8+0,8 117 Representatives max. 970 m3/h DC centrifugal fans Series RER 190 TD Ø 190 x 69 mm – Material: Impeller: GRP1) – Possible special versions: – Direction of air flow: Axial: Intake, Centrifugal: Exhaust (See chapter DC fans - specials) – Direction of rotation: Clockwise, seen on rotor - Speed signal – Connection: Via single wires AWG 18, 20 or - Go / No-go alarm AWG 22, TR 64, speed signal - Alarm with limit speed and control input AWG 22 - External temperature sensor – Highlights: 3-phase fan drive with very - Internal temperature sensor smooth running and high - PWM control input efficiency - Analogue control input Backwards-curved RadiCal - Multi-option control input impeller - Protection against moisture – Mass: 870 g - Protection against salt fog 1) Fibreglass-reinforced plastic - Type of protection: IP 54 Air flow Air flow Nominal voltage Voltage range Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type m3/h CFM VDC VDC Bel(A) / Watts rpm °C Hours Hours RER 190-39/14/2 TDMLO 650 382 RER 190-39/14/2 TDMO 860 506 24 16...30 7,6 24 16...36 7,9 58 3 000 -20...+60 55 000 / 35 000 92 500 ➀ 110 3 900 -20...+65 52 500 / 30 000 87 500 ➁ RER 190-39/18/2 TDMLO* 650 382 48 36...57 7,6 56 3 000 -20...+65 55 000 / 30 000 92 500 ➀ RER 190-39/18/2 TDMO* 860 506 48 36...72 7,9 105 3 900 -20...+65 52 500 / 30 000 87 500 ➁ RER 190-39/18/2 TDO 970 571 48 36...72 8,3 148 4 400 -20...+65 40 000 / 22 500 67 500 ➂ * Auf Anfrage Subject to alternations Speed control range from 800 rpm at 7 % PWM up to nominal speed at > 90 % PWM. Standstill at 0 % PWM, standstill if control cable is interrupted. The air flow and noise level of the centrifugal fans without external housing depend on their individual installation conditions. The stated air flow and noise level were recorded under the following measurement parameters: Centrifugal fan mounted on a foundation plate 195 x 195 mm. Cover plate 195 x 195 mm, with an air inlet opening Ø 125,5 mm, arranged concentrically to the impeller. 2 6 +1 3,5 [in H O] [Pa] 58 + 0,1 72 +0,3 190 +0,3 M4 (4x) max. 8 deep 900 3 800 3 700 2 1,5 600 2 500 400 1 1,5 300 1 200 0,5 100 0 100 200 300 400 500 600 [CFM] 200 400 600 800 1000 [m3/h] 118 Inlet nozzles from p. 248 tin-plated 425 +10 39 69 +1 6,5 +1 119 Representatives Accessories AC centrifugal fans AC axial fans ACmaxx / GreenTech EC-Compact fans DC fans - specials DC centrifugal fans DC axial fans Information max. 930 m3/h DC centrifugal fans – RadiCal Ø 190 mm – Material: – Number of blades: – Direction of rotation: – Type of protection: – Insulation class: – Mounting position: – Condensate discharges: – Operation mode: – Bearings: Impeller: Plastic PA Rotor: Coated in black 7 Clockwise, seen on rotor IP 44, depending on installation and position "B" Any None Continuous operation (S1) Maintenance-free ball bearings Curve Nominal voltage Voltage range Air flow Speed / rpm Input power Current draw Sound power level Perm. amb. temp. Technical features and electrical connections Nominal data Type R3G 190 R3G 190 Subject to alternations Motor M3G 074-CF A M3G 074-CF B VDC VDC m3/h rpm W A dB(A) °C 24 16-28 880 4570 180 7,50 76 -25..+60 48 36-57 930 4800 192 4,00 76 -25..+60 p. 258 / J5) p. 258 / J5) Curve: B A n Ped rpm W I LWA A dB(A) A 1 4570 180 7,50 84 A 2 4525 188 7,83 79 A 3 4435 199 8,34 77 A 4 4520 191 7,96 81 B 1 4800 192 4,00 84 B 2 4690 212 4,41 80 B 3 4640 221 4,60 79 B 4 4740 205 4,28 81 120 Air performance measured as per: ISO 5801, Installation category A, with ebm-papst inlet nozzle without protection against accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted! For detailed information see http://www.ebmpapst.com/general conditions Information DC axial fans DC centrifugal fans – Technical features: – Cable exit: – Product conforming to standards: – Approvals: See electrical connections p. 258 Variabel EN 60950-1 GOST Mass centrifugal fans Centrifugal fans R3G 190-RN38 -01 R3G 190-RN99 -02 kg Inlet nozzle 1,9 09576-2-4013 1,9 09576-2-4013 Accessory part: Inlet nozzle 09576-2-4013 not included in the standard scope of delivery Depth of screw max. 12 - 14 mm DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Representatives Connecting line PVC AWG 16 4 x crimped core-end sleeves Guard grilles from p. 238 Inlet nozzles from p. 248 Electrical connections p. 258 121 max. 1210 m3/h DC centrifugal fans – RadiCal Ø 220 mm – Material: – Number of blades: – Direction of rotation: – Type of protection: – Insulation class: – Mounting position: – Condensate discharges: – Operation mode: – Bearings: Impeller: Plastic PA Rotor: Coated in black 7 Clockwise, seen on rotor IP 44, depending on installation and position "B" Any None Continuous operation (S1) Maintenance-free ball bearings Curve Nominal voltage Voltage range Air flow Speed / rpm Input power Current draw Sound power level Perm. amb. temp. Technical features and electrical connections Nominal data Type R3G 220 R3G 220 Subject to alternations Motor M3G 074-CF A M3G 074-CF B VDC VDC m3/h rpm W A dB(A) °C 24 16-28 1185 3480 162 6,75 73 -25...+60 48 36-57 1210 3510 160 3,40 73 -25...+60 p. 258 / J5) p. 258 / J5) Curve: B A n Ped rpm W I LWA A dB(A) A 1 3480 162 6,75 81 A 2 3420 171 7,11 77 A 3 3360 182 7,59 74 A 4 3455 168 6,97 79 B 1 3510 160 3,40 81 B 2 3450 168 3,50 77 B 3 3385 178 3,71 74 B 4 3460 167 3,47 79 122 Air performance measured as per: ISO 5801, Installation category A, with ebm-papst inlet nozzle without protection against accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted! For detailed information see http://www.ebmpapst.com/general conditions Information DC axial fans DC centrifugal fans – Technical features: – Cable exit: – Product conforming to standards: – Approvals: See electrical connections p. 258 Variabel EN 60950-1 GOST Mass centrifugal fans Centrifugal fans R3G 220-RN12 -01 R3G 220-RNB6 -02 kg Inlet nozzle 1,9 09609-2-4013 1,9 09609-2-4013 Accessory part: Inlet nozzle 09609-2-4013 not included in the standard scope of delivery Depth of screw max. 12 - 14 mm DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Representatives Connecting line PVC AWG 16 4 x crimped core-end sleeves Guard grilles from p. 238 Inlet nozzles from p. 248 Electrical connections p. 258 123 max. 1280 m3/h DC centrifugal fans Series RER 220 TD Ø 221 x 71 mm – Material: Impeller: GRP1) – Direction of air flow: Axial: Intake Centrifugal: Exhaust – Direction of rotation: Clockwise, seen on rotor – Connection: Via single wires AWG 18, 20 or AWG 22, TR 64, speed signal and control input AWG 22 – Highlights: 3-phase fan drive with very smooth running and high efficiency Backwards-curved impeller – Mass: 940 g 1) Fibreglass-reinforced plastic – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Multi-option control input - Protection against moisture - Protection against salt fog - Type of protection: IP 54 Air flow Air flow Nominal voltage Voltage range Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type m3/h CFM VDC VDC Bel(A) / Watts rpm °C Hours Hours RER 220-44/14/2 TDMO* 1090 641 24 16...36 7,7 82 3 000 -20...+55 75 000 / 52 500 127 500 ➀ RER 220-44/18/2 TDMO* 1090 641 48 36...72 7,7 80 3 000 -20...+55 75 000 / 52 500 127 500 ➀ RER 220-44/18/2 TDP 1280 753 48 36...72 8,0 140 3 500 -20...+55 55 000 / 40 000 92 500 ➁ * upon request Subject to alternations Speed control range from 800 rpm at 7 % PWM up to nominal speed at > 90 % PWM. Standstill at 0 % PWM, standstill if control cable is interrupted. The air flow and noise level of the centrifugal fans without external housing depend on their individual installation conditions. The stated air flow and noise level were recorded under the following measurement parameters: Centrifugal fan mounted on a foundation plate 230 x 230 mm. Cover plate 230 x 230 mm, with an air inlet opening Ø 155 mm, arranged concentrically to the impeller. [Pa] [in H O] 2 ø 58 + 0,1 M4 (4x) max. 8 deep ø 72+ 0,3 ø 220,9 + 0,5 0,25 0,5 0,75 1 1,25 1,5 1,75 2 2,25 2 600 500 1 400 300 200 100 0 100 200 300 400 500 600 700 [CFM] 200 400 600 800 1000 1200 [m3/h] 124 Inlet nozzles from p. 248 6 +1 425 +10 tin-plated 44,0 71+ 1 7,2 + 1,5 Information DC axial fans DC centrifugal fans max. 1600 m3/h DC centrifugal fans Series RER 225 TD Ø 225 x 99 mm – Material: Impeller: GRP1) – Direction of air flow: Axial: Intake Centrifugal: Exhaust – Direction of rotation: Clockwise, seen on rotor – Connection: Via single wires AWG 18, 20 or AWG 22, TR 64, speed signal and control input AWG 22 – Highlights: 3-phase fan drive with very smooth running and high efficiency Backwards-curved impeller – Mass: 1030 g 1) Fibreglass-reinforced plastic – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Multi-option control input - Protection against moisture - Protection against salt fog - Type of protection: IP 54 Air flow Air flow Nominal voltage Voltage range Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type m3/h CFM VDC VDC Bel(A) / Watts rpm °C Hours Hours NEW RER 225-63/18/2 TDMLO 1190 700 NEW RER 225-63/18/2 TDMO 1340 789 48 36...72 7,2 48 36...72 7,8 77 2 500 -20...+55 70 000 / 50 000 122 500 ➀ 108 2 800 -20...+55 55 000 / 40 000 92 500 ➁ NEW RER 225-63/18/2 TDO Subject to alternations 1600 941 48 36...72 8,1 163 3 300 -20...+55 52 500 / 37 500 87 500 ➂ Speed control range from 800 rpm at 7 % PWM up to nominal speed at > 90 % PWM. Standstill at 0 % PWM, standstill if control cable is interrupted. The air flow and noise level of the centrifugal fans without external housing depend on their individual installation conditions. The stated air flow and noise level were recorded under the following measurement parameters: Centrifugal fan mounted on a foundation plate 230 x 230 mm. Cover plate 230 x 230 mm, with an air inlet opening Ø 146 mm, arranged concentrically to the impeller. DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans 6 +1 425 +10 Accessories ø 58+ 0,1 M4 (4x) max. 8 deep ø 72+ 0,3 max. ø225 0,5 Inlet nozzles from p. 248 tin-plated 62,6 99 + 1 8,6 + 0,8 125 Representatives max. 1400 m3/h DC centrifugal fans – RadiCal Ø 225 mm – Material: – Number of blades: – Direction of rotation: – Type of protection: – Insulation class: – Mounting position: – Condensate discharges: – Operation mode: – Bearings: Impeller: Plastic PA Rotor: Coated in black 7 Clockwise, seen on rotor IP 44, depending on installation and position "B" Any None Continuous operation (S1) Maintenance-free ball bearings Curve Nominal voltage Voltage range Air flow Speed / rpm Input power Current draw Sound power level Perm. amb. temp. Technical features and electrical connections Nominal data Type R3G 225 R3G 225 Subject to alternations Motor M3G 074-CF A M3G 074-CF B VDC VDC m3/h rpm W A dB(A) °C 24 16-28 1275 3240 200 8,30 75 -25...+60 48 36-57 1400 3500 245 5,00 73 -25...+60 p. 258 / J5) p. 258 / J5) Curve: B A n Ped rpm W I LWA A dB(A) A 1 3240 200 8,30 81 A 2 3200 208 8,66 78 A 3 3185 213 8,88 74 A 4 3260 194 8,02 77 B 1 3500 245 5,00 83 B 2 3440 257 5,35 80 B 3 3435 260 5,43 76 B 4 3500 239 4,97 78 126 Air performance measured as per: ISO 5801, Installation category A, with ebm-papst inlet nozzle without protection against accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted! For detailed information see http://www.ebmpapst.com/general conditions Information DC axial fans DC centrifugal fans – Technical features: – Cable exit: – Product conforming to standards: – Approvals: See electrical connections p. 258 Variabel EN 60950-1 GOST Mass centrifugal fans Centrifugal fans R3G 225-RN28 -01 R3G 225-RN18 -02 kg Inlet nozzle 2,1 96358-2-4013 2,1 96358-2-4013 Accessory part: Inlet nozzle 96358-2-4013 not included in the standard scope of delivery Depth of screw max. 12 - 14 mm DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Representatives Connecting line PVC AWG 16 4 x crimped core-end sleeves Guard grilles from p. 238 Inlet nozzles from p. 248 Electrical connections p. 258 127 max. 1650 m3/h DC centrifugal fans – RadiCal Ø 250 mm – Material: – Number of blades: – Direction of rotation: – Type of protection: – Insulation class: – Mounting position: – Condensate discharges: – Operation mode: – Bearings: Impeller: Plastic PA Rotor: Coated in black 7 Clockwise, seen on rotor IP 44, depending on installation and position "B" Any None Continuous operation (S1) Maintenance-free ball bearings Curve Nominal voltage Voltage range Air flow Speed / rpm Input power Current draw Sound power level Perm. amb. temp. Technical features and electrical connections Nominal data Type R3G 250 R3G 250 Subject to alternations Motor M3G 074-CF A M3G 074-CF B VDC VDC m3/h rpm W A dB(A) °C 24 16-28 1650 3140 236 9,80 73 -25...+60 48 36-57 1640 3125 230 4,75 73 -25...+60 p. 258 / J5) p. 258 / J5) Curve: B A n Ped rpm W I LWA A dB(A) A 1 3140 236 9,80 81 A 2 3075 260 10,80 77 A 3 3035 276 11,45 75 A 4 3095 256 10,66 75 B 1 3125 230 4,75 81 B 2 3065 249 5,20 77 B 3 3025 266 5,55 75 B 4 3090 244 5,09 78 128 Air performance measured as per: ISO 5801, Installation category A, with ebm-papst inlet nozzle without protection against accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted! For detailed information see http://www.ebmpapst.com/general conditions Information DC axial fans DC centrifugal fans – Technical features: – Cable exit: – Product conforming to standards: – Approvals: See electrical connections p. 258 Variabel EN 60950-1 GOST Mass centrifugal fans Centrifugal fans R3G 250-RN46 -01 R3G 250-RNB5 -02 kg Inlet nozzle 2,1 96359-2-4013 2,1 96359-2-4013 Accessory part: Inlet nozzle 96359-2-4013 not included in the standard scope of delivery Depth of screw max. 12 - 14 mm DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Representatives Connecting line PVC AWG 16 4 x crimped core-end sleeves Guard grilles from p. 238 Inlet nozzles from p. 248 Electrical connections p. 258 129 max. 2210 m3/h DC centrifugal fans – RadiCal Ø 280 mm – Material: – Number of blades: – Direction of rotation: – Type of protection: – Insulation class: – Mounting position: – Condensate discharges: – Operation mode: – Bearings: Impeller: Plastic PP Rotor: Coated in black 6 Clockwise, seen on rotor IP 44, depending on installation and position "B" Any None Continuous operation (S1) Maintenance-free ball bearings Curve Nominal voltage Voltage range Air flow Speed / rpm Input power Current draw Sound power level Perm. amb. temp. Technical features and electrical connections Nominal data Type R3G 280 R3G 280 Subject to alternations Motor M3G 074-CF A M3G 074-CF B VDC VDC m3/h rpm W A dB(A) °C 24 16-28 2210 1930 148 6,10 67 -25...+60 48 36-57 2175 1910 140 2,90 67 -25...+60 p. 258 / J5) p. 258 / J5) Curve: A B n Ped rpm W I LWA A dB(A) A 1 1930 148 6,10 74 A 2 1870 162 6,76 67 A 3 1840 173 7,21 64 A 4 1905 153 6,36 68 B 1 1910 140 2,90 74 B 2 1845 158 3,30 67 B 3 1830 163 3,40 64 B 4 1900 141 2,93 68 130 Air performance measured as per: ISO 5801, Installation category A, with ebm-papst inlet nozzle without protection against accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted! For detailed information see http://www.ebmpapst.com/general conditions Information DC axial fans DC centrifugal fans – Technical features: – Cable exit: – Product conforming to standards: – Approvals: See electrical connections p. 258 Variabel EN 60950-1 GOST Mass centrifugal fans Centrifugal fans R3G 280-RN30 -01 R3G 280-RNB1 -02 kg Inlet nozzle 2,4 28000-2-4013 2,4 28000-2-4013 Accessory part: Inlet nozzle 28000-2-4013 not included in the standard scope of delivery Depth of screw max. 12 - 14 mm DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Representatives Connecting line PVC AWG 16 4 x crimped core-end sleeves Guard grilles from p. 238 Inlet nozzles from p. 248 Electrical connections p. 258 131 max. 2420 m3/h DC centrifugal fans – RadiCal Ø 310 mm – Material: – Number of blades: – Direction of rotation: – Type of protection: – Insulation class: – Mounting position: – Condensate discharges: – Operation mode: – Bearings: Impeller: Plastic PP Rotor: Coated in black 6 Clockwise, seen on rotor IP 44, depending on installation and position "B" Any None Continuous operation (S1) Maintenance-free ball bearings Curve Nominal voltage Voltage range Air flow Speed / rpm Input power Current draw Sound power level Perm. amb. temp. Technical features and electrical connections Nominal data Type R3G 310 R3G 310 Subject to alternations Motor M3G 074-CF A M3G 074-CF B VDC VDC m3/h RPM W A dB(A) °C 24 16-28 2380 1625 122 5,00 64 -25...+60 48 36-57 2420 1650 123 2,60 64 -25...+60 p. 258 / J5) p. 258 / J5) Curve: B A n Ped rpm W I LWA A dB(A) A 1 1625 122 5,00 70 A 2 1540 145 6,03 67 A 3 1520 152 6,34 63 A 4 1550 143 5,95 65 B 1 1650 123 2,60 70 B 2 1570 147 3,07 66 B 3 1545 156 3,26 63 B 4 1580 144 3,01 66 132 Air performance measured as per: ISO 5801, Installation category A, with ebm-papst inlet nozzle without protection against accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted! For detailed information see http://www.ebmpapst.com/general conditions Information DC axial fans DC centrifugal fans – Technical features: – Cable exit: – Product conforming to standards: – Approvals: See electrical connections p. 258 Variabel EN 60950-1 GOST Mass centrifugal fans Centrifugal fans R3G 310-RN99 -01 R3G 310-RN98 -02 kg Inlet nozzle 2,8 31000-2-4013 2,8 31000-2-4013 Accessory part: Inlet nozzle 31000-2-4013 not included in the standard scope of delivery Depth of screw max. 12 - 14 mm DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Representatives Connecting line PVC AWG 16 4 x crimped core-end sleeves Guard grilles from p. 238 Inlet nozzles from p. 248 Electrical connections p. 258 133 max. 155 m3/h DC-Querstromlüfter Series QG 030 201...413 x 50 x 48 mm – Material: Housing: Aluminium – Possible special versions: Housing side parts: Plastic (See chapter DC fans - specials) Impeller: Aluminium - Speed signal – Direction of air flow: See photo - Protection against moisture – Connection: Via single wires AWG 24, TR 64 – Highlights: Motor with ball bearing system Impeller retaining plate with plain bearing – Mass: 235 / 290 / 380 / 415 g Air flow Air flow Nominal voltage Voltage range Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type QG 030-148/12 QG 030-198/12 QG 030-303/12 QG 030-353/12 QG 030-148/14 QG 030-198/14 QG 030-303/14 QG 030-353/14 Subject to alternations m3/h CFM VDC VDC db(A) Bel(A) / 75 44 12 8...14 49 5,7 / 100 59 12 8...14 51 5,8 / 140 82 12 8...14 51 5,8 / 155 91 12 8...14 51 5,9 / 75 44 24 16...28 49 5,7 / 100 59 24 16...28 51 5,8 / 140 82 24 16...28 51 5,8 / 155 91 24 16...28 51 5,9 / Watts °C 6,2 -20...+60 8,0 -20...+60 8,7 -20...+60 9,6 -20...+60 6,2 -20...+60 8,0 -20...+60 8,7 -20...+60 9,6 -20...+60 Hours Hours 30 000 / 20 000 30 000 / 20 000 30 000 / 20 000 30 000 / 20 000 50 000 ➀ 50 000 ➁ 50 000 ➂ 50 000 ➃ 30 000 / 20 000 30 000 / 20 000 30 000 / 20 000 30 000 / 20 000 50 000 ➀ 50 000 ➁ 50 000 ➂ 50 000 ➃ The values for service life were recorded with the fan installed horizontally. Type Dimension: L L1 QG 030-148/ .. 203,4 +1,5 148 QG 030-198/ .. 260,4 +1,5 198 QG 030-303/ .. 365,4 +1,5 303 QG 030-353/ .. 415,4 +1,5 353 Mass 235 g 290 g 380 g 415 g Pa [in H O] 2 Tangential fans are only suitable for operation with high rate and low back pressure. 50 40 0,15 30 0,10 20 0,05 10 0 1 15 30 45 20 40 60 80 2 34 60 75 CFM 100 120 m³/h 134 Cut-out for square nut M3 DIN 562, flat (6x) 135 Representatives Accessories AC centrifugal fans AC axial fans ACmaxx / GreenTech EC-Compact fans DC fans - specials DC centrifugal fans DC axial fans Information 95 max. m3/h DC centrifugal fans and blowers Ø 85 mm – Material: – Direction of rotation: – Type of protection: – Insulation class: – Mounting position: – Condensate discharges: – Operation mode: – Bearings: Housing: Die-cast aluminium Impeller: Hot-dip galvanised sheet steel Rotor: Galvanised Clockwise, seen on rotor IP 22 "B" Any None Continuous operation (S1) Maintenance-free ball bearings Curve Nominal voltage Voltage range Air flow Speed / rpm Input power Current draw Sound power level Min. back-pressure Perm. amb. temp. Technical features and electrical connections Nominal data Type *1G 085 *1G 085 Subject to alternations Motor M1G 045-BE A M1G 045-BE A VDC VDC m3/h rpm 24 16-28 48 36-57 95 2850 95 2850 W A dB(A) Pa °C 14 0,64 57 14 0,32 57 0 -25...+60 0 -25...+60 p. 255 / G) p. 255 / G) Curve: UN = nominal voltage (24 V /48 V) UR = overvoltage (28 V / 57 V) n Ped LpA ηtL rpm W dB(A) % A 1’ 3180 19 59 — A 2’ 3300 16 57 28 A 3’ 3500 15 57 32 A 4’ 3800 12 57 37 A 1 2850 14 57 — A 2 3000 12 55 28 A 3 3180 11 55 32 A 4 3400 9 54 37 A 5 1890 5 46 — A 6 1970 4 44 25 A 7 2070 4 44 30 A 8 2170 3 42 33 136 Air performance measured as per: ISO 5801, Installation category A, with ebm-papst inlet nozzle without protection against accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted! For detailed information see http://www.ebmpapst.com/general conditions Information DC axial fans DC centrifugal fans DC fans - specials – Technical features: – Cable exit: – Protection class: – Product conforming to standards: – Approvals: See electrical connections p. 255 Axial I EN 60950-1 A (48 VDC) CCC Mass centrifugal fans Mass centrifugal blowers Centrifugal fans R1G 085-AB05 -01 R1G 085-AB07 -01 kg Centrifugal blowers with flange kg 0,5 G1G 085-AB05 -01 0,8 0,5 G1G 085-AB07 -01 0,8 Depth of screw max. 4 mm Brass lead tips ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Representatives Guard grilles from p. 238 Inlet nozzles from p. 248 Electrical connections p. 255 137 95 max. m3/h DC centrifugal fans and blowers Ø 97 mm – Material: – Direction of rotation: – Type of protection: – Insulation class: – Mounting position: – Condensate discharges: – Operation mode: – Bearings: Housing: Hot-dip galvanised sheet steel Impeller: Hot-dip galvanised sheet steel Rotor: Galvanised Clockwise, seen on rotor IP 22 "B" Any None Continuous operation (S1) Maintenance-free ball bearings Curve Nominal voltage Voltage range Air flow Speed / rpm Input power Current draw Sound power level Min. back-pressure Perm. amb. temp. Technical features and electrical connections Nominal data Type *1G 097 *1G 097 Subject to alternations Motor M1G 045-BE A M1G 045-BE A VDC VDC m3/h rpm 24 16-28 48 36-57 95 2650 95 2650 W A dB(A) Pa °C 16 0,75 59 16 0,38 59 0 -25...+60 0 -25...+60 p. 255 / G) p. 255 / G) Curve: UN = nominal voltage (24 V /48 V) UR = overvoltage (28 V / 57 V) n Ped LpA ηtL rpm W dB(A) % A 1’ 2920 22 62 — A 2’ 3030 21 61 41 A 3’ 3300 17 59 48 A 4’ 3700 13 58 48 A 1 2650 16 59 — A 2 2730 15 58 41 A 3 2960 13 56 48 A 4 3290 10 55 48 A 5 1615 4 45 — A 6 1650 4 45 38 A 7 1745 4 43 46 A 8 1880 3 42 47 138 Air performance measured as per: ISO 5801, Installation category A, with ebm-papst inlet nozzle without protection against accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted! For detailed information see http://www.ebmpapst.com/general conditions Information DC axial fans DC centrifugal fans DC fans - specials – Technical features: – Cable exit: – Protection class: – Product conforming to standards: – Approvals: See electrical connections p. 255 Axial I EN 60950-1 A (48 VDC) CCC Mass centrifugal fans Mass centrifugal blowers Centrifugal fans R1G 097-AA05 -01 R1G 097-AA07 -01 kg Centrifugal blowers with flange kg 0,5 G1G 097-AA05 -01 0,8 0,5 G1G 097-AA07 -01 0,8 Depth of screw max. 4 mm Brass lead tips ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Representatives Guard grilles from p. 238 Inlet nozzles from p. 248 Electrical connections p. 255 139 max. 200 m3/h DC centrifugal fans and blowers Ø 108 mm – Material: – Direction of rotation: – Type of protection: – Insulation class: – Mounting position: – Condensate discharges: – Operation mode: – Bearings: Housing: Die-cast aluminium Impeller: Hot-dip galvanised sheet steel Rotor: Galvanised Clockwise, seen on rotor IP 22 "B" Any None Continuous operation (S1) Maintenance-free ball bearings Curve Nominal voltage Voltage range Air flow Speed / rpm Input power Current draw Sound power level Min. back-pressure Perm. amb. temp. Technical features and electrical connections Nominal data Type *1G 108 *1G 108 Subject to alternations Motor M1G 055-BD A M1G 055-BD .A VDC VDC m3/h rpm 24 16-28 200 3000 48 36-57 200 3000 W A dB(A) Pa °C 42 2,00 65 42 1,00 65 0 -25...+60 0 -25...+60 p. 255 / G) p. 255 / G) Curve: UN = nominal voltage (24 V /48 V) UR = overvoltage (28 V / 57 V) n Ped LpA ηtL rpm W dB(A) % A 1’ 3230 55 67 — A 2’ 3410 52 66 33 A 3’ 3800 43 65 41 A 4’ 4100 35 64 33 A 1 3000 42 65 — A 2 3140 40 64 33 A 3 3420 32 63 41 A 4 3690 26 63 33 A 5 2300 20 61 — A 6 2380 17 58 33 A 7 2550 14 55 41 A 8 2720 11 55 33 140 Air performance measured as per: ISO 5801, Installation category A, with ebm-papst inlet nozzle without protection against accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted! For detailed information see http://www.ebmpapst.com/general conditions Information DC axial fans DC centrifugal fans DC fans - specials – Technical features: – EMC: – Cable exit: – Protection class: – Product conforming to standards: – Approvals: See electrical connections p. 255 Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Axial I EN 60950-1 A (24 VDC) UL, CSA, A (48 VDC) CCC Mass centrifugal fans Mass centrifugal blowers Centrifugal fans R1G 108-AB17 -02 R1G 108-AB41 -02 kg Centrifugal blowers with flange kg 0,7 G1G 108-AB17 -02 1,4 0,7 G1G 108-AB41 -02 1,4 Depth of screw max. 6 mm Brass lead tips ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Representatives Guard grilles from p. 238 Inlet nozzles from p. 248 Electrical connections p. 255 141 max. 255 m3/h DC centrifugal fans and blowers Ø 120 mm – Material: – Direction of rotation: – Type of protection: – Insulation class: – Mounting position: – Condensate discharges: – Operation mode: – Bearings: Housing: Die-cast aluminium Impeller: Hot-dip galvanised sheet steel Rotor: Galvanised Clockwise, seen on rotor IP 22 "B" Any None Continuous operation (S1) Maintenance-free ball bearings Curve Nominal voltage Voltage range Air flow Speed / rpm Input power Current draw Sound power level Min. back-pressure Perm. amb. temp. Technical features and electrical connections Nominal data Type *1G 120 *1G 120 Subject to alternations Motor M1G 055-BD A M1G 055-BD A VDC VDC m3/h rpm 24 16-28 255 2200 48 36-57 255 2200 W A dB(A) Pa °C 40 1,90 62 40 0,95 62 0 -25...+60 0 -25...+60 p. 255 / G) p. 255 / G) Curve: UN = nominal voltage (24 V /48 V) UR = overvoltage (28 V / 57 V) n Ped LpA ηtL rpm W dB(A) % A 1’ 2410 50 63 — A 2’ 2620 47 62 58 A 3’ 2870 44 61 60 A 4’ 3200 36 62 55 A 1 2200 40 62 — A 2 2410 36 60 59 A 3 2600 32 58 62 A 4 2880 25 58 55 A 5 1870 24 55 — A 6 1990 21 54 58 A 7 2100 18 53 61 A 8 2310 14 54 54 142 Air performance measured as per: ISO 5801, Installation category A, with ebm-papst inlet nozzle without protection against accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted! For detailed information see http://www.ebmpapst.com/general conditions Information DC axial fans DC centrifugal fans DC fans - specials – Technical features: – EMC: – Cable exit: – Protection class: – Product conforming to standards: – Approvals: See electrical connections p. 255 Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Axial I EN 60950-1 A (24 VDC) UL, CSA, A (48 VDC) CCC Mass centrifugal fans Mass centrifugal blowers Centrifugal fans R1G 120-AB67 -02 R1G 120-AB71 -02 kg Centrifugal blowers with flange kg 0,8 G1G 120-AB67 -02 1,6 0,8 G1G 120-AB71 -02 1,6 Depth of screw max. 6 mm Brass lead tips ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Representatives Guard grilles from p. 238 Inlet nozzles from p. 248 Electrical connections p. 255 143 max. 225 m3/h DC centrifugal fans and blowers Ø 133 mm – Material: – Direction of rotation: – Type of protection: – Insulation class: – Mounting position: – Condensate discharges: – Operation mode: – Bearings: Housing: Die-cast aluminium Impeller: Hot-dip galvanised sheet steel Rotor: Galvanised Clockwise, seen on rotor IP 22 "B" Any None Continuous operation (S1) Maintenance-free ball bearings Curve Nominal voltage Voltage range Air flow Speed / rpm Input power Current draw Sound power level Min. back-pressure Perm. amb. temp. Technical features and electrical connections Nominal data Type *1G 133 *1G 133 Subject to alternations Motor M1G 055-BD A M1G 055-BD A VDC VDC m3/h rpm 24 16-28 225 2000 48 36-57 225 2000 W A dB(A) Pa °C 40 2,20 64 40 1,10 64 0 -25...+60 0 -25...+60 p. 255 / G) p. 255 / G) Curve: UN = nominal voltage (24 V /48 V) UR = overvoltage (28 V / 57 V) n Ped LpA ηtL rpm W dB(A) % A 1’ 2170 57 66 — A 2’ 2410 51 66 47 A 3’ 2750 44 64 49 A 4’ 3200 36 66 32 A 1 2000 45 64 — A 2 2230 40 64 49 A 3 2540 35 62 51 A 4 2920 27 63 33 A 5 1750 28 60 — A 6 1910 24 59 50 A 7 2120 20 58 53 A 8 2370 15 59 35 144 Air performance measured as per: ISO 5801, Installation category A, with ebm-papst inlet nozzle without protection against accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted! For detailed information see http://www.ebmpapst.com/general conditions Information DC axial fans DC centrifugal fans DC fans - specials – Technical features: – EMC: – Cable exit: – Protection class: – Product conforming to standards: – Approvals: See electrical connections p. 255 Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Lateral I EN 60950-1 A (24 VDC) UL, CSA, A (48 VDC) CCC Mass centrifugal fans Mass centrifugal blowers Centrifugal fans R1G 133-AE19 -02 R1G 133-AE03 -02 kg Centrifugal blowers with flange kg 0,7 G1G 133-DE19 -02 1,3 0,7 G1G 133-DE03 -02 1,3 Depth of screw max. 6 mm Brass lead tips ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Representatives Guard grilles from p. 238 Inlet nozzles from p. 248 Electrical connections p. 255 145 max. 410 m3/h DC centrifugal fans and blowers Ø 140 mm – Material: – Direction of rotation: – Type of protection: – Insulation class: – Mounting position: – Condensate discharges: – Operation mode: – Bearings: Housing: Die-cast aluminium Impeller: Hot-dip galvanised sheet steel Rotor: Galvanised Clockwise, seen on rotor IP 22 "B" Any None Continuous operation (S1) Maintenance-free ball bearings Curve Nominal voltage Voltage range Air flow Speed / rpm Input power Current draw Sound power level Min. back-pressure Perm. amb. temp. Technical features and electrical connections Nominal data Type *1G 140 *1G 140 Subject to alternations Motor M1G 055-BD A M1G 055-BD A VDC VDC m3/h rpm 24 16-28 400 1750 48 36-57 410 1750 W A dB(A) Pa °C 54 2,50 63 54 1,30 63 0 -25...+60 0 -25...+60 p. 255 / G) p. 255 / G) Curve: UN = nominal voltage (24 V /48 V) UR = overvoltage (28 V / 57 V) n Ped LpA ηtL rpm W dB(A) % A 1’ 1850 65 64 — A 2’ 2020 61 61 50 A 3’ 2200 57 59 54 A 4’ 2550 43 60 40 A 1 1750 54 63 — A 2 1900 50 59 51 A 3 2030 45 58 54 A 4 2310 32 58 40 A 5 1500 34 60 — A 6 1580 29 56 50 A 7 1670 25 54 53 A 8 1880 19 53 41 146 Air performance measured as per: ISO 5801, Installation category A, with ebm-papst inlet nozzle without protection against accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted! For detailed information see http://www.ebmpapst.com/general conditions Information DC axial fans DC centrifugal fans DC fans - specials – Technical features: – EMC: – Cable exit: – Protection class: – Product conforming to standards: – Approvals: See electrical connections p. 255 Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Axial I EN 60950-1 A (48 VDC) CCC Mass centrifugal fans Mass centrifugal blowers Centrifugal fans R1G 140-AV17 -02 R1G 140-AV21 -02 kg Centrifugal blowers with flange kg 1,0 G1G 140-AV17 -02 2,3 1,0 G1G 140-AV21 -02 2,3 Depth of screw max. 6 mm Brass lead tips ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Representatives Guard grilles from p. 238 Inlet nozzles from p. 248 Electrical connections p. 255 147 max. 470 m3/h DC centrifugal fans and blowers Ø 146 mm – Material: – Direction of rotation: – Type of protection: – Insulation class: – Mounting position: – Condensate discharges: – Operation mode: – Bearings: Housing: Die-cast aluminium Impeller: Hot-dip galvanised sheet steel Rotor: Galvanised Clockwise, seen on rotor IP 42 "B" Any None Continuous operation (S1) Maintenance-free ball bearings Curve Nominal voltage Voltage range Air flow Speed / rpm Input power Current draw Sound power level Min. back-pressure Perm. amb. temp. Technical features and electrical connections Nominal data Type *1G 146 *1G 146 Subject to alternations Motor M1G 074-BF A M1G 074-BF A VDC VDC m3/h rpm W A dB(A) Pa °C 24 16-28 470 2200 100 5,00 68 48 36-57 465 2150 100 2,60 67 0 -25...+60 0 -25...+60 p. 255 / G) p. 255 / G) Curve: UN = nominal voltage (24 V /48 V) UR = overvoltage (28 V / 57 V) n Ped LpA ηtL rpm W dB(A) % A 1’ 2400 140 70 — A 2’ 2650 130 67 45 A 3’ 3000 110 66 49 A 4’ 3300 100 67 45 A 1 2200 100 68 — A 2 2445 90 65 46 A 3 2750 84 64 49 A 4 3025 77 65 45 A 5 1890 68 63 — A 6 2075 57 60 46 A 7 2250 48 61 49 A 8 2335 41 61 45 A 9 1520 37 59 — A 10 1670 32 55 46 A 11 1815 27 55 49 A 12 1920 23 55 45 148 Air performance measured as per: ISO 5801, Installation category A, with ebm-papst inlet nozzle without protection against accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted! For detailed information see http://www.ebmpapst.com/general conditions Information DC axial fans DC centrifugal fans DC fans - specials – Technical features: – EMC: – Cable exit: – Protection class: – Product conforming to standards: – Approvals: See electrical connections p. 255 Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Axial I EN 60950-1 UL, CSA, CCC (only centrifugal blowers) Mass centrifugal fans Mass centrifugal blowers Centrifugal fans R1G 146-AA07 -52 R1G 146-AA11 -52 kg Centrifugal blowers with flange kg 1,4 G1G 146-BA07 -52 2,8 1,4 G1G 146-BA11 -52 2,8 Depth of screw max. 6 mm Brass lead tips ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Representatives Guard grilles from p. 238 Inlet nozzles from p. 248 Electrical connections p. 255 149 max. 505 m3/h DC centrifugal fans and blowers Ø 160 mm – Material: – Direction of rotation: – Type of protection: – Insulation class: – Mounting position: – Condensate discharges: – Operation mode: – Bearings: Housing: Die-cast aluminium Impeller: Hot-dip galvanised sheet steel Rotor: Galvanised Clockwise, seen on rotor IP 42 "B" Any None Continuous operation (S1) Maintenance-free ball bearings Curve Nominal voltage Voltage range Air flow Speed / rpm Input power Current draw Sound power level Min. back-pressure Perm. amb. temp. Technical features and electrical connections Nominal data Type *1G 160 *1G 160 Subject to alternations Motor M1G 074-BF A M1G 074-BF A VDC VDC m3/h rpm W A dB(A) Pa °C 24 16-28 505 1750 105 5,80 67 48 36-57 505 1750 105 2,90 67 0 -25...+60 0 -25...+60 p. 255 / G) p. 255 / G) Curve: UN = nominal voltage (24 V /48 V) UR = overvoltage (28 V / 57 V) n Ped LpA ηtL rpm W dB(A) % A 1’ 1890 134 68 — A 2’ 2200 118 67 52 A 3’ 2500 110 67 57 A 4’ 2900 102 69 52 A 1 1750 105 67 — A 2 2030 95 66 52 A 3 2270 90 65 57 A 4 2550 81 67 44 A 5 1580 72 62 — A 6 1810 66 62 52 A 7 2000 58 62 57 A 8 2200 48 63 54 150 Air performance measured as per: ISO 5801, Installation category A, with ebm-papst inlet nozzle without protection against accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted! For detailed information see http://www.ebmpapst.com/general conditions Information DC axial fans DC centrifugal fans DC fans - specials – Technical features: – EMC: – Cable exit: – Protection class: – Product conforming to standards: – Approvals: See electrical connections p. 255 Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Axial I EN 60950-1 UL, CSA Mass centrifugal fans Mass centrifugal blowers Centrifugal fans R1G 160-AH29 -52 R1G 160-AH39 -52 kg Centrifugal blowers with flange kg 1,4 G1G 160-BH29 -52 2,8 1,4 G1G 160-BH39 -52 2,8 Depth of screw max. 6 mm Brass lead tips ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Representatives Guard grilles from p. 238 Inlet nozzles from p. 248 Electrical connections p. 255 151 max. 700 m3/h DC Centrifugal blowers Ø 133 mm – Material: – Direction of rotation: – Type of protection: – Insulation class: – Mounting position: – Condensate discharges: – Operation mode: – Design: – Bearings: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Coated in black Clockwise, seen on rotor IP 42 "B" Any None Continuous operation (S1) Standard external-rotor motor anti-vibration mounted on both sides Maintenance-free ball bearings Curve Nominal voltage Voltage range Air flow Speed / rpm Input power Current draw Sound power level Min. back-pressure Perm. amb. temp. Technical features and electrical connections Nominal data Type D1G 133 D1G 133 Subject to alternations Motor M1G 074-BF A M1G 074-BF A VDC VDC m3/h rpm W A dB(A) Pa °C 24 16-28 700 1780 105 5,60 62 48 36-57 700 1780 105 2,80 62 50 -25...+60 50 -25...+60 p. 255 / G) p. 255 / G) Curve: UN = nominal voltage (24 V /48 V) UR = overvoltage (28 V / 57 V) n Ped LpA ηtL rpm W dB(A) % A 1’ — — — — A 2’ 2050 121 63 49 A 3’ 2490 106 62 41 A 4’ 2820 100 62 37 A 1 1780 105 62 — A 2 1900 97 61 49 A 3 2310 86 59 41 A 4 2630 80 60 37 A 5 1500 73 59 — A 6 1720 67 57 49 A 7 2020 58 56 41 A 8 2230 49 56 37 152 Air performance measured as per: ISO 5801, Installation category A, with ebm-papst inlet nozzle without protection against accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted! For detailed information see http://www.ebmpapst.com/general conditions Information DC axial fans DC centrifugal fans – Technical features: – EMC: – Cable exit: – Protection class: – Product conforming to standards: – Approvals: See electrical connections p. 255 Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Variabel I EN 60950-1 UL, CSA; A (48 VDC) auch CCC Mass centrifugal blowers Centrifugal blowers without flange kg D1G 133-AB29 -52 3,3 D1G 133-AB39 -52 3,3 DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Brass lead tips Guard grilles from p. 238 Inlet nozzles from p. 248 Electrical connections p. 255 153 Representatives max. 1020 m3/h DC Centrifugal blowers Ø 133 mm – Material: – Direction of rotation: – Type of protection: – Insulation class: – Mounting position: – Condensate discharges: – Operation mode: – Design: – Bearings: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Coated in black Clockwise, seen on rotor IP 42 "B" Any None Continuous operation (S1) Standard external-rotor motor anti-vibration mounted on both sides Maintenance-free ball bearings Curve Nominal voltage Voltage range Air flow Speed / rpm Input power Current draw Sound power level Min. back-pressure Perm. amb. temp. Technical features and electrical connections Nominal data Type D1G 133 D1G 133 Subject to alternations Motor M1G 074-BF A M1G 074-BF A VDC VDC m3/h rpm W A dB(A) Pa °C 24 16-28 1020 1580 118 6,00 64 48 36-57 1020 1580 118 3,00 64 0 -25...+60 0 -25...+60 p. 255 / G) p. 255 / G) Curve: UN = nominal voltage (24 V /48 V) UR = overvoltage (28 V / 57 V) n Ped LpA ηtL rpm W dB(A) % A 1’ 1700 145 65 — A 2’ 1930 133 62 38 A 3’ 2290 122 59 41 A 4’ 2700 99 61 32 A 1 1580 118 64 — A 2 1790 107 61 38 A 3 2100 95 57 41 A 4 2410 73 58 32 A 5 1400 78 60 — A 6 1580 70 56 38 A 7 1760 56 53 41 A 8 2000 44 53 32 154 Air performance measured as per: ISO 5801, Installation category A, with ebm-papst inlet nozzle without protection against accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted! For detailed information see http://www.ebmpapst.com/general conditions Information DC axial fans DC centrifugal fans – Technical features: – EMC: – Cable exit: – Protection class: – Product conforming to standards: – Approvals: See electrical connections p. 255 Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Variabel I EN 60950-1 UL, CSA Mass centrifugal blowers Centrifugal blowers without flange kg D1G 133-DC13 -52 3,4 D1G 133-DC17 -52 3,4 DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Brass lead tips Guard grilles from p. 238 Inlet nozzles from p. 248 Electrical connections p. 255 155 Representatives max. 1000 m3/h DC Centrifugal blowers Ø 146 mm – Material: – Direction of rotation: – Type of protection: – Insulation class: – Mounting position: – Condensate discharges: – Operation mode: – Design: – Bearings: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Coated in black Clockwise, seen on rotor IP 42 "B" Any None Continuous operation (S1) Standard external-rotor motor anti-vibration mounted on both sides Maintenance-free ball bearings Curve Nominal voltage Voltage range Air flow Speed / rpm Input power Current draw Sound power level Min. back-pressure Perm. amb. temp. Technical features and electrical connections Nominal data Type D1G 146 D1G 146 Subject to alternations Motor M1G 074-CF A M1G 074-CF A VDC VDC m3/h rpm W A dB(A) Pa °C 24 16-28 1000 1350 105 5,10 61 48 36-57 1000 1350 105 2,60 61 0 -25...+60 0 -25...+60 p. 255 / G) p. 255 / G) Curve: UN = nominal voltage (24 V /48 V) UR = overvoltage (28 V / 57 V) n Ped LpA ηtL rpm W dB(A) % A 1’ 1460 129 63 — A 2’ 1680 119 60 53 A 3’ 1890 111 58 61 A 4’ 2240 95 59 55 A 1 1350 105 61 — A 2 1570 95 58 53 A 3 1750 88 56 61 A 4 2010 70 57 55 A 5 1210 70 56 — A 6 1360 60 54 53 A 7 1460 53 52 61 A 8 1670 42 51 55 156 Air performance measured as per: ISO 5801, Installation category A, with ebm-papst inlet nozzle without protection against accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted! For detailed information see http://www.ebmpapst.com/general conditions Information DC axial fans DC centrifugal fans – Technical features: – EMC: – Cable exit: – Protection class: – Product conforming to standards: – Approvals: See electrical connections p. 255 Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Variabel I EN 60950-1 UL, CSA Mass centrifugal blowers Centrifugal blowers without flange kg D1G 146-AA19 -52 3,5 D1G 146-AA33 -52 3,5 DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Brass lead tips Guard grilles from p. 238 Inlet nozzles from p. 248 Electrical connections p. 255 157 Representatives max. 980 m3/h DC Centrifugal blowers Ø 160 mm – Material: – Direction of rotation: – Type of protection: – Insulation class: – Mounting position: – Condensate discharges: – Operation mode: – Design: – Bearings: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Coated in black Clockwise, seen on rotor IP 42 "B" Any None Continuous operation (S1) Standard external-rotor motor anti-vibration mounted on both sides Maintenance-free ball bearings Curve Nominal voltage Voltage range Air flow Speed / rpm Input power Current draw Sound power level Min. back-pressure Perm. amb. temp. Technical features and electrical connections Nominal data Type D1G 160 D1G 160 Subject to alternations Motor M1G 074-CF A M1G 074-CF A VDC VDC m3/h rpm W A dB(A) Pa °C 24 16-28 980 1250 112 5,60 60 48 36-57 980 1250 112 2,90 60 0 -25...+60 0 -25...+60 p. 255 / G) p. 255 / G) Curve: UN = nominal voltage (24 V /48 V) UR = overvoltage (28 V / 57 V) n Ped LpA ηtL rpm W dB(A) % A 1’ 1330 142 63 — A 2’ 1520 128 61 64 A 3’ 1790 115 59 66 A 4’ 2090 105 60 60 A 1 1250 112 60 — A 2 1420 102 59 64 A 3 1660 92 58 66 A 4 1900 80 58 60 A 5 1100 75 58 — A 6 1250 69 56 64 A 7 1420 58 54 66 A 8 1580 47 53 60 158 Air performance measured as per: ISO 5801, Installation category A, with ebm-papst inlet nozzle without protection against accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted! For detailed information see http://www.ebmpapst.com/general conditions Information DC axial fans DC centrifugal fans DC fans - specials – Technical features: – EMC: – Cable exit: – Protection class: – Product conforming to standards: – Approvals: See electrical connections p. 255 Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Variabel I EN 60950-1 UL, CSA Mass centrifugal blowers Centrifugal blowers without flange kg D1G 160-DA19 -52 3,6 D1G 160-DA33 -52 3,6 Brass lead tips ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Representatives Guard grilles from p. 238 Inlet nozzles from p. 248 Electrical connections p. 255 159 160 Information DC axial fans DC fans - specials Speed signal 164 Alarm signal 168 Vario-Pro / Speed setting / Control input 173 Protection against ambient influences, Protection class IP 54 / IP 68 177 DC centrifugal fans DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Representatives 161 DC fans - specials Technical information Cooling capacity and efficiency Greater power density, increasing miniaturisation and extreme electronic component density are posing increased demands on the cooling capacity and efficiency of fans. The intelligent and space-saving integration of the fan in the device configuration is therefore of major importance: • Tailor-made cooling adapted to the situation as and when required. • Programmable cooling by defining speed profiles. • Transparency of function thanks to complete, interactive monitoring in all operating conditions. 1. Speed adjustment via temperature sensor ebm-papst answers with a complete range of DC fans with temperaturecontrolled speed adjustment via a temperature sensor, available in a variety of standard dimensions. Installation is very simple. The control electronics receive thermal information for the speed adjustment continuously and without losses, either externally via a freely designed and positionable strand, or internally directly in the fan hub in the air flow. A range of temperature sensors can be found on page 174. Standard fans in electronics cooling have proven themselves millions of times. With a constant speed and a correspondingly high noise level, they continuously provide the air flow needed for extreme cases. These extreme situations, however, occur extremely rarely, if at all, during the operating period. An intelligent fan is needed, which adapts automatically to the currently required level of cooling. ebm-papst provides intelligent cooling concepts which are optimally adapted to requirements. For example: 2. DC fans with separate control input Open or closed-loop speed control is also possible with DC fans that have a separate control input. A variation in speed can thus be implemented via a control voltage or a pulse-width modulated signal. These possibilities are used primarily in devices that have appropriate standard interfaces and thus require a load-dependent variation of the fans. 162 Information DC axial fans DC centrifugal fans DC fans - specials DC fans - specials Technical information 3. Speed signal DC fans with speed signal. The integrated „electronic tachometer“ continuously provides an actual speed signal for external evaluation. The user is informed at all times of the current fan speed via an extremely simple signal evaluation on the customer side. The speed signal is via a separate lead. 4. Alarm signal For applications which require monitored fan operation with alarm signal, ebm-papst has numerous alarm signal versions, either a static, pre-processed or interface-compatible high or low continuous signal depending on the type of fan. 5. Turbo drives Fans with three-phase EC drives and microprocessor-controlled motor electronics. These three-phase motors whose torque is virtually nonreliant on the rotor position are used for extremely high running smoothness. The speed of these fans can be controlled over a very wide range with PWM, analogue voltage or temperature. Optionally, the fans can be supplied with reversible direction of rotation and active brake operation. 6. Vario-Pro fans This high-end fan concept by ebmpapst with programmed intelligence and customer-specific integrated functions makes your electronics cooling even more versatile and competitive. Vario-Pro ensures a fresh economic breeze for all demanding cooling tasks – e.g. where greater reliability, more flexibility and intelligent function features such as alarm function, speed control etc. are required. The successful concept of Vario-Pro is: Tailor-made software instead of fixed hardware, because programmed software modules for motor control and application intelligence are responsible for the work that analogue components were responsible for in the past. This central control unit of the Vario-Pro comprises a microcontroller and an EEPROM, on which all characteristics are stored. 7. Protection against environmental influences Some applications place particular demands on the fans resistance to ambient influences, such as dust, moisture, water and salt. ebm-papst offer solutions for adapting fans to these ambient conditions. ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Representatives 163 Speed signal /2 – Speed-proportional rectangular pulse for external speed monitoring of fan motor – 2, 3 or 6 pulses per revolution – Open collector signal output – Extremely wide operating voltage range – Easy adaptation to user interface – Connection via separate lead – The sensor signal also serves as a major comparison variable for setting and maintaining the setpoint speed for interactive or controlled cooling with one or several interconnected fans. Speed signal US Low Condition: Isink Speed signal US High Condition: Isource Sensor operating voltage UBS max. Perm. sink current Isink max. Pulses per revolution Fan description Basic type Electrical connection Ra All voltages measured to ground. External load resistor Ra / US / UBS required. Alle TD Lüfter. Bsp.: 6400 TD 164 Signal data Type VDC mA 250 ≤ 0,4 2 400 F ≤ 0,4 1 400 ≤ 0,4 1 420 J ≤ 0,4 2 500 F ≤ 0,4 1 600 F ≤ 0,4 1 620 ≤ 0,4 2 630 U ≤ 0,4 2 600 N ≤ 0,4 2 600 J ≤ 0,4 2 700 F ≤ 0,4 2 8450 ≤ 0,4 2 8400 N ≤ 0,4 2 8400 N VARIOFAN ≤ 0,4 2 8300 ≤ 0,4 2 8200 J ≤ 0,4 2 3400 N ≤ 0,4 2 3400 N VARIOFAN ≤ 0,4 2 3300 ≤ 0,4 2 3300 N ≤ 0,4 2 3212 J / 3214 J ≤ 0,4 2 3218 J ≤ 0,4 2 3250 J ≤ 0,4 2 4412 F / 4414 F ≤ 0,4 2 4418 F ≤ 0,4 2 4400 FN ≤ 0,4 2 4312 / 4314 ≤ 0,4 2 4318 ≤ 0,4 2 4312 / 4314 VARIOFAN ≤ 0,4 2 4318 VARIOFAN ≤ 0,4 2 4400 ≤ 0,4 2 4100 N ≤ 0,4 2 4100 NHH...NH6 ≤ 0,4 2 4100 NH7...NH8 ≤ 0,4 2 DV 4100 Subject to alternations ≤ 0,4 2 VDC ≤ 30 ≤ 30 ≤ 30 ≤ 15 ≤ 30 ≤ 30 ≤ 30 ≤ 30 ≤ 28 ≤ 30 ≤ 30 ≤ 28 ≤ 28 ≤ 30 ≤ 30 ≤ 30 ≤ 28 ≤ 30 ≤ 30 ≤ 30 ≤ 30 ≤ 60 ≤ 60 ≤ 30 ≤ 60 ≤ 30 ≤ 30 ≤ 60 ≤ 30 ≤ 60 ≤ 30 ≤ 30 ≤ 60 ≤ 60 ≤ 30 mA VDC 0 30 0 30 0 30 0 15 0 30 0 30 0 30 0 30 0 28 0 30 0 30 0 28 0 28 0 30 0 30 0 30 0 28 0 30 0 30 0 30 0 30 0 60 0 60 0 30 0 60 0 30 0 30 0 60 0 30 0 60 0 30 0 30 0 60 0 60 0 30 mA 2 2 2 4 2 2 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 10 20 4 Page 2 31 2 32 2 33 2 34 2 35 2 36 2 37 2 38 2 39 2 41 2 42 2 43 2 44 2 45 2 46 2 47 2 48 2 49 2 50 2 51 2 52 2 52 3 53 2 54 2 54 2 55 2 56 2 56 2 57 2 57 2 58/59 2 60 2 61 3 62 2 63 Information Available on request: – Electrically isolated sensor and signal circuit – Varying voltage potentials for power and logic circuit DC axial fans DC centrifugal fans Speed signal US Low Condition: Isink Speed signal US High Condition: Isource Sensor operating voltage UBS max. Perm. sink current Isink max. Pulses per revolution Fan description Basic type DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans Signal data Type 5200 N DV 5200 5112 N 5114 N / 5118 N 5300 5300 TD 7112 N / 7118 N 7114 N 7200 N 6300 6300 TD DV 6300 6400 2200 FTD RL 48 RL 65 RL 90 N RLF 100 RG 90 N RG 125 N RG 160 N RG 160 NTD RG 190 TD RG 220 TD RG 225 TD RET 97 TD REF 100 RER 120 TD RER 133 TD RER 160 NTD REF 175 TD RER 175 TD RER 190 TD RER 220 TD RER 225 TD Subject to alternations VDC mA ≤ 0,4 2 ≤ 0,4 2 ≤ 0,4 2 ≤ 0,4 2 ≤ 0,4 2 ≤ 0,4 2 ≤ 0,4 2 ≤ 0,4 2 ≤ 0,4 2 ≤ 0,4 2 ≤ 0,4 2 ≤ 0,4 2 ≤ 0,4 2 ≤ 0,4 2 ≤ 0,4 2 ≤ 0,4 2 ≤ 0,4 2 ≤ 0,4 2 ≤ 0,4 2 ≤ 0,4 2 ≤ 0,4 2 ≤ 0,4 2 ≤ 0,4 2 ≤ 0,4 2 ≤ 0,4 2 ≤ 0,4 2 ≤ 0,4 2 ≤ 0,4 2 ≤ 0,4 2 ≤ 0,4 2 ≤ 0,4 2 ≤ 0,4 2 ≤ 0,4 2 ≤ 0,4 2 ≤ 0,4 2 VDC ≤ 30 ≤ 30 ≤ 15 ≤ 60 ≤ 72 ≤ 72 ≤ 60 ≤ 30 ≤ 15 ≤ 72 ≤ 72 ≤ 72 ≤ 60 ≤ 72 ≤ 30 ≤ 30 ≤ 30 ≤ 30 ≤ 30 ≤ 30 ≤ 30 ≤ 60 ≤ 72 ≤ 72 ≤ 72 ≤ 72 ≤ 30 ≤ 72 ≤ 72 ≤ 60 ≤ 72 ≤ 72 ≤ 72 ≤ 72 ≤ 72 mA VDC 0 30 0 30 0 5 0 60 0 72 0 72 0 60 0 30 0 15 0 72 0 72 0 72 0 60 0 72 0 30 0 30 0 30 0 30 0 30 0 30 0 30 0 60 0 72 0 72 0 72 0 72 0 30 0 72 0 72 0 60 0 72 0 72 0 72 0 72 0 72 mA Page 4 2 64 4 2 65 20 2 66 20 2 66 4 2 67 20 6 68 20 2 69 20 2 69 20 2 70 20 2 72 20 6 73/74 20 6 75 20 2 76 20 6 80 4 2 95 4 2 96 4 2 97 4 2 98 4 2 99 4 2 100 20 2 101 20 6 102 20 6 103 20 6 104 20 6 105 20 6 106 4 2 107 20 6 109 20 6 113 20 6 115 20 6 116 20 6 117 20 6 118 20 6 124 20 6 125 Note: With these fan options, deviations in regard to temperature range, voltage range and power consumption are possible compared with standard fan data. 165 AC centrifugal fans Accessories Representatives Speed signal US Low Condition: Isink Speed signal US High Condition: Isource Perm. sink current Isink max. Fan description Basic type Electrical connection All voltages measured to ground. Speed signal /12 – Speed-proportional rectangular pulse for external speed monitoring of fan motor – 2, 3 or 6 pulses per revolution – TTL-compatible – Integrated pull-up resistor – Connection via separate lead – The sensor signal also serves as a major comparison variable for setting and maintaining the setpoint speed for interactive or controlled cooling with one or more interconnected fans. Signal data Type 614 N/12 GM 618 N/12 N 8412 N/12 H 4412 F/12 GM 4418 F/12 4312 /12 M 4314 /12 4182 N/12 X Subject to alternations VDC ≤ 0,4 ≤ 0,4 ≤ 0,4 ≤ 0,4 ≤ 0,4 ≤ 0,4 ≤ 0,4 ≤ 0,4 mA VDC mA mA Page 1 2,5–5,5 1 1 39 1 2,5–5,5 1 1 39 1 2,5–5,5 1 1 44 1 2,5–5,5 1 1 54 1 2,5–5,5 1 1 54 1 2,5–5,5 1 1 56 1 2,5–5,5 1 1 56 1 2,5–5,5 1 1 60 Note: With these fan options, deviations in regard to temperature range, voltage range and power consumption are possible compared with standard fan data. Alle TD Lüfter. Bsp.: 6400 TD 166 Information DC axial fans DC centrifugal fans Speed signal US Low Condition: Isink Speed signal US High Condition: Isource Perm. sink current Isink max. Fan description Basic type DC fans - specials Available on request: – Electrically isolated sensor and signal circuit – Varying voltage potentials for power and logic circuit Signal data Type VDC 7214 N/12 ≤ 0,4 6424/12 H ≤ 0,4 DV 6424/12 ≤ 0,4 DV 6448/12 ≤ 0,4 RG 125-19/12 N/12 ≤ 0,4 RG 160-28/12 N/12 ≤ 0,4 RG 160-28/18 N/12 ≤ 0,4 RER 125-19/12 N/12 ≤ 0,4 RER 160-28/12 N/12 ≤ 0,4 RER 160-28/18 N/12 ≤ 0,4 Subject to alternations mA VDC mA mA Page 2 2,5–5,5 1 ≤ 20 70 2 2,5–5,5 1 ≤ 20 76 2 4,5–5,25 2 ≤ 12 78 2 4,5–5,25 2 ≤ 12 78 1 2,5–5,5 1 ≤ 1 100 2 2,5–5,5 1 ≤ 5 101 2 2,5–5,5 1 ≤ 20 101 1 2,5–5,5 1 ≤ 1 112 2 2,5–5,5 1 ≤ 5 114 2 2,5–5,5 1 ≤ 20 114 Note: With these fan options, deviations in regard to temperature range, voltage range and power consumption are possible compared with standard fan data. ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Representatives 167 Alarm signal /17 – Alarm signal for speed monitoring – Signal output via open collector – The fan emits a high continuous signal during trouble-free operation within the permissible voltage range. – Low signal when speed limit is not reached – After elimination of fault, the fan returns to its setpoint speed; the alarm signal reverts to high. Alarm output voltage UA Low Condition: Condition: Isink = Alarm outputvoltage UA High Condition: Condition: Isource Alarm operatingvoltage UBA max. Max. permissible Sink current Alarm delay time t2 Condition: Speed limit nG Fan description Basic type Alarm signal data Type 8318 /17 8318 /17 H 3314 /17 4318 /17 4184 N /17 X Subject to alternations VDC mA VDC mA VDC mA ≤ 0,4 n < nG 2 ≤ 60 n > nG 0 60 20 ≤ 0,4 n < nG 2 ≤ 60 n > nG 0 60 20 ≤ 0,4 n < nG 2 ≤ 60 n > nG 0 60 20 ≤ 0,4 n < nG 2 ≤ 60 n > nG 0 60 20 ≤ 0,4 n < nG 2 ≤ 60 n > nG 0 60 20 Note: With these fan specials, deviations as regards temperature range, voltage range and power consumption are possible compared with standard fans. s RPM Page ≤ 15 * 1500 ± 100 46 ≤ 15 * 1500 ± 100 46 ≤ 15 * 1500 ± 100 50 ≤ 15 * 850 ± 100 56 ≤ 15 * 1500 ± 100 60 Electrical connection Ra All voltages measured to ground. External load resistor Ra from UA to UBA required. 168 t2 = Alarm signal suppression during start-up * n < speed limit nG by braking or locking. Information DC axial fans DC centrifugal fans DC fans - specials Available on request: – With integrated signal latching for subsequent recognition of short-time faults – Alarm circuit open collector or TTL – Electrically isolated for maximum device safety Defects in the power circuit do not affect the alarm circuit. Fan description Basic type Condition: Isource Alarm operatingvoltage UBA max. Max. permissible Sink current Alarm delay time t2 Condition: Speed limit nG Alarm output voltage UA Low Condition: Condition: Isink = Alarm outputvoltage UA High Condition: Alarm signal data Type 4312/17 MT VARIOFAN 4312/17 T VARIOFAN 4314/17 T VARIOFAN 4318/17 T VARIOFAN 7214 N/17 Subject to alternations VDC ≤ 0,4 n < nG mA VDC 2 ≤ 60 n > nG ≤ 0,4 n < nG 2 ≤ 60 n > nG ≤ 0,4 n < nG 2 ≤ 60 n > nG ≤ 0,4 n < nG 2 ≤ 60 n > nG ≤ 0,4 n < nG 2 ≤ 60 n > nG Note: With these fan specials, deviations as regards temperature range, voltage range and power consumption are possible compared with standard fans. mA VDC mA 0 60 20 0 60 20 0 60 20 0 60 20 0 60 15 s RPM Page ≤ 15 * 1500 ± 100 57 ≤ 15 * 1500 ± 100 57 ≤ 15 * 1150 ± 100 57 ≤ 15 * 850 ± 100 57 ≤ 15 * 1330 ± 60 70 * After switching on UB ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Representatives 169 Alarm signal /19 – Alarm signal for speed monitoring – Signal output via open collector – The fan emits a low continuous signal during trouble-free operation within the permissible voltage range. – High signal when speed limit is not reached – After elimination of fault, the fan returns to its setpoint speed; the alarm signal reverts to low. Alarm output voltage UA Low Condition: Condition: Isink = Alarm outputvoltage UA High Condition: Condition: Isource Alarm operatingvoltage UBA max. Max. permissible Sink current Alarm delay time t2 Condition: Speed limit nG Fan description Basic type Alarm signal data Type VDC 8314/19 H ≤ 0,4 4312/19 ≤ 0,4 7214 N/19 ≤ 0,4 RLF 100-11/14/19 ≤ 0,4 RER 101-36/18N/19 HH ≤ 0,4 Subject to alternations n > nG n > nG n > nG n > nG n > nG mA VDC 2 ≤ 60 n < nG 2 ≤ 60 n < nG 2 ≤ 60 n < nG 2 ≤ 28 n < nG 2 ≤ 28 n < nG mA VDC mA 0 60 20 0 60 20 0 60 10 0 28 10 0 28 10 Note: With these fan specials, deviations as regards temperature range, voltage range and power consumption are possible compared with standard fans. Available on request: – With integrated signal latching for subsequent recognition of short-term faults. – Alarm circuit open collector or TTL. – Electrically isolated for max. device safety; defects in power circuit have no effect on the alarm circuit. Electrical connection s ≤ 15 ≤ 15 10 ± 4 10 ± 4 10 ± 4 RPM Page * 1500 ± 100 46 * 1500 ± 100 56 * 1800 ± 20 70 * 1900 ± 100 98 * 1900 ± 100 108 * After switching on UB Ra All voltages measured to ground. External load resistor Ra from UA to UBA required. 170 t2 = Alarm signal suppression during start-up. * n < Speed limit nG by braking or locking. Information Alarm signal /37 Go / No-go alarm – Alarm signal for speed monitoring – Signal output via open collector – The fan emits a high continuous signal during trouble-free operation within the permissible voltage range. – Low signal when speed limit is not reached – After elimination of fault, the fan returns to its setpoint speed; the alarm signal reverts to high. DC axial fans DC centrifugal fans Fan description Basic type Condition: Isource Alarm operatingvoltage UBA max. Max. permissible Sink current Alarm delay time t2 Condition: Speed limit nG Alarm output voltage UA Low Condition: Condition: Isink = Alarm outputvoltage UA High Condition: DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans Alarm signal data Type VDC mA VDC mA VDC mA 8412 N/37 GMLV ≤ 0,4 n ≤ nG 2 ≤ 28 n > nG 0 28 10 3412 N/37 GV ≤ 0,4 n ≤ nG 2 ≤ 28 n > nG 0 28 10 Subject to alternations Note: With these fan specials, deviations as regards temperature range, voltage range and power consumption are possible compared with standard fans. s RPM Page <1 * 0 45 <1 * 0 49 * After switching on UB Available on request: – Alarm circuit TTL compatible. Electrical connection Ra All voltages measured to ground. External load resistor Ra from UA to UBA required. t2 = Alarm signal suppression during start-up. * n < Speed limit nG by braking or locking. 171 AC centrifugal fans Accessories Representatives Alarm signal /39 Go / No-go alarm – Alarm signal for speed monitoring – Signal output via open collector – The fan emits a low continuous signal during trouble-free operation within the permissible voltage range. – High signal when speed limit is not reached – After elimination of fault, the fan returns to its setpoint speed; the alarm signal reverts to low. Alarm output voltage UA Low Condition: Condition: Isink = Alarm outputvoltage UA High Condition: Condition: Isource Alarm operatingvoltage UBA max. Max. permissible Sink current Alarm delay time t2 Condition: Speed limit nG Fan description Basic type Alarm signal data Type 412/39 612 F/39 H 614 N/39 M 618 N/39 N 3412 N/39 H 3414 N/39 HH 4412 F/39 GL 4412 F/39 M 4414 F/39 4414 FN/39 H Subject to alternations VDC mA VDC mA VDC mA ≤ 0,5 n > nG 2 ≤ 28 n = nG 0 28 10 ≤ 0,5 n > nG 2 ≤ 28 n = nG 0 28 10 ≤ 0,5 n > nG 2 ≤ 28 n = nG 0 28 10 ≤ 0,5 n > nG 2 ≤ 28 n = nG 0 28 10 ≤ 0,5 n > nG 2 ≤ 28 n = nG 0 28 10 ≤ 0,5 n > nG 2 ≤ 28 n = nG 0 28 10 ≤ 0,5 n > nG 2 ≤ 28 n = nG 0 28 10 ≤ 0,5 n > nG 2 ≤ 28 n = nG 0 28 10 ≤ 0,5 n > nG 2 ≤ 28 n = nG 0 28 10 ≤ 0,4 n > nG 2 ≤ 30 n = nG 0 30 4 Note: With these fan specials, deviations as regards temperature range, voltage range and power consumption are possible compared with standard fans. Electrical connection s RPM Page <1 *0 33 <1 *0 36 <1 *0 39 <1 *0 39 <1 *0 48 <1 *0 48 <1 *0 54 <1 *0 54 <1 *0 54 <1 *0 55 * After switching on UB Ra All voltages measured to ground External load resistor Ra from UA to UBA required. t2 = Alarm signal suppression during start-up * n < Speed limit nG by braking or locking 172 Information DC axial fans DC centrifugal fans DC fans - specials Vario-Pro® – ”Software instead of hardware“ – aptly describes the unique fan concept, equipped at the plant with tailor-made intelligence for cooling electronics. – Flexible configuration using software, allows quicker availability, sampling from the factory and the ability to supply customer-specific solutions in any quantity. Vario-Pro-Features External Speed setting – Speed setting via temperature, PWM or analogue control voltage See page 174 (Speed setting) – Description of speed curve with up to 14 selectable interpolation points Linear interpolation between the points – Zero speed possible – Recognition of sensor failure: In case of loss of sensor, the fan operates at programmable (fail-safe) speed. Alarm and tachometer functions – Optional alarm and/or tachometer function – Selectable alarm speed limit (with hysteresis) and alarm delay time – Latching of alarm signal – Delay only when starting or permanently active – ”High“ or ”Low“ output signal in case of alarm – Optional alarm if temperature sensor fails – Optional alarm in case of excess temperature Motor management – High control accuracy due to digital motor management – Higher operating efficiency due to optimum adaptation of motor hardware and software Fan series 620 8400 N 8300 8200 J 3400 N 3300 3300 N 3200 J 3250 J 4400 FN 4300 4100 N Page 37 44 46 47 48 50 51 52 53 55 56 60 Fan series 4100 NH...NH6 4100 NH 7-8 DV 4100 5200 N DV 5200 5100 N 5300 7100 N 7200 N 6100 N 6300 DV 6300 Page 61 62 63 64 65 66 67 69 70 71 72 75 Fan series 6400 DV 6400 RL 90 N RLF 100 RG 90 N RG 125 N RG 160 N REF 100 RER 101 RER 125 N RER 160 N Page 76 78 97 98 99 100 101 107 108 112 114 ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Representatives 173 Speed setting via temperature sensor – The control variable is a temperature sensor which is either integrated into the fan or connected to an additional control wire. External temperature sensor Type T – Ext. NTC type LZ370 (p. 253) is required (to be ordered seperatly) Internal temperature sensor Type I – NTC integrated into the fan hub Standard speed-temperature curve for type T and type I n max n min 30°C 50°C nmin ≈ 1/2 nmax Tmin ≈ 30 °C; Tmax = 50 °C Optionally available with customer specific temperature-speed control curve n max n min Tmin T max nmin ≈ 800 1/min nmax model-dependent Tmin ≈ 5 °C Tmax ≤ 85 °C, model-dependent 174 Information DC axial fans DC centrifugal fans DC fans - specials Speed setting with control voltage or PWM – The control variable is a PWM signal or analogue control voltage. Speed setting via control voltage Type A – Standard control range 0 ... 10 V Typical input resistance >10 kΩ Standard curve P / A Drehzahlvorgabe mittels PWM Typ P – Standard PWM signal in two versions a) PWM frequency, mainly 1– 10 kHz (0–100%), Open collector input b) Four-wire interface in accordance with Intel specifications for 12 VDC fans, PWM frequency 25 kHz, incl. speed signal /2 R1 R2 – Optional with potentiometer R1 R2 Internal reference = +5V R1 typical 4.7...10 kΩ R2 typical 100 kΩ Optionally available with customer specific P / A speed control curve ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Representatives 175 Speed setting via multi-option control input – Customer can operate input either with PWM signal, analogue voltage, external temperature control module or resistor. – The control signal-speed characteristics of the fan differ from the standard curve of the A and P inputs (see p. 175). – To attain the maximum speed, the control wire must be switched against UB. – The control input is usually combined with an open collector tachometer (Type /2, see page 164). Speed setting via multi-option control input Notes on various control possibilities and their applications 33 K 4,7 K PWM U 10 K 12 V 12 V Temperature control module 50002-1-0174 50003-1-0174 Speed setting PWM 1 - 10 kHz Speed setting with potentiometer 100% PWM -> n=max approx. 10% PWM -> n= min < 10% PWM -> n=0 start up at > 14 % Full speed Speed setting 1 V - 10 V 10 V -> n=max approx. 1 V -> n=min < 1 V -> n=0 start up at > 1.4 V Customer circuit Line 1 Counter Controller Alarm Speed display Maximum ripple ± 3.5% red Lin/PWM control input 0-10 VDC / PWM violet Tach output pulses per revolution white GND blue Connection Isink max. 10 mA Fan + GND Tacho 0-10 V PWM red blue white violet Line Connection Colour Assignment / function 1 + red Maximum ripple ± 3.5 % GND blue GND Line Connection Colour Assignment / function 1 Tach white Tach output: 0-10 V / PWM violet 3 pulses / revolution Control input (Impedance 100 kΩ) 176 Information DC axial fans DC centrifugal fans DC fans - specials Protected fans against environmental influences – Capable to fulfil special requirements for a broad range of applications – Resistant to environmental influences, such as dust, splash water, humidity, spray water and salt fog – Highly competent solutions for adapting fans to environmental conditions Moisture protection Coated motor and printed circuit board protects against humidity and condensation. Type of protection: IP 54 / IP 68 In the type of protection IP 54, the motor and circuit boards are coated and therefore protected against spray water and moisture. The type of protection IP 68 is important for ebm-papst products, as it ensures a high degree of protection for the encapsulated motor and electronic against foreign bodies and water, whilst protecting the user against potential hazards upon contact. Types of protection higher than IP 68 are possible upon request. Salt fog protection Salt fog is extremely demanding on the resistance of the product. ebm-papst makes use of technologies that protect fans and blowers from salt fog reliably and durably. Stainless steel bearings Special bearings made of stainless steel provide additional protection. The available solutions could be different depending on the fan size. We would be glad to develop solutions tailored to the demands of your application. Type of protection – IP code Protection against foreign bodies and accidental contact (first digit) X No protection 1 Protection against foreign bodies > 50 mm (back of the hand) 2 Protection against foreign bodies > 12 mm (finger) 3 Protection against foreign bodies > 2,5 mm (tool) 4 Protection against foreign bodies > 1 mm (wire) 5 Protection against dust in harmful quantities 6 Dust-proof Water protection (second digit) X No protection 1 Protection against dripping water or condensation 2 Protection against dripping water, fans tilted 15° from vertical 3 Protection against water spray up to 60° from vertical 4 Protection against water spray from all sides 5 Protection against low-pressure water jets 6 Protection against high-pressure water jets 7 Protection against temporary submersion (15 cm - 1 m) 8 Protection against continuous submersion ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Representatives 177 178 179 Representatives Accessories AC centrifugal fans AC axial fans ACmaxx / GreenTech EC-Compact fans DC fans - specials DC centrifugal fans DC axial fans 184 Axial fans 183 Overview 180 Technical information ACmaxx / GreenTech EC-compact fans Information ACmaxx / GreenTech EC-compact fans Technical information AC ACmaxx ACi Progress made by ebm-papst The best example: The ACmaxx fans from ebm-papst, which, thanks to an ingenious yet simple improvement over conventional AC fans, provide substantial benefits. The aim in developing the new ACmaxx series was to raise the technology standard of the conventional AC fan significantly and, in the process, facilitate the transition to the new technology by retaining the overall mounting dimensions. In short, to ensure the fans can be replaced 1:1 without any peripheral changes or changes to the voltage situation. ebm-papst offers two generations of ACmaxx products that meet different needs. What ACmaxx and GreenTech EC-compact fan have in common: Energy efficiency The drive concept is based on state-of-the-art GreenTech EC technology with outstanding motor efficiency. Compared to AC fans of the same size, ACmaxx energy consumption is up to 77% lower–for higher cooling capacity! Just the energy savings means that the products pay for themselves after only a few months. The savings over the entire service life, especially in systems with multiple fans, is considerable. Independent of mains frequency and mains voltage The ACmaxx and GreenTech EC-compact fans are prepared for direct connection to all AC voltages and frequencies. The speed, and thus important properties of the fan such as air flow and noise, are independent of the power frequency and do not change, even within the defined voltage range. Voltage fluctuations in the power system are automatically compensated for. Long service life The efficiency of ACmaxx and GreenTech EC-compact fan motors is up to 75% higher than that of conventional AC fan variants. This not only saves energy, it also means less self-heating in the motor. The reduced heating has a direct, positive effect on the bearing system, which is why the fans have a service life that is up to 85% longer! This also extends the service and maintenance intervals significantly. The expense of replacement fans, and even more expensive downtimes, are kept to a manageable minimum. 180 Information ACmaxx / GreenTech EC-compact fans DC axial fans DC centrifugal fans DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans Technical information AC ACmaxx ACi Safety • Safety certifications: UL, CSA and VDE 0805 / EN60950. VDE 0700 / EN60335 on request. • Our fans have the CE mark of conformity. • EMC protection: > EN61000-4-4 Level 1 (1 kV or 2 kV)B > EN61000-4-2 Level 8 kV/15 kV or 4 kV/8 kV > EN61000-4-3 > EN61000-4-6 > EN61000-4-8 > EN55022 Class B GreenTech EC-compact fan is more efficient! ACmaxx saves energy, and the GreenTech EC-compact fan generation saves even more. While an AC fan at 50 Hz can barely reach an overall efficiency of 5-6%, the ACmaxx makes it to approx. 20-25%. With the new GreenTech EC-compact fans ACi 4400, a remarkable level of up to 30% is reached. This is the result of the optimisation of the entire package made up of drive, electronics, AC/DC conversion and aerodynamics. Thus the new GreenTech EC-compact fans series boasts energy savings of almost 75% compared to the corresponding AC fan, thus providing significantlyhigher savings than the 40% level of the old AC 4300 generation. Ambient influences AC fans are extremely common and are used in a wide variety of applications. In control cabinet cooling, beer coolers, cooling cabinets, wood-burning stoves, medical devices – all have different requirements for resistance to ambient influences. ACmaxx and GreenTech EC-compact fans offer the same features for protection against moisture, splash water and rough ambient conditions. Particular design features of the GreenTech EC-compact fan (ACi 4400): GreenTech EC-compact fan is more compact! As large as existing AC fans – and not a bit larger. This is the most outstanding feature of the new GreenTech EC-compact fans ACi 4400. Even in the hub area, the fan does not differ from typical 119 x 119 x 38 mm AC fans. Out with the AC, in with the GreenTech EC-compact fans ACi 4400 – it's that simple. GreenTech EC-compact fan is quieter! The GreenTech EC-compact fan ACi 4400 is quieter! Quieter than AC fans and quieter than the existing ACmaxx generation. The reason for this are the optimised aerodynamics and the drive, which is optimised for minimum structure-borne noise. Thus the fan is only half as loud at comparable air performance, and is up to 6 dB(A) quieter at some operating points. ACmaxx ACi Speed independent of voltage and frequency For the GreenTech EC-compact fans ACi 4400, the speed, and thus the air flow and operating noise, are independent of the supply voltage and power frequency. Versions are available for 115 VAC with a voltage range from 85 to 132 VAC and 230 VAC with a voltage range of 195 to 265 VAC. Voltage fluctuations and frequency differences in the power system are compensated for automatically. 181 AC centrifugal fans Accessories Representatives ACmaxx / GreenTech EC-compact fans Technical information AC ACmaxx ACi Particular design features of the ACmaxx: Prepared for all AC voltages These types have a very wide voltage range from 85 to 265 VAC – the global voltage range, so to speak. This enables the fan to be used around the world, opening up large savings potentials. In addition to reduced logistics effort and stock-keeping, worldwide availability is key. ACmaxx is compatible with every supply voltage–no switching needed. From 85 to 265 volts and mains frequencies of 50 and 60 hertz. Voltage fluctuations in the power system are automatically compensated for. setting to long-term function checks using an alarm or speed signal outputs, ACmaxx offers optional interfaces that allow you to monitor operation quickly and easily. You can find further information about these fan options in the "Specialised fans" chapter, starting on page 161. Or you can simply contact our application engineers to discuss your ideal ACmaxx or GreenTech EC-compact fan. Higher performance Unlike conventional AC technology, the state-of-the-art drive concept of this fan series is not linked to a fixed power frequency. This allows the motor speed to be increased over a wide range. Thus ACmaxx provides significantly higher air flow and significantly increased pressure. Higher flexibility The flexibility of ACmaxx is one-of-a-kind. With its intelligent features, ACmaxx can be individually adapted to the specific application: standby mode, overload mode at peak times or night reduction all the way to temperature-controlled quiet operation are all possible. From speed 182 Information DC axial fans Page DC centrifugal fans Fans for AC operation Overview of air performance Dimension Series Air flow mm m3/h 10 c 80 x 32 AC 8300 H 80 c 92 x 38 AC 3200 J 144 c 119 x 25 AC 4400 FN 205 c 119 x 32 AC 4300 204 c 119 x 38 ACi 4400 100...175 Ø 130 W1G 130 220...370 Ø 172 x 51 AC 6100 N 350 Ø 172 x 51 AC 6200 N 350 Ø 200 W3G 200 560...1000 Ø 250 W3G 250 900...1700 Ø 98,5 x 130 AC 100 NR 80..105 Subject to alternations 20 108 109 110 18 30 40 50 60 70 80 90 100 Overview of technically feasible designs 200 300 400 500 600 700 800 900 1000 2000 3000 184 185 186 187 188 190 192 193 194 196 198 DC fans - specials ACmaxx / GreenTech EC-Compact fans IIIAPEPSAHGnlPPMxatanouatluWeglrta/>>elrtmeirfMionm==-NnodgacIIioolagtluwoPP-pitytettnpgiet65rehpoorcor84lmnotoimalopletnpictmeaceieronrrttcironpatloiattmsutriontupuornnlerepieeunsdtspeeunntssoorr bearings ball / Sintec sleeve bearings Speed signal VDE, UL, CSA Dimension AC axial fans AC centrifugal fans ACmaxx / ACi Axial fans Series mm AC 8300 H 80 x 80 x 32 * AC 3200 J 92 x 92 x 38 * AC 4400 FN 119 x 119 x 25 * AC 4300 119 x 119 x 32 * ACi 4400 119 x 119 x 38 * AC 6100 N Ø 172 x 51 * AC 6200 N Ø 172 x 51 * AC 100 NR Ø 100 x 130 * Subject to alternations OPTIONAL p. • • • • • • • – • • – • 184 • • • • • • • – • • – • 185 • • • • • • • – • – – – 186 • • • • • • • – • • • • 187 – – – – – – – – • • – • 188 • • • • • • • – • – – – 192 • • • • • • • – • • – • 193 – – – – – – – – • • – – 198 – not yet available • available Sleeve bearings Ball bearings * Partially granted, partially in registration stage. Please note that these special versions are not possible for all voltages and speeds, and not in all combinations. The special versions are designed for specific customers and projects. As a rule they are not available off the shelf and are tied to minimum volumes. Please consult your customer support representative about the feasibility of your special variant. 183 Accessories Representatives 80 max. m3/h ACmaxx axial fans Series AC 8300 H 80 x 80 x 32 mm – Material: Housing: GRP1) (PBTP) Impeller: GRP1) (PA) – Direction of air flow: Exhaust over struts – Direction of rotation: Clockwise, seen on rotor – Connection: Via single wires AWG 22, TR 64 – Highlights: Universally usable for all mains voltages between 85 and 265 VAC – Mass: 325 g 1) Fibreglass-reinforced plastic – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Protection against moisture - Protection against salt fog - Type of protection: IP 54 Air flow Air flow Nominal voltage Frequency Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 at 40 °C at Tmax Curve Nominal data Type m3/h CFM V Hz VAC dB(A) Bel(A) AC 8300 H Subject to alternations 80 47 115 / 230 50 / 60 85 ... 265 48 6,2 Speed variants available on request. / Watts rpm °C Hours Hours / 8,3 5 000 -20...+75 55 000 / 25 000 ➀ Pa [in H2O] 120 1 0, 4 100 80 0, 3 60 0,2 40 0, 1 20 0 8 16 24 32 40 CFM 10 20 30 40 50 60 m³/h 184 Guard grilles p. 240 5 22 32 + 0,3 64 + 0,5 tin-plated Information DC axial fans DC centrifugal fans max. 144 m3/h ACmaxx axial fans Series AC 3200 J 92 x 92 x 38 mm – Material: Housing: GRP1) (PBTP) Impeller: GRP1) (PA) – Direction of air flow: Exhaust over struts – Direction of rotation: Clockwise, seen on rotor – Connection: Via single wires AWG 22, TR 64 – Highlights: Universally usable for all mains voltages between 85 and 265 VAC – Mass: 325 g 1) Fibreglass-reinforced plastic – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Protection against moisture - Protection against salt fog - Type of protection: IP 54 Air flow Air flow Nominal voltage Frequency Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 at 40 °C at Tmax Nominal data Type m3/h CFM V Hz VAC dB(A) Bel(A) AC 3200 JH Subject to alternations 144 85 115 / 230 50 / 60 85 ... 265 55 6,4 Speed variants available on request. / Watts rpm °C Hours Hours / 12 6 800 -20...+70 70 000 / 35 000 ➀ DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Pa [in H O] 2 Accessories 0,1 0,2 0,3 0,4 0,5 0,6 0,7 1 200 160 120 80 40 0 15 30 45 60 75 CFM 20 40 60 80 100 120 m³/h Guard grilles p. 240 61.7+ 0.2 54.2 + 0.15 tin-plated 6+ 0.3 6+ 0.3 38+ 0.5 70.7 + 0.8 0.3 185 Representatives max. 205 m3/h ACmaxx axial fans Series AC 4400 FN 119 x 119 x 25 mm – Material: Housing: GRP1) (PBTP) Impeller: GRP1) (PA) – Direction of air flow: Exhaust over struts – Direction of rotation: Counter-clockwise, seen on rotor – Connection: Via single wires AWG 22, TR 64 – Highlights: Universally usable for all mains voltages between 85 and 265 VAC – Mass: 370 g – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Protection against moisture 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Frequency Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 at 40 °C at Tmax Nominal data Type AC 4400 FNN Subject to alternations m3/h CFM V Hz VAC dB(A) Bel(A) 205 121 115 / 230 50 / 60 85 ... 265 53 6,2 Speed variants available on request. / Watts rpm °C Hours Hours / 12 4 850 -20...+70 60 000 / 30 000 ➀ Pa [in H2O] 0,1 0,2 0,3 0,4 0,5 150 1 125 100 75 50 25 0 30 60 90 120 150 CFM 50 100 150 200 250 m³/h 186 Guard grilles p. 240 tin-plated 25.4 + 0.15 57.9 + 0.5 Information DC axial fans DC centrifugal fans max. 204 m3/h ACmaxx axial fans Series AC 4300 119 x 119 x 32 mm – Material: Housing: GRP1) (PBTP) Impeller: GRP1) (PA) – Direction of air flow: Exhaust over struts – Direction of rotation: Clockwise, seen on rotor – Connection: Via single wires AWG 22, TR 64 – Highlights: Universally usable for all mains voltages between 85 and 265 VAC – Mass: 325 g 1) Fibreglass-reinforced plastic – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Protection against moisture - Protection against salt fog - Type of protection: IP 54 / IP 68 Kennlinie Service life L10 at 40 °C at Tmax Temperature range Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Air flow Air flow Nominal voltage Frequency Nominal data Type AC 4300 H Subject to alternations m3/h CFM V Hz VAC dB(A) Bel(A) 204 120 115 / 230 50 / 60 85 ... 265 51 6,4 Speed variants available on request. / Watts rpm °C Hours Hours / 12 3 400 -20...+70 45 000 / 22 500 ➀ DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans [in H O] 2 Pa Accessories 0, 3 1 80 60 40 20 0, 2 0, 1 0 15 30 45 60 75 90 CFM 25 50 75 100 125 150 m³/h Guard grilles p. 240 tin-plated 187 Representatives max. 175 m3/h GreenTech EC-Compact fan axial fans Series ACi 4400 119 x 119 x 38 mm – Material: Housing: GRP1) (PBT) Impeller: GRP1) (PA) – Direction of air flow: Exhaust over struts – Direction of rotation: Clockwise, seen on rotor – Connection: via 2 flat plugs 2,8 x 0,5 mm flying leads optional – Highlights: Fully integrated converter and fan electronics – Mass: 250 g – Possible special versions: (See chapter DC fans - specials) - Protection against moisture - Protection against salt fog - Type of protection: IP 54 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10IPC (40 °C) see page 17 Curve Nominal data Type ACi 4420 ML ACi 4420 N ACi 4420 H ACi 4420 HH ACi 4410 HH Subject to alternations m3/h CFM VDC VDC dB(A) Bel(A) / 100 59 147 86 160 94 175 106 230 195...265 25 4,1 230 195...265 36 4,9 230 195...265 39 5,1 230 195...265 42 5,3 175 106 115 85...132 42 5,3 Watts 1,4 2,8 3,3 4,4 4,4 rpm 1 850 2 700 3 000 3 300 3 300 °C -20...+75 -20...+75 -20...+75 -20...+75 -20...+75 Hours Hours 65 000 / 25 000 110 000 ➀ 65 000 / 25 000 110 000 ➁ 65 000 / 25 000 110 000 ➂ 65 000 / 25 000 110 000 ➃ 65 000 / 25 000 110 000 ➃ 38 +0,5 6 +0,3 6 +0,3 188 Guard grilles p. 240 Connection cables p. 251 189 Representatives Accessories AC centrifugal fans AC axial fans ACmaxx / GreenTech EC-Compact fans DC fans - specials DC centrifugal fans DC axial fans Information max. 370 m3/h Energy-saving axial fans Ø 130 mm – Material: – Number of blades: – Direction of air flow: – Direction of rotation: – Type of protection: – Insulation class: – Mounting position: – Condensate discharges: – Operation mode: – Bearings: Wall ring: Plastic PP, fibreglass-reinforced Blades: Plastic PA, fibreglass-reinforced 7 "V", exhaust over struts Counter-clockwise, seen on rotor IP 54 "B" Any None Continuous operation (S1) Maintenance-free ball bearings Curve Nominal voltage Frequency Speed / rpm(1) Max.input power(1) Max.current draw(1) Max. back-pressure Perm. amb. temp. Mass Electrical connections Nominal data Type W1G130-AA49 -01 W1G130-AA25 -01 Subject to alternations Motor VAC Hz rpm W A Pa °C kg M1G 055-AI A 1~ 115 50/60 3200 24 0,38 M1G 055-AI B 1~ 230 50/60 3200 24 0,19 (1) Nominal data in operating point with maximum load and 115 or 230 VAC 90 -30..+60 0,75 90 -30..+70 0,75 p. 259 / J7) p. 259 / J7) Curve: A n Ped I LWA B rpm W A dB(A) A 1 3200 23 0,38 63 A 2 3200 24 0,38 61 A 3 3200 24 0,38 60 A 4 3200 24 0,38 63 A 5 2800 16 0,26 60 A 6 2800 16 0,26 58 A 7 2800 16 0,26 57 A 8 2800 16 0,26 60 B 1 3200 23 0,19 63 B 2 3200 24 0,19 61 B 3 3200 24 0,19 60 B 4 3200 24 0,19 63 B 5 2800 16 0,13 60 B 6 2800 16 0,13 58 B 7 2800 16 0,13 57 B 8 2800 16 0,13 60 190 Air performance measured as per: ISO 5801, Installation category A, with ebm-papst inlet nozzle without protection against accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted! For detailed information see http://www.ebmpapst.com/general conditions Information DC axial fans – Motor protection: Via electronics and TOP – Electrical connection: Plug-in connection on motor side – Protection class: II – Product conforming to standards: CE; EN 60335-1 – Approvals: VDE, UL, CSA, GOST are applied for – Speed: Using the programming unit 2 speeds between nmin and nmax can be programmed DC centrifugal fans DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories ❮ "V" Guard grilles from p. 238 Electrical connections p. 259 Connection lead (total length 450 mm) is fitted ex works and can be detached. 191 Representatives max. 350 m3/h ACmaxx axial fans Series AC 6100 N 172 x 160 x 51 mm – Material: Housing: GRP1) (PA) Impeller: GRP1) (PA) – Direction of air flow: Exhaust over struts – Direction of rotation: Counter clockwise, seen on rotor – Connection: Via single wires AWG 22, TR 64 – Highlights: Universally usable for all mains voltages between 85 and 265 VAC, 50-60 Hz – Mass: 760 g – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Protection against moisture 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Frequency Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 at 40 °C at Tmax Curve Nominal data Type m3/h CFM V Hz VAC dB(A) Bel(A) AC 6100 NM Subject to alternations 350 206 115 / 230 50 / 60 85 ... 265 52 6,1 Speed variants available on request. / Watts rpm °C Hours Hours / 14 2 850 -20...+70 80 000 / 37 500 ➀ Pa [in H2O] 0,1 0,2 0,3 0,4 0,5 150 1 125 100 75 50 25 0 40 80 120 160 200 CFM 100 200 300 m³/h 192 Guard grilles p. 240 tin-plated 8,2 deep Information DC axial fans DC centrifugal fans max. 350 m3/h ACmaxx axial fans Series AC 6200 N Ø 172 x 51 mm – Material: Housing: Die-cast aluminium Impeller: GRP1) (PA) – Direction of air flow: Exhaust over struts – Direction of rotation: Counter clockwise, seen on rotor – Connection: Via single wires AWG 22, TR 64 – Highlights: Universally usable for all mains voltages between 85 and 265 VAC, 50-60 Hz Housing with grounding lug for screw M4 x 8 (Torx) – Mass: 900 g 1) Fibreglass-reinforced plastic – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Protection against moisture - Protection against salt fog - Type of protection: IP 54 Air flow Air flow Nominal voltage Frequency Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 at 40 °C at Tmax Curve Nominal data Type m3/h CFM V Hz VAC dB(A) Bel(A) AC 6200 NM Subject to alternations 350 206 115 / 230 50 / 60 85 ... 265 50 5,7 Speed variants available on request. / Watts rpm °C Hours Hours / 14 2 850 -20...+70 80 000 / 40 000 ➀ DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Pa 0,4 [in H2O] 0, 3 1 100 75 50 25 0, 2 0,1 0 50 100 150 CFM 100 200 300 m³/h Guard grilles p. 240 74 63,7 166 10 83,3 +0,6 0,8 0,8 7,5 7,5 15 30,5 +0,2 tin-plated 8,2 deep 193 Representatives max. 1000 m3/h EC axial fans Ø 200 mm – Material: – Number of blades: – Direction of air flow: – Direction of rotation: – Type of protection: – Insulation class: – Mounting position: – Condensate discharges: – Operation mode: – Bearings: Wall ring: Die-cast aluminium Blades: Plastic PP Rotor: Thick layer passivated 7 "V", exhaust over struts Counter-clockwise, seen on rotor IP 54 "B" Any None, open rotor Continuous operation (S1) Maintenance-free ball bearings Curve Nominal voltage Frequency Speed / rpm(1) Max. input power(1) Max. current draw(1) Max. back-pressure Perm. amb. temp. Mass Technical features and electrical connection Nominal data Type W3G200-HD01 -01 W3G200-HD01 -03 Subject to alternations Motor VAC Hz rpm W A Pa °C kg M3G 055-BD A 1~ 230 50/60 2900 54 0,55 M3G 055-BD B 1~ 230 50/60 2900 54 0,55 (1) Nominal data in operating point with maximum load and 230 VAC 96 -25..+60 1,6 96 -25..+60 1,7 p. 256 / H3) p. 257 / H4) 0,04 0,08 0,12 0,16 0,20 0,24 0,28 0,32 0,36 0,40 in H2O Pa Curve: 100 A 2 Speed stages 90 B Speed-controlled 80 70 B A Step 2 4 A Step 1 8 3 60 7 50 40 2 30 6 20 10 pfs 5 1 0 100 200 300 400 500 cfm qV 200 400 600 800 m3/h Air performance measured as per: ISO 5801, Installation category A, without protection against accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted! For detailed information see http://www.ebmpapst.com/general conditions n Ped rpm W A 1 2970 50 A 2 2890 54 A 3 2830 58 A 4 2900 54 A 5 2645 36 A 6 2575 39 A 7 2530 42 A 8 2500 43 B 1 2970 50 B 2 2890 54 B 3 2830 58 B 4 2900 54 I LWA A dB(A) 0,49 65 0,53 64 0,56 65 0,55 70 0,37 62 0,40 61 0,42 62 0,43 67 0,49 65 0,53 64 0,56 65 0,55 70 194 Information DC axial fans – Technical features: – EMC: – Touch current: – Electrical connection – Protection class: – Product conforming to standards: – Approvals: See electrical connections p. 256/257 Interference immunity acc. to EN 61000-6-2 (industrial environment) Harmonics acc. to EN 61000-3-2/3 Interference emission acc. to EN 55022 (class B, household environment) On account of the installation conditions, ferritic damping in the connection line may be required for the application. <= 3.5 mA acc. to IEC 60990 (test circuit, illustration 4) Via terminal strip I (if customer has provided connection for protective earth) EN 60335-1, CE cURUS DC centrifugal fans DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans A B 225 Ø4.5 (8x) Ø240 Ø260 4 4 80±0.3 "V" "V" Guard grilles from p. 238 Electrical connections p. 256/257 195 Accessories Representatives max. 1700 m3/h EC axial fans Ø 250 mm – Material: – Number of blades: – Direction of air flow: – Direction of rotation: – Type of protection: – Insulation class: – Mounting position: – Condensate discharges: – Operation mode: – Bearings: Wall ring: Die-cast aluminium Blades: Plastic PP Rotor: Thick layer passivated 7 "V", exhaust over struts Counter-clockwise, seen on rotor IP 54 "B" Any None, open rotor Continuous operation (S1) Maintenance-free ball bearings Curve Nominal voltage Frequency Speed / rpm(1) Max. input power(1) Max. current draw(1) Max. back-pressure Perm. amb. temp. Mass Technical features and electrical connection Nominal data Type W3G250-HH07 -01 W3G250-HH07 -03 Subject to alternations Motor VAC Hz rpm W A Pa °C kg M3G 055-CF A 1~ 230 50/60 2330 83 0,72 100 -25...+60 2,0 M3G 055-CF B 1~ 230 50/60 2330 83 0,72 (1) Nominal data in operating point with maximum load and 230 VAC 100 -25...+60 2,1 p. 256 / H3) p. 257 / H4) 0,04 0,08 0,12 0,16 0,20 0,24 0,28 0,32 0,36 0,40 in H2O Pa Curve: 100 A 2 Speed stages 90 B Speed-controlled 80 70 60 AB Step 2 4 A 3 Step 1 8 50 7 40 2 30 6 20 10 pfs 5 1 0 100 200 300 400 500 600 700 800 900 1000cfm qV 200 400 600 800 1000 1200 1400 1600 m3/h Air performance measured as per: ISO 5801, Installation category A, without protection against accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted! For detailed information see http://www.ebmpapst.com/general conditions n Ped rpm W A 1 2465 67 A 2 2410 75 A 3 2375 80 A 4 2330 83 A 5 1900 33 A 6 1880 37 A 7 1860 40 A 8 1850 42 B 1 2465 67 B 2 2410 75 B 3 2375 80 B 4 2330 83 I LWA A dB(A) 0,59 69 0,65 69 0,68 68 0,72 69 0,33 63 0,37 63 0,38 62 0,40 63 0,59 69 0,65 69 0,68 68 0,72 69 196 Information DC axial fans – Technical features: – EMC: – Touch current: – Electrical connection – Protection class: – Product conforming to standards: – Approvals: See electrical connections p. 256/257 Interference immunity acc. to EN 61000-6-2 (industrial environment) Harmonics acc. to EN 61000-3-2/3 Interference emission acc. to EN 55022 (class B, household environment) On account of the installation conditions, ferritic damping in the connection line may be required for the application. <= 3.5 mA acc. to IEC 60990 (test circuit, illustration 4) Via terminal strip I (if customer has provided connection for protective earth) EN 60335-1, CE cURUS DC centrifugal fans DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans 20° 15° 280 A B Ø290 PE NL Ø4.4+0.2(8x) Ø5.5+0.2(8x) Ø295 Ø320 7 7 80 "V" "V" Guard grilles from p. 238 Electrical connections p. 256/257 197 Accessories Representatives max. 105 m3/h ACmaxx in-line duct fan Series AC 100 NR Ø 98,5 x 130 mm – Material: Housing: GRP1) (PBT) – Possible special versions: Impeller: GRP1) (PA) (See chapter DC fans - specials) – Direction of air flow: Intake over struts - Protection against moisture – Direction of rotation: Clockwise, seen on rotor - Type of protection: IP 44 (IP 45 – Connection: Via 3-pin Europa terminal strip possible depending on mounting max. 1,5 mm2 position) – Highlights: Universally usable for all mains voltages between 85 and 265 VAC, 50-60 Hz Boost function Vibration-isolated motor – Mass: 400 g 1) Fibreglass-reinforced plastic L10 Curve at Tmax Service life at 40 °C Temperature range Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Air flow Air flow Nominal voltage Frequency Nominal data Type nominal AC 100 NR boost Subject to alternations m3/h CFM V Hz VAC dB(A) Bel(A) 80 47 35 4,7 115/230 50-60 85...265 105 62 42 5,3 Optional: Max. speed up to 135 m3/h (Curve 3). / Watts rpm °C Hours Hours 2,5 2 750 ➀ 4,5 3 500 -10...+55 70 000 / 40 000 ➁ [in H2O] Pa 3 70 0,16 60 50 2 0,12 40 30 1 0,08 20 10 0 20 40 60 80 CFM 20 40 60 80 100 120 m³/h 198 Information DC axial fans DC centrifugal fans DC fans - specials Highest energy efficiency: 0.03 - 0.045 W/m3/h free air (Specific fan power). Boost speed setting: 2 speed settings possible via boost function. Vibration isolation: Reduced transmission of vibrations from motor to housing. Intelligence: Speed settings and control outputs optional. Connection Scope of delivery Example 1: Continuous operation at nominal speed boost speed via light switch. N L Example 3: Simple connection, nominal speed without switching. N L Example 2: Nominal speed via light switch, separate boost switch. N L Example 4: Simple connection, boost speed without switching. N L ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Representatives 199 200 201 Representatives Accessories AC centrifugal fans AC axial fans ACmaxx / GreenTech EC-Compact fans DC fans - specials DC centrifugal fans DC axial fans 204 AC axial fans 203 AC axial fan overview AC axial fans Information AC axial fans Technical information Product line The renowned ebm-papst AC fans are used when DC voltage is not available. The AC range of fans is based on experience gained from decades of development activity, millions of units in series production and competence in innovation of a world-wide technological leader. A wide range of fans for AC operation is presented in this catalogue. In addition to complete device fans, you will also find fans without external housing, providing a particularly economical advantage when the air duct can be integrated in the respective device. Variety of sizes AC fans are available in a variety of sizes with either air exhaust or air intake over struts. Silent running models with sleeve bearings (or for extreme ambient conditions) fans with ball bearings are available. Electrical connection with plug connection or external leads are available. Bearings AC fans with sleeve bearings are powered by Class E insulated motors. Fans with ball bearings are equipped with Class B, E or F insulated motors. Type of protection All fans are equipped with type of protection IP 20 as standard. IP 54 / IP 68 and further types of protection are available on request. AC voltage The line of AC fans for Euro voltage according to IEC 60038 (230 V + 6 %, -10 %) is basically also available for 115 V. Frequencies AC fans can be operated at frequencies of 50 Hz or 60 Hz. However, their technical data then changes accordingly. Shaded-pole or capacitor motors Fan drives by shaded-pole or capacitor motors, most of which incorporate the world-famous ebm-papst external rotor principle: The fan blades are directly attached to the external rotor of the external rotor motor, thus combining both high performance and profitability. Flat built AC fans ebm-papst also has particularly flat built AC fans with internal rotor motor. Their advantage: quick start to full speed. A plastic impeller and the both smaller and lighter internal rotor motor lead to a lower moment of inertia. Capacitor Fans driven by capacitor external motors provide particularly high operating efficiency. Generally, the required operating capacitor is already integrated in the fan housing. Overloading Almost all AC fans are protected against overloading (e.g. due to locked rotor) the drive motors are either impedance protected (marked “Impedance protected”, and/or “Z.P.”) or are equipped with a thermal switch (marked “Thermally protected” or “Th.P.”). The model designation of these fans ends with “S”. 202 Information DC axial fans DC centrifugal fans DC fans - specials Axial fans for AC operation Overview of air performance Dimension Series Air flow Page mm c 80 x 38 8000 N Ø 76 x 37 8000 TV c 92 x 25 3900 c 92 x 38 3000 c 119 x 25 9900 c 119 x 38 4000 N c 119 x 38 4000 Z Ø 108 x 37 4600 TZ c 127 x 38 5900 c 135 x 38 5600 150 x 172 x 38 7000 Ø 150 x 55 7800 Ø 150 x 55 7400 Ø 172 x 51 6000 c 225 x 80 W2E 200 c 280 x 80 W2E 250 Ø 200 K2E 200 Ø 200 K2E 200 Ø 200 K2D 200 Subject to alternations m3/h 10 30...61 24...47 31...70 49...89 84...135 80...180 100...180 125...140 150...206 129 235...270 320...380 325...380 380...425 375...500 880...1030 1865 765...840 765...850 780...880 20 30 40 50 60 70 80 90 100 200 300 400 500 600 700 800 900 1000 2000 3000 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 222 224 Overview of technically feasible designs protection protection 54 Salt fog Page IP >= IP 68 Humidity IP >= IP Speed signal VDE, UL, CSA bSianltlecbeslaereivnegbsearings/ Dimension Axial fan Series mm 8000 N 80 x 80 x 38 ja 8000 TV Ø 76 x 37 ja 3900 92 x 92 x 25 ja 3000 92 x 92 x 38 ja 9900 119 x 119 x 25 ja 4000 N 119 x 119 x 38 ja 4000 Z 119 x 119 x 38 ja 4600 TZ Ø 108 x 37 ja 5900 127 x 127 x 38 ja 5600 135 x 135 x 38 ja 7000 150 x 172 x 38 ja 7800 Ø 150 x 55 ja 7400 Ø 150 x 55 ja 6000 Ø 172 x 51 ja Subject to alternations • available – not yet available OPTIONAL p. / – • • • • 204 / – • • • • 205 / – • – – – 206 / – • • • • 207 / – • – – – 208 / • • • • • 209 / • • • • • 210 / – • • • • 211 / – • – – – 212 – • • – • 213 – – – – – 214 • – – – – 215 – – – – – 216 – – – – – 217 Sleeve bearings Ball bearings ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Representatives 203 61 max. m3/h AC axial fans Series 8000 N 80 x 80 x 38 mm – Material: Housing: Die-cast aluminium Impeller: Painted sheet steel – Direction of air flow: Exhaust over struts – Direction of rotation: Clockwise, seen on rotor – Connection: Via 2 single wires grounding lug for M4 x 8 – Mass: 490 g – Note: Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. See page 184 – Possible special versions: (See page 12) - Protection against moisture - Protection against salt fog - Type of protection: IP 54 / IP 68 Air flow Air flow Nominal voltage Frequency Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 at 40 °C at Tmax Curve Nominal data Type 8880 N 8850 N 8550 N 8556 N 8830 N 8800 N 8500 N 8506 N Subject to alternations m3/h CFM V Hz dB(A) Bel(A) / Watts rpm °C Hours Hours 30 17,7 230 50 37 21,8 230 50 50 29,4 230 50 50 29,4 230 50 18 3,3 / 9,0 1 750 -10...+80 60 000 / 25 000 ➀ 24 3,9 / 12,5 2 150 -10...+70 52 500 / 25 000 ➁ 30 4,4 / 12,0 2 700 -10...+70 52 500 / 25 000 ➂ 31 4,5 / 12,0 2 800 -40...+90 52 500 / 15 000 ➂ 36 21,2 115 60 47 27,7 115 60 61 35,9 115 60 61 35,9 115 60 21 3,7 / 8,0 1 950 -10...+80 62 500 / 25 000 ➃ 28 4,3 / 11,0 2 500 -10...+70 55 000 / 27 500 ➄ 34 4,8 / 11,0 3 200 -10...+75 55 000 / 25 000 ➅ 35 5,0 / 11,0 3 300 -40...+95 55 000 / 15 000 ➅ Fan type 8880 N 8830 N 8556 N 8506 N 8850 N 8800 N 8550 N 8500 N Lead wires 310 mm long 310 mm long 440 mm long Length “L” AWG 18, TR 64 AWG 22 AWG 18, TR 64 Pa [in H O] 2 60 6 50 3 0,20 0,15 0,10 40 25 30 4 20 1 10 0,05 0 5 10 15 20 25 30 CFM 10 20 30 40 50 m³/h 50 Hz 60 Hz 204 Guard grilles from p. 238 tin-plated Information 47 max. m3/h AC axial fans Series 8000 TV Ø 76 x 37 mm – Material: Impeller: Die-cast aluminium – Possible special versions: Mounting bracket: Metal (See page 12) – Direction of air flow: Exhaust over mounting bracket - Protection against moisture – Direction of rotation: Clockwise, seen on rotor - Protection against salt fog – Connection: Via 2 single wires - Type of protection: IP 54 / IP 68 – Mass: 370 g DC axial fans DC centrifugal fans Service life L10 at 40 °C at Tmax Temperature range Sintec sleeve bearings Ball bearings Input power Nominal speed Air flow Air flow Nominal voltage Frequency Sound pressure level DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans Nominal data Type 8880 TV 8850 TV 8550 TV 8556 TV 8830 TV 8800 TV 8500 TV 8506 TV Subject to alternations m3/h CFM V Hz 24 14,1 230 50 31 18,2 230 50 40 23,5 230 50 40 23,5 230 50 27 15,9 115 60 36 21,2 115 60 47 27,7 115 60 47 27,7 115 60 dB(A) 15 20 27 28 18 24 32 33 / Watts rpm °C Hours Hours / 9,0 1 650 -10...+80 60 000 / 25 000 / 12,0 2 100 -10...+70 52 500 / 25 000 / 12,0 2 650 -10...+70 52 500 / 25 000 / 12,0 2 750 -40...+90 52 500 / 15 000 / 8,0 1 850 -10...+80 62 500 / 25 000 / 11,0 2 450 -10...+70 55 000 / 27 500 / 11,0 3 150 -10...+75 55 000 / 25 000 / 11,0 3 250 -40...+95 55 000 / 15 000 The air flow and noise level of fans without external housing depends on the installation conditions. The stated air flow and noise has been measured with an orifice 76.5 mm Ø at a distance of approx. 17 mm from the mounting bracket. Under exceptionally favourable mounting conditions, the air flow of fan series 8000 N is achievable. The noise in the optimal operating range can only be measured for these fans in a specific application. Fan type 8880 TV 8850 TV 8550 TV 8500 TV 8556 TV 8506 TV 8830 TV 8800 TV Lead wires 325 mm long 325 mm long 325 mm long Length “L” AWG 18, TR 64 AWG 18, TR 64 AWG 18 37+1 3 10 R4 3,7 +0,15 ø75,8 0,3 325 +10 6 +1 tin-plated 90° 205 AC centrifugal fans 101 +0,2 Accessories Representatives 70 max. m3/h AC axial fans Series 3900 92 x 92 x 25 mm – Material: Housing: Die-cast aluminium Impeller: Mineral-reinforced plastic PA – Direction of air flow: Exhaust over struts – Direction of rotation: Counter-clockwise, seen on rotor – Connection: Via 2 flat plug 2,8 x 0,5 mm grounding lug for M4 – Mass: 280 g – Note: Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. See page 185 – Possible special versions: (See page 12) - Protection against moisture Air flow Air flow Nominal voltage Frequency Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 at 40 °C at Tmax Curve Nominal data Type 3950 L 3956 L 3950 M 3956 M 3950 3956 3900 L 3906 L 3900 M 3906 M 3900 3906 Subject to alternations m3/h CFM V Hz dB(A) Bel(A) / Watts rpm °C Hours Hours 31 18,2 230 50 31 18,2 230 50 45 26,5 230 50 45 26,5 230 50 59 34,7 230 50 59 34,7 230 50 24 3,8 / 6,0 1 550 -10...+80 70 000 / 27 500 ➀ 24 3,8 / 6,0 1 550 -40...+80 70 000 / 27 500 ➀ 29 4,2 / 6,0 2 150 -10...+80 70 000 / 27 500 ➁ 29 4,2 / 6,0 2 150 -40...+80 70 000 / 27 500 ➁ 35 4,7 / 11,0 2 650 -20...+80 55 000 / 20 000 ➂ 35 4,7 / 11,0 2 650 -40...+80 55 000 / 20 000 ➂ 39 23,0 115 60 39 23,0 115 60 53 31,2 115 60 53 31,2 115 60 70 41,2 115 60 70 41,2 115 60 27 4,0 / 27 4,0 / 34 4,6 / 34 4,6 / 40 5,1 / 40 5,1 / 5,0 1 850 -10...+80 70 000 / 27 500 ➃ 5,0 1 850 -40...+80 70 000 / 27 500 ➃ 5,0 2 600 -10...+80 70 000 / 27 500 ➄ 5,0 2 600 -40...+80 70 000 / 27 500 ➄ 9,0 3 150 -20...+80 60 000 / 22 500 ➅ 9,0 3 150 -40...+80 60 000 / 22 500 ➅ Pa [in H O] 2 60 16 3 50 0,20 0,15 0,10 40 15 30 2 14 20 1 10 0,05 0 10 20 30 CFM 10 20 30 40 50 60 m³/h 50 Hz 60 Hz 206 Guard grilles from p. 238 Connection cables p. 251 Information DC axial fans 89 max. m3/h AC axial fans Series 3000 92 x 92 x 38 mm – Material: Housing: Die-cast aluminium Impeller: Painted sheet steel – Direction of air flow: Exhaust over struts – Direction of rotation: Clockwise, seen on rotor – Connection: Via 2 single wires grounding lug for M4 x 8 – Mass: 420 g – Note: Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. See page 185 – Possible special versions: (See page 12) - Protection against moisture - Protection against salt fog - Type of protection: IP 54 / IP 68 DC centrifugal fans Service life L10 at 40 °C at Tmax Temperature range Air flow Air flow Nominal voltage Frequency Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed DC fans - specials Curve ACmaxx / GreenTech EC-Compact fans AC axial fans Nominal data Type 3850 3856 3550 3556 3650 3656 3800 3806 3500 3506 3600 3606 Subject to alternations m3/h CFM V Hz dB(A) Bel(A) / Watts rpm °C Hours Hours 49 28,8 230 50 54 31,8 230 50 67 39,4 230 50 67 39,4 230 50 75 44,1 230 50 75 44,1 230 50 24 3,7 / 9,0 1 750 -10...+75 60 000 / 27 500 ➀ 26 3,9 / 9,0 1 950 -40...+90 60 000 / 20 000 ➁ 32 4,4 / 8,5 2 300 -10...+80 60 000 / 25 000 ➂ 33 4,5 / 8,5 2 400 -40...+90 60 000 / 20 000 ➂ 36 4,8 / 12,0 2 650 -10...+55 52 500 / 37 500 ➃ 37 4,9 / 12,0 2 700 -40...+75 52 500 / 22 500 ➃ 54 31,8 115 60 60 35,3 115 60 73 43,0 115 60 73 43,0 115 60 89 52,4 115 60 89 52,4 115 60 26 3,9 / 8,0 1 900 -10...+80 62 500 / 25 000 ➄ 29 4,2 / 8,0 2 150 -40...+95 62 500 / 17 500 ➅ 35 4,6 / 8,0 2 500 -10...+80 62 500 / 25 000 ➆ 36 4,7 / 8,0 2 600 -40...+95 62 500 / 17 500 ➆ 41 5,1 / 11,0 3 100 -10...+65 55 000 / 30 000 ➇ 42 5,2 / 11,0 3 200 -40...+75 55 000 / 25 000 ➇ Fan type With sleeve bearings With ball bearings Lead wires 310 mm long 310 mm long Length “L” AWG 18, TR 64 AWG 18 0,25 [in H2O] Pa 70 8 60 4 50 0, 2 0,05 0,10 0,15 40 37 30 26 20 15 10 0 10 20 30 40 10 20 30 40 50 60 70 50 Hz CFM m³/h 60 Hz Guard grilles from p. 238 tin-plated 207 AC centrifugal fans Accessories Representatives max. 135 m3/h AC axial fans Series 9900 119 x 119 x 25 mm – Material: Housing: Die-cast aluminium Impeller: Mineral-reinforced plastic PA – Direction of air flow: Exhaust over struts – Direction of rotation: Counter-clockwise, seen on rotor – Connection: Via 2 flat plug 2,8 x 0,5 mm grounding lug for M4 – Mass: 320 g – Note: Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. See page 188 – Possible special versions: (See page 12) - Protection against moisture Air flow Air flow Nominal voltage Frequency Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 at 40 °C at Tmax Curve Nominal data Type 9956 L 9956 M 9950 9956 9906 L 9906 M 9900 9906 Subject to alternations m3/h CFM V Hz dB(A) Bel(A) / Watts rpm 84 49,4 230 50 104 61,2 230 50 117 68,9 230 50 117 68,9 230 50 29 4,4 / 9,5 1850 35 4,7 / 10,0 2250 37 5,0 / 14,0 2450 37 5,0 / 14,0 2450 100 58,9 115 60 111 65,3 115 60 135 79,5 115 60 135 79,5 115 60 34 4,6 / 8,0 2100 37 5,0 / 8,0 2450 42 5,4 / 12,0 2850 42 5,4 / 12,0 2850 °C -40...+80 -40...+80 -20...+70 -40...+70 -40...+80 -40...+80 -20...+70 -40...+70 Hours Hours 57 500 / 22 500 ➀ 57 500 / 22 500 ➁ 47 500 / 22 500 ➂ 47 500 / 22 500 ➂ 62 500 / 25 000 ➃ 62 500 / 25 000 ➄ 52 500 / 25 000 ➅ 52 500 / 25 000 ➅ [in H O] 2 Pa 3 0,15 40 6 30 5 2 0,10 4 20 1 0,05 10 0 15 30 45 60 20 40 60 80 100 50 Hz CFM m³/h 60 Hz 208 Guard grilles from p. 238 Connection cables p. 251 Information DC axial fans max. 180 m3/h AC axial fans Series 4000 N 119 x 119 x 38 mm – Material: Housing: Die-cast aluminium Impeller: Painted sheet steel – Direction of air flow: Intake over struts Types 4890 N and 4840 N exhaust over struts – Direction of rotation: Clockwise, seen on rotor – Connection: Via 2 single wires grounding lug for M4 and UNC – Mass: 550 g – Note: Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. See page 188 – Optionally available: Variants with strengthened mounting flanges and customizable single strands – Possible special versions: (See page 12) - Speed signal - Protection against moisture - Protection against salt fog - Type of protection: IP 54 / IP 68 DC centrifugal fans Service life L10 at 40 °C at Tmax Temperature range Air flow Air flow Nominal voltage Frequency Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed DC fans - specials Curve ACmaxx / GreenTech EC-Compact fans AC axial fans Nominal data Type 4890 N 4850 N* 4580 N* 4550 N* 4650 N 4656 N 4840 N 4800 N* 4530 N* 4500 N* 4600 N 4606 N Subject to alternations m3/h CFM V Hz dB(A) Bel(A) / Watts rpm °C Hours Hours 80 47 230 50 100 59 230 50 123 72 230 50 145 85 230 50 160 94 230 50 160 94 230 50 25 4,0 / 11,0 1 550 -10...+70 55 000 / 27 500 ➀ 32 4,4 / 10,0 1 800 -10...+70 57 500 / 27 500 ➁ 41 5,2 / 18,0 2 350 -10...+55 40 000 / 27 500 ➂ 44 5,4 / 16,5 2 550 -10...+55 42 500 / 30 000 ➃ 46 5,4 / 19,0 2 650 -10...+55 37 500 / 27 500 ➄ 47 5,5 / 19,0 2 650 -40...+85 37 500 / 15 000 ➄ 85 50 115 60 97 57 115 60 151 89 115 60 169 100 115 60 180 106 115 60 180 106 115 60 26 4,1 / 10,0 1 650 -10...+75 57 500 / 25 000 ➅ 32 4,3 / 9,0 1 750 -10...+75 60 000 / 27 500 ➆ 45 5,4 / 16,0 2 700 -10...+65 42 500 / 25 000 ➇ 48 5,7 / 15,0 3 000 -10...+65 47 500 / 25 000 ➈ 50 5,7 / 18,0 3 100 -10...+60 40 000 / 25 000 ➉ 51 5,8 / 18,0 3 100 -40...+90 40 000 / 15 000 ➉ * Fan with 3 blades. [in H O] 2 Pa Pa [in H2O] 80 5 0, 3 60 4 0, 2 0, 1 40 3 2 20 1 0, 3 10 80 9 60 8 40 0, 2 0, 1 7 20 6 0 20 40 60 80 CFM 25 50 75 100 125 m³/h 60 Hz 0 20 40 60 80 CFM 25 50 75 100 125 m³/h 50 Hz Guard grilles from p. 238 Connection cables p. 251 209 AC centrifugal fans Accessories Representatives max. 180 m3/h AC axial fans Series 4000 Z 119 x 119 x 38 mm – Material: Housing: Die-cast aluminium Impeller: Painted sheet steel – Direction of air flow: Exhaust over struts – Direction of rotation: Clockwise, seen on rotor – Connection: Via 2 flat plug 2,8 x 0,5 mm grounding lug for M4 x 8 – Mass: 540 g – Note: Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. See page 188 – Possible special versions: (See page 12) - Speed signal - Protection against moisture - Protection against salt fog - Type of protection: IP 54 / IP 68 Air flow Air flow Nominal voltage Frequency Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 at 40 °C at Tmax Curve Nominal data Type 4850 Z 4856 Z 4580 Z 4586 Z 4650 Z 4656 Z 4800 Z 4806 Z 4530 Z 4536 Z 4600 Z 4606 Z Subject to alternations m3/h CFM V Hz dB(A) Bel(A) / Watts rpm °C Hours Hours 100 59 230 50 100 59 230 50 115 68 230 50 115 68 230 50 160 94 230 50 160 94 230 50 26 4,0 / 13,0 1 700 -10...+65 50 000 / 27 500 ➀ 26 4,0 / 13,0 1 700 -40...+75 50 000 / 20 000 ➀ 30 4,3 / 13,0 1 900 -10...+65 50 000 / 27 500 ➁ 30 4,3 / 13,0 1 900 -40...+75 50 000 / 20 000 ➁ 40 5,3 / 19,0 2 650 -10...+50 37 500 / 30 000 ➂ 40 5,3 / 19,0 2 650 -40...+75 37 500 / 17 500 ➂ 105 62 115 60 105 62 115 60 120 71 115 60 120 71 115 60 180 106 115 60 180 106 115 60 28 4,1 / 12,0 1 800 -10...+70 52 500 / 25 000 ➃ 28 4,1 / 12,0 1 800 -40...+75 52 500 / 17 500 ➃ 32 4,4 / 12,0 2 000 -10...+70 52 500 / 25 000 ➄ 32 4,4 / 12,0 2 000 -40...+75 52 500 / 17 500 ➄ 45 5,6 / 18,0 3 100 -10...+60 40 000 / 25 000 ➅ 45 5,6 / 18,0 3 100 -40...+85 40 000 / 15 000 ➅ Pa 0,05 0,10 0,15 0,20 0,25 [in H2O] 70 3 6 60 50 40 30 2 5 20 1 4 10 0 20 40 60 80 100 CFM 25 50 75 100 125 150 m³/h 50 Hz 60 Hz 210 Guard grilles from p. 238 Connection cables p. 251 Information max. 140 m3/h AC axial fans Series 4600 TZ Ø 108 x 37 mm – Material: Impeller: Die-cast aluminium – Possible special versions: Mounting bracket: Metal (See page 12) – Direction of air flow: Exhaust over mounting bracket - Protection against moisture – Direction of rotation: Clockwise, seen on rotor - Protection against salt fog – Connection: Via 2 single wires - Type of protection: IP 54 / IP 68 – Mass: 430 g DC axial fans DC centrifugal fans Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 at 40 °C at Tmax Air flow Air flow Nominal voltage Frequency Sound pressure level DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans Nominal data Type 4650 TZ 4656 TZ 4600 TZ 4606 TZ Subject to alternations m3/h CFM V Hz 125 73,6 230 50 125 73,6 230 50 140 82,4 115 60 140 82,4 115 60 dB(A) 42 42 45 45 The air flow and noise level of fans without external housing depends on the installation conditions. The stated air flow and noise has been measured with an orifice 109 mm Ø at a distance of approx. 17 mm from the mounting bracket. Under exceptionally favourable mounting conditions, the air flow of fan series 4000 Z is achievable. The noise in the optimal operating range can only be measured for these fans in a specific application. / Watts rpm °C Hours Hours / 19,0 2 600 -10...+50 37 500 / 30 000 / 19,0 2 600 -40...+65 37 500 / 20 000 / 18,0 2 950 -10...+50 40 000 / 32 500 / 18,0 2 950 -40...+75 40 000 / 17 500 Fan type 4650 TZ 4600 TZ 4656 TZ 4606 TZ Lead wires AWG 22, TR 32 AWG 18 16 37+ 1 3 0,5 + 0,3 R4 4,3 +0,15 ø108 +0,3 148,2 +0,2 tin-plated 90° 211 AC centrifugal fans Accessories 6 +1 375 +10 Representatives max. 206 m3/h AC axial fans Series 5900 127 x 127 x 38 mm – Material: Housing: Die-cast aluminium Impeller: GRP1) (PA) – Direction of air flow: Exhaust over struts – Direction of rotation: Counter-clockwise, seen on rotor – Connection: Via 2 flat plug 2,8 x 0,5 mm grounding lug for M4 x 6 – Mass: 570 g – Possible special versions: (See page 12) - Protection against moisture 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Frequency Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 at 40 °C at Tmax Curve Nominal data Type 5988 5950 5958 5938 5900 5908 Subject to alternations m3/h CFM V Hz dB(A) Bel(A) / Watts rpm °C Hours Hours 150 88 230 50 180 106 230 50 180 106 230 50 37 4,9 / 13,0 2 250 -30...+55 35 000 / 20 000 ➀ 43 5,4 / 18,0 2 700 -20...+50 40 000 / 32 500 ➂ 44 5,5 / 18,0 2 750 -30...+60 40 000 / 25 000 ➂ 162 95 115 60 206 121 115 60 206 121 115 60 40 4,9 / 12,0 2 500 -30...+55 35 000 / 20 000 ➁ 46 5,7 / 17,0 3 050 -20...+55 42 500 / 30 000 ➃ 47 5,8 / 17,0 3 100 -30...+75 42 500 / 20 000 ➃ [in H O] 2 Pa 3 70 0,25 60 4 1 50 0,20 0,15 40 2 30 0,10 20 0,05 10 0 20 40 60 80 100 CFM 25 50 75 100 125 150 m³/h 50 Hz 60 Hz 212 Guard grilles from p. 238 Connection cables p. 251 Information DC axial fans DC centrifugal fans max. 270 m3/h AC axial fans Series 5600 135 x 135 x 38 mm – Material: Housing: Die-cast aluminium Impeller: Painted sheet steel – Direction of air flow: Exhaust over struts – Direction of rotation: Counter-clockwise, seen on rotor – Connection: Via 2 flat plug 2,8 x 0,5 mm grounding lug for M4 x 8 – Mass: 800 g – Possible special versions: (See page 12) - Protection against moisture - Protection against salt fog - Type of protection: IP 54 Service life L10 at 40 °C at Tmax Temperature range Air flow Air flow Nominal voltage Frequency Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Curve Nominal data Type 5656 S 5606 S Subject to alternations m3/h CFM V Hz dB(A) Bel(A) / Watts rpm °C Hours Hours 235 138 230 50 46 5,9 / 30,0 2 700 -35...+70 45 000 / 20 000 ➀ 270 159 115 60 50 6,2 / 26,0 3 100 -35...+80 47 500 / 20 000 ➁ DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Pa [in H2O] Accessories 2 100 1 80 0, 3 60 0, 2 40 0, 1 20 0 40 80 120 CFM 50 100 150 200 250 m³/h 50 Hz 60 Hz Guard grilles from p. 238 Connection cables p. 251 213 Representatives max. 380 m3/h AC axial fans Series 7000 150 x 172 x 38 mm – Material: Housing: Die-cast aluminium Impeller: Painted sheet steel – Direction of air flow: Exhaust over struts – Direction of rotation: Counter-clockwise, seen on rotor – Connection: Via 2 flat plug 2,8 x 0,5 mm grounding lug for M4 x 8 – Mass: 900 g – Note: Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. See page 190, 192, 193 Air flow Air flow Nominal voltage Frequency Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 at 40 °C at Tmax Curve Nominal data Type 7056 ES 7006 ES Subject to alternations m3/h CFM V Hz dB(A) Bel(A) / Watts rpm °C Hours Hours 320 188 230 50 51 6,4 / 27,0 2 800 -25...+55 60 000 / 32 000 ➀ 380 224 115 60 56 6,8 / 28,0 3 350 -25...+65 55 000 / 18 000 ➁ Pa [in H O] 2 0,1 0,2 0,3 0,4 0,5 0,6 2 160 1 120 80 40 0 40 80 120 160 200 CFM 50 100 150 200 250 300 m³/h 50 Hz 60 Hz 214 Guard grilles from p. 238 Connection cables p. 251 Information DC axial fans DC centrifugal fans max. 380 m3/h AC axial fans Series 7800 Ø 150 x 55 mm – Material: Housing: Die-cast aluminium Impeller: Painted sheet steel – Direction of air flow: Exhaust over struts – Direction of rotation: Counter-clockwise, seen on rotor – Connection: Via 2 single wires, wire ends with brass lead tips grounding lug for M4 x 8 – Mass: 1,1 kg – Note: Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. See page 190 Service life L10 at 40 °C at Tmax Temperature range Air flow Air flow Nominal voltage Frequency Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Curve Nominal data Type 7855 ES 7856 ES 7805 ES 7806 ES Subject to alternations m3/h CFM V Hz dB(A) Bel(A) / Watts rpm °C Hours Hours 325 191 230 50 325 191 230 50 49 6,0 / 45,0 2 800 -25...+50 60 000 / 47 500 ➀ 49 6,0 / 45,0 2 800 -25...+70 60 000 / 30 000 ➀ 380 224 115 60 380 224 115 60 53 6,4 / 38,0 3 250 -25...+70 60 000 / 47 500 ➁ 53 6,4 / 38,0 3 250 -25...+90 60 000 / 15 000 ➁ DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans [in H O] 2 Pa Accessories 140 2 0, 5 120 0, 4 100 0, 3 80 1 60 0, 2 40 0, 1 20 0 40 80 120 160 200 CFM 50 100 150 200 250 300 m³/h 50 Hz 60 Hz Guard grilles from p. 238 tin-plated 215 Representatives max. 425 m3/h AC axial fans Series 7400 Ø 150 x 55 mm – Material: Housing: Die-cast aluminium Impeller: Painted sheet steel – Direction of air flow: Exhaust over struts – Direction of rotation: Counter-clockwise, seen on rotor – Connection: Via 2 single wires, wire ends with brass lead tips grounding lug for M4 x 8 – Mass: 1,1 kg – Note: Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. See page 190 Air flow Air flow Nominal voltage Frequency Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 at 40 °C at Tmax Curve Nominal data Type 7450 ES 7400 ES Subject to alternations m3/h CFM V Hz dB(A) Bel(A) / Watts rpm °C Hours Hours 380 224 230 50 60 6,8 / 47,0 2 700 -25...+50 63 000 / 50 000 ➀ 425 250 115 60 62 6,9 / 46,0 3 050 -25...+70 50 000 / 24 000 ➁ Pa [in H O] 2 0, 4 0, 3 120 2 1 100 80 60 40 20 0, 2 0, 1 0 40 80 120 160 200 240 CFM 100 200 300 400 m³/h 50 Hz 60 Hz 216 Guard grilles from p. 238 tin-plated Information DC axial fans DC centrifugal fans max. 500 m3/h AC axial fans Series 6000 Ø 172 x 51 mm – Material: Housing: Die-cast aluminium Impeller: Painted sheet steel – Direction of air flow: Exhaust over struts – Direction of rotation: Counter-clockwise, seen on rotor – Connection: Via 2 flat plug 2,8 x 0,5 mm grounding lug for M4 x 6 – Mass: 1,0 kg – Note: Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. See page 192,193 Service life L10 at 40 °C at Tmax Temperature range Air flow Air flow Nominal voltage Frequency Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Curve Nominal data Type 6058 ES 6078 ES 6008 ES 6028 ES Subject to alternations m3/h CFM V Hz dB(A) Bel(A) / Watts rpm °C Hours Hours 375 221 230 50 420 247 230 50 55 5,9 / 24,0 2 800 -25...+70 62 000 / 31 000 ➀ 54 6,3 / 26,0 2 800 -25...+60 62 000 / 39 000 ➁ 440 259 115 60 500 284 115 60 60 6,4 / 26,0 3 300 -25...+70 57 000 / 28 000 ➂ 58 6,7 / 29,0 3 300 -25...+75 57 000 / 22 000 ➃ DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Pa [in H O] 2 Accessories 160 0,1 0,2 0,3 0,4 0 ,5 0,6 120 80 40 1 23 4 0 40 80 120 160 200 240 CFM 100 200 300 400 m³/h 50 Hz 60 Hz Guard grilles from p. 238 217 Representatives max. 1030 m3/h AC axial fans 225 x 225 x 80 mm – Material: Housing: Die-cast aluminium Impeller: Sheet steel – Number of blades: 7 – Direction of air flow: Exhaust over struts – Direction of rotation: Counter-clockwise, seen on rotor – Type of protection: IP44, depending on installation and position – Insulation class: "B" – Mounting position: Any – Connection: Terminal strips (operating capacitor connected) – Mass: 2,0 kg – Operation mode: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Air flow Air flow Nominal voltage Frequency Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Speed / rpm Perm. amb. temp. Service life L10 at 40 °C at Tmax Curve Nominal data Type m3/h CFM V Hz W2E 200-HK86-01 1030 606 115 60 W2E 200-HK38-01 Subject to alternations 880 518 230 50 dB(A) Bel(A) / 61 6,7 / 58 6,6 / Watts rpm 80,0 2800 64,0 2550 °C -25...+65 -25...+60 Hours Hours 60 000 / 58 000 ➀ 63 000 / 60 000 ➀ 218 Guard grilles from p. 238 Inlet nozzles from p. 248 Connection cables p. 251 Information DC axial fans max. 1865 m3/h AC axial fans 280 x 280 x 80 mm – Material: Housing: Die-cast aluminium Impeller: Sheet steel – Number of blades: 7 – Direction of air flow: Exhaust over struts – Direction of rotation: Counter-clockwise, seen on rotor – Type of protection: IP44, depending on installation and position – Insulation class: "F" – Mounting position: Any – Connection: Terminal strips (operating capacitor connected) – Mass: 2,0 kg – Operation mode: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Service life L10 at 40 °C at Tmax Perm. amb. temp. Air flow Air flow Nominal voltage Frequency Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Speed / rpm Nominal data Type W2E 250-HL06-01 Subject to alternations m3/h CFM V Hz 1865 1077 230 50 dB(A) Bel(A) / 66 7,2 / Watts 127,0 rpm 2 550 °C -25...+60 Hours Hours 63 000 / 70 000 ➀ DC centrifugal fans DC fans - specials Curve ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Representatives Guard grilles from p. 238 Inlet nozzles from p. 248 Connection cables p. 251 219 max. 850 m3/h AC diagonal module Ø 200 mm – Material: – Number of blades: – Direction of air flow: – Direction of rotation: – Type of protection: – Insulation class: – Mounting position: – Condensate discharges: – Operation mode: – Bearings: Housing: Plastic PA Support bracket: Plastic PA Impeller: Plastic PA Rotor: Coated in black 7 "V" Clockwise, seen on rotor IP 44, depending on installation and position "F" Any None Continuous operation (S1) Maintenance-free ball bearings Curve Nominal voltage Frequency Air flow Speed / rpm Input power Input current Capacitor Sound pressure level Max. back-pressure Perm. amb. temp. Mass Electrical connection Nominal data Type K2E 200-AA12 -01 Subject to alternations Motor M2E 068-CF VAC Hz A 1~ 115 50 B 1~ 115 60 m3/h rpm 765 2650 840 2910 W A μF/VDB dB(A) Pa °C kg 64 0,56 6,0/250 64 200 -25..+65 2,1 88 0,77 6,0/250 64 240 -25..+65 2,1 p. 259 / A1) Curve: 50 Hz B 60 Hz A n Ped rpm W I LWA A dB(A) A 1 2650 64 0,56 --- A 2 2610 67 0,59 --- A 3 2580 70 0,61 --- A 4 2590 69 0,61 --- B 1 2910 88 0,77 72 B 2 2815 93 0,81 69 B 3 2755 96 0,84 69 B 4 2780 95 0,83 71 220 Air performance measured as per: ISO 5801, Installation category A, without protection against accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted! For detailed information see http://www.ebmpapst.com/general conditions Information DC axial fans – Motor protection: – Touch current: – Cable exit: – Electrical connection – Protection class: – Product conforming to standards: – Approvals: TOP wired internally < 0,75 mA acc. to IEC 60990 (test circuit, illustration 4) Lateral Via connector I (if customer has provided connection for protective earth) EN 60335-1, CE UL 2111, CSA C22.2 Nr. 77 DC centrifugal fans DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans X Mounting dimensions Coded plug system Universal-Mate-N-Lok Connector shell: AMP 350 780-1 3 x Pin connector: AMP 926 885-1 Mating connector (not part of delivery): Connector shell: AMP 350 779-4 3 x female terminal: AMP 926 884-1 View X 1 2 34 1 = not used 2 = N + condensator 3=L 4 = PE Guard grilles from p. 238 Electrical connections p. 259 221 Accessories Representatives max. 850 m3/h AC diagonal module Ø 200 mm – Material: – Number of blades: – Direction of air flow: – Direction of rotation: – Type of protection: – Insulation class: – Mounting position: – Condensate discharges: – Operation mode: – Bearings: Housing: Plastic PA Support bracket: Plastic PA Impeller: Plastic PA Rotor: Coated in black 7 "V" Clockwise, seen on rotor IP 44, depending on installation and position "F" Any None Continuous operation (S1) Maintenance-free ball bearings Curve Nominal voltage Frequency Air flow Speed / rpm Input power Input current Capacitor Sound pressure level Max. back-pressure Perm. amb. temp. Mass Electrical connection Nominal data Type K2E 200-AA52 -02 Subject to alternations Motor M2E 068-CF VAC Hz A 1~ 230 50 B 1~ 230 60 m3/h rpm 765 2650 850 2950 W A μF/VDB dB(A) Pa °C kg 65 0,30 2,0/400 62 200 -25..+75 2,1 90 0,40 2,0/400 62 245 -25..+75 2,1 p. 259 / A1) Curve: 50 Hz B 60 Hz A n Ped rpm W I LWA A dB(A) A 1 2650 65 0,30 70 A 2 2620 67 0,30 68 A 3 2605 68 0,30 67 A 4 2610 68 0,30 69 B 1 2950 90 0,40 73 B 2 2865 93 0,41 70 B 3 2820 96 0,42 69 B 4 2840 94 0,41 71 222 Air performance measured as per: ISO 5801, Installation category A, without protection against accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted! For detailed information see http://www.ebmpapst.com/general conditions Information DC axial fans – Motor protection: – Touch current: – Cable exit: – Electrical connection – Protection class: – Product conforming to standards: – Approvals: TOP wired internally < 0,75 mA acc. to IEC 60990 (test circuit, illustration 4) Lateral Via connector I (if customer has provided connection for protective earth) EN 60335-1, CE UL 2111, CSA C22.2 Nr. 77 DC centrifugal fans DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans X Mounting dimensions Coded plug system Universal-Mate-N-Lok Connector shell: AMP 350 780-1 3 x Pin connector: AMP 926 885-1 Mating connector (not part of delivery): Connector shell: AMP 350 779-4 3 x female terminal: AMP 926 884-1 View X 1 2 34 1 = not used 2 = N + condensator 3=L 4 = PE Guard grilles from p. 238 Electrical connections p. 259 223 Accessories Representatives max. 880 m3/h AC diagonal module Ø 200 mm – Material: – Number of blades: – Direction of air flow: – Direction of rotation: – Type of protection: – Insulation class: – Mounting position: – Condensate discharges: – Operation mode: – Bearings: Housing: Plastic PA Support bracket: Plastic PA Impeller: Plastic PA Rotor: Coated in black 7 "V" Clockwise, seen on rotor IP 44, depending on installation and position "F" Any None Continuous operation (S1) Maintenance-free ball bearings Curve Nominal voltage Frequency Air flow Speed / rpm Input power Input current Capacitor Sound pressure level Max. back-pressure Perm. amb. temp. Mass Electrical connection Nominal data Type K2D 200-AA02 -02 Subject to alternations Motor M2D 068-CF VAC Hz A 3~ 400 Y 50 B 3~ 400 Y 60 m3/h rpm 780 2700 880 3050 W A μF/VDB dB(A) Pa °C kg 65 0,15 --90 0,16 --- 62 210 -25..+75 2,0 65 260 -25..+75 2,0 p. 259 / C2) Curve: B 50 Hz 60 Hz A n Ped rpm W I LWA A dB(A) A 1 2700 65 0,15 71 A 2 2695 69 0,16 69 A 3 2675 71 0,16 68 A 4 2680 70 0,16 69 B 1 3050 90 0,16 73 B 2 3010 94 0,16 71 B 3 2970 98 0,17 70 B 4 2975 96 0,17 72 224 Air performance measured as per: ISO 5801, Installation category A, without protection against accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted! For detailed information see http://www.ebmpapst.com/general conditions Information DC axial fans – Motor protection: – Touch current: – Cable exit: – Electrical connection – Protection class: – Product conforming to standards: TOP wired internally < 0,75 mA acc. to IEC 60990 (test circuit, illustration 4) Lateral Via connector I (if customer has provided connection for protective earth) EN 60335-1, CE DC centrifugal fans DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans X Mounting dimensions Coded plug system Universal-Mate-N-Lok Connector shell: AMP 350 780-1 3 x Pin connector: AMP 926 885-1 Mating connector (not part of delivery): Connector shell: AMP 350 779-4 3 x female terminal: AMP 926 884-1 View X 1 2 34 1 = L3 2 = L1 3 = L2 4 = PE Guard grilles from p. 238 Electrical connections p. 259 225 Accessories Representatives 226 227 Representatives Accessories AC centrifugal fans AC axial fans ACmaxx / GreenTech EC-Compact fans DC fans - specials DC centrifugal fans DC axial fans 230 AC centrifugal fans 229 AC centrifugal fan overview AC centrifugal fans Information AC centrifugal fans Technical information Product line The renowned ebm-papst AC fans are used when DC voltage is not available. The AC range of fans is based on experience gained from decades of development activity, millions of units in series production and competence in innovation of a world-wide technological leader. A wide range of fans for AC operation is presented in this catalogue. In addition to complete device fans, you will also find fans without external housing, providing a particularly economical advantage when the air duct can be integrated in the respective device. Variety of sizes AC fans are available in a variety of sizes with either air exhaust or air intake over struts. Silent running models with sleeve bearings (or for extreme ambient conditions) fans with ball bearings are available. Electrical connection with plug connection or external leads are available. Shaded-pole or capacitor motors Fan drives by shaded-pole or capacitor motors, most of which incorporate the world-famous ebm-papst external rotor principle: The fan blades are directly attached to the external rotor of the external rotor motor, thus combining both high performance and profitability. Bearings AC fans with sleeve bearings are powered by Class E insulated motors. Fans with ball bearings are equipped with Class B, E or F insulated motors. Type of protection All ebm-papst fans conform to the requirements of IP 20. Fans conforming to IP 54 / IP 68 and special types of protection are also available. AC voltage The line of AC fans for Euro voltage according to IEC 60038 (230 V ± 10 %) is basically also available for 115 V. Frequencies AC fans can be operated at frequencies of 50 Hz or 60 Hz. However, their technical data then change accordingly. Capacitor Fans driven by capacitor external motors provide particularly high operating efficiency. Generally, the required operating capacitor is already integrated in the fan housing. Flat built AC fans ebm-papst also has particularly flat built AC fans with internal rotor motor. Their advantage: quick start to full speed. A plastic impeller and the both smaller and lighter internal rotor motor lead to a lower moment of inertia. Overloading Almost all AC fans are protected against overloading (e.g. due to locked rotor) the drive motors are either impedance protected (marked “Impedance protected”, and/or “Z.P.”) or are equipped with a thermal switch (marked “Thermally protected” or “Th.P.”). The model designation of these fans ends with “S”. 228 Information DC axial fans DC centrifugal fans Centrifugal fans for AC operation Overview of air performance Dimension Series Air flow Page mm c 121 x 37 c 135 x 38 c 180 x 40 c 220 x 56 Ø 138 x 40 Ø 176 x 54 RL 90 RG 90 RG 125 RG 160 RER 125 RER 160 Subject to alternations m3/h 10 40...42 47...54 86...94 202...223 104...115 234...274 20 30 40 50 60 70 80 90 100 200 300 400 500 600 700 800 900 1000 2000 3000 230 231 232 233 234 235 Overview of technically feasible designs protection Salt fog Page IP >= IP 68 IHPu>mi=diItPy5pr4otection Speed signal VDE, UL, CSA bSianltlecbeslaereivnegbsearings/ Dimension Centrifugal fans Series mm RL 90 121 x 121 x 37 ja RG 90 135 x 135 x 38 ja RG 125 180 x 180 x 40 ja RG 160 220 x 220 x 56 ja RER 125 138 Ø x 40 ja RER 160 176 Ø x 54 ja Subject to alternations • availabe – not yet available OPTIONAL p. / – • • – • 230 / – • • – • 231 – • • – • 232 – • • – • 233 – • • – • 234 – • • – • 235 Sleeve bearings Ball bearings DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Representatives 229 42 max. m3/h AC centrifugal fans Series RL 90 121 x 121 x 37 mm – Material: Spiral housing: GRP1) (PBT) Impeller: GRP1) (PA) Housing base: Steel plate – Direction of air flow: Centrifugal: Air outlet via window in housing – Direction of rotation: Clockwise, seen on rotor – Connection: Via 2 single wires; housing base with flat plugs 6,3 x 0,8 mm for protective earth conductor – Highlights: forwards-curved impeller – Mass: 680 g 1) Fibreglass-reinforced plastic – Possible special versions: (See page 12) - Protection against moisture - Protection against salt fog - Type of protection: IP 54 Air flow Air flow Nominal voltage Frequency Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 at 40 °C at Tmax Curve Nominal data Type RL 90-18/50 RL 90-18/56 RL 90-18/00 RL 90-18/06 Subject to alternations m3/h CFM V Hz 40 23,5 230 50 40 23,5 230 50 42 24,7 115 60 42 24,7 115 60 Bel(A) 5,6 5,6 6,0 6,0 / Watts rpm / 20,0 2 450 / 20,0 2 450 / 19,5 2 550 / 19,5 2 550 °C Hours Hours -10...+50 37 500 / 30 000 ➀ -30...+70 37 500 / 20 000 ➀ -10...+60 37 500 / 25 000 ➁ -30...+85 37 500 / 15 000 ➁ Fan type RL 90-18/50 RL 90-18/56 RL 90-18/00 RL 90-18/06 Lead wires AWG 18, TR 32 AWG 22 Pa [in H O] 2 0, 4 0, 3 2 120 100 1 80 60 40 20 0, 2 0, 1 0 4 8 12 16 20 CFM 5 10 15 20 25 30 m³/h 50 Hz 60 Hz 230 tin-plated Information DC axial fans DC centrifugal fans 54 max. m3/h AC centrifugal fans Series RG 90 135 x 135 x 38 mm – Material: Spiral housing: GRP1) (PBT) Impeller: GRP1) (PA) Housing base: Steel plate – Direction of air flow: Centrifugal: Air outlet via window in housing – Direction of rotation: Clockwise, seen on rotor – Connection: Via 2 single wires AWG 22 – Highlights: forwards-curved impeller – Mass: 560 g – Possible special versions: (See page 12) - Protection against moisture - Protection against salt fog - Type of protection: IP 54 1) Fibreglass-reinforced plastic Service life L10 at 40 °C at Tmax Temperature range Sintec sleeve bearings Ball bearings Input power Nominal speed Air flow Air flow Nominal voltage Frequency Sound power level Curve Nominal data Type RG 90-18/50 RG 90-18/56 RG 90-18/00 RG 90-18/06 Subject to alternations m3/h CFM V Hz 54 32 230 50 54 32 230 50 47 28 115 60 47 28 115 60 Bel(A) 5,8 5,8 6,2 6,2 / Watts rpm / 22,0 2 200 / 22,0 2 200 / 22,0 1 900 / 22,0 1 900 °C Hours Hours -30...+60 35 000 / 22 500 ➀ -30...+60 35 000 / 22 500 ➀ -30...+65 35 000 / 20 000 ➁ -30...+65 35 000 / 20 000 ➁ DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Pa [in H O] 2 Accessories 0, 4 0, 3 2 120 100 1 80 60 40 20 0, 2 0, 1 0 5 10 15 20 25 30 CFM 10 20 30 40 50 m³/h 50 Hz 60 Hz Guard grilles from p. 238 tin-plated 231 Representatives 94 max. m3/h AC centrifugal fans Series RG 125 180 x 180 x 40 mm – Material: Spiral housing: GRP1) (PBT) Impeller: GRP1) (PA) Housing base: Steel plate – Direction of air flow: Centrifugal: Air outlet via window in housing – Direction of rotation: Clockwise, seen on rotor – Connection: Via 2 single wires AWG 22 – Highlights: backwards-curved impeller – Mass: 850 g – Possible special versions: (See page 12) - Protection against moisture - Protection against salt fog - Type of protection: IP 54 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Frequency Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 at 40 °C at Tmax Curve Nominal data Type RG 125-19/56 RG 125-19/06 Subject to alternations m3/h CFM V Hz 86 51 230 50 94 55 115 60 Bel(A) 5,8 6,0 / Watts rpm / 20,0 2 550 / 19,0 2 750 °C Hours Hours -30...+70 37 500 / 20 000 ➀ -30...+80 40 000 / 15 000 ➁ Pa [in H2O] 0, 6 2 200 1 150 100 50 0, 4 0, 2 0 10 20 30 40 5 0 CFM 20 40 60 80 m³/h 50 Hz 60 Hz 232 Guard grilles from p. 238 tin-plated Information DC axial fans DC centrifugal fans max. 223 m3/h AC centrifugal fans Series RG 160 220 x 220 x 56 mm – Material: Spiral housing: GRP1) (PBT) Impeller: GRP1) (PA) Housing base: Steel plate – Direction of air flow: Centrifugal: Air outlet via window in housing – Direction of rotation: Counter-clockwise, seen on rotor – Connection: Via 2 single wires AWG 18 – Highlights: backwards-curved impeller – Mass: 1,7 kg – Possible special versions: (See page 12) - Protection against moisture 1) Fibreglass-reinforced plastic Service life L10 at 40 °C at Tmax Temperature range Sintec sleeve bearings Ball bearings Input power Nominal speed Air flow Air flow Nominal voltage Frequency Sound power level Curve Nominal data Type RG 160-28/56S RG 160-28/06S Subject to alternations m3/h CFM V Hz 202 119 230 50 223 131 115 60 Bel(A) 6,6 6,9 / Watts rpm / 47,0 2 750 / 50,0 3 050 °C Hours Hours -30...+70 30 000 / 15 000 ➀ -30...+80 27 500 / 12 500 ➁ DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Pa [in H2O] Accessories 2 400 300 1 1, 2 0, 8 200 100 0, 4 0 20 40 60 80 100 120 CFM 50 100 150 200 m³/h 50 Hz 60 Hz Guard grilles from p. 238 tin-plated 233 Representatives max. 115 m3/h AC centrifugal fans Series RER 125 138 Ø x 40 mm – Material: Spiral housing: GRP1) (PBT) Impeller: GRP1) (PA) with steel plate reinforced – Direction of air flow: centrifugal – Direction of rotation: Clockwise, seen on rotor – Connection: Via 2 single wires AWG 22 – Highlights: backwards-curved impeller – Mass: 500 g – Possible special versions: (See page 12) - Protection against moisture - Protection against salt fog - Type of protection: IP 54 1) Fibreglass-reinforced plastic Air flow Air flow Nominal voltage Frequency Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 at 40 °C at Tmax Curve Nominal data Type RER 125-19/56 RER 125-19/06 Subject to alternations m3/h CFM V Hz 104 61 230 50 115 68 115 60 Bel(A) 6,2 6,5 / Watts rpm / 19,0 2 600 / 18,0 2 850 °C Hours Hours -30...+60 37 500 / 22 500 ➀ -30...+70 40 000 / 20 000 ➁ The air flow and noise level of fans without external housing depend on the installation conditions. The stated air flow and noise levels have been measured under the following conditions: Centrifugal fan mounted on a base plate 220 x 220 mm. Cover plate 220 x 220 mm with an air inlet of Ø 86 mm, concentric to the impeller. Pa [in H O] 2 0, 3 2 100 1 80 60 40 20 0, 2 0, 1 0 10 20 30 40 50 6 0 CFM 20 40 60 80 100 m³/h 50 Hz 60 Hz 234 Guard grilles from p. 238 Inlet nozzles from p. 248 tin-plated Information DC axial fans DC centrifugal fans max. 274 m3/h AC centrifugal fans Series RER 160 176 Ø x 54 mm – Material: Spiral housing: GRP1) (PBT) Impeller: GRP1) (PA) with steel plate reinforced – Direction of air flow: centrifugal – Direction of rotation: Counter-clockwise, seen on rotor – Connection: Via 2 single wires AWG 18 – Highlights: backwards-curved impeller – Mass: 1,0 kg – Possible special versions: (See page 12) - Protection against moisture 1) Fibreglass-reinforced plastic Service life L10 at 40 °C at Tmax Temperature range Sintec sleeve bearings Ball bearings Input power Nominal speed Air flow Air flow Nominal voltage Frequency Sound power level Curve Nominal data Type RER 160-28/56S RER 160-28/06S Subject to alternations m3/h CFM V Hz 234 138 230 50 274 161 115 60 Bel(A) 6,6 6,8 / Watts rpm / 45,0 2 800 / 46,0 3 250 °C Hours Hours -30...+60 30 000 / 20 000 ➀ -30...+70 30 000 / 15 000 ➁ The air flow and noise level of fans without external housing depend on the installation conditions. The stated air flow and noise levels have been measured under the following conditions: Centrifugal fan mounted on a base plate 260 x 260 mm. Cover plate 260 x 260 mm with an air inlet of Ø 100 mm, concentric to the impeller. DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Pa [in H2O] Accessories 0, 8 2 250 1 200 150 100 50 0, 6 0, 4 0, 2 0 30 60 90 120 150 CFM 50 100 150 200 250 m³/h 50 Hz 60 Hz Guard grilles from p. 238 Inlet nozzles from p. 248 tin-plated 235 Representatives 236 Information DC axial fans Accessories Guard grilles 238 Fan filter guard grilles 246 Inlet nozzles 248 Connection cables / Accessories 251 Electrical connections 254 DC centrifugal fans DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Everything that you need for your fan. ebm-papst provides an extensive range of accessories for optimum fan operation: From temperature sensing for speed-controlled fans to finger guards of all types, connecting cable, filter, screens, spacers and assembly parts. In addition to the accessories and assembly parts listed in this catalogue, ebm-papst also supplies numerous special parts for fan operation. The sales experts at ebm-papst will be happy to assist you in your enquiries concerning fan assembly and application. From selection to accessories: Insist on the efficient and reliable service provided by ebm-papst. 237 Representatives Guard grilles – Material: Zinc-plated or nickel-plated steel wire – Note: Safety grille in line with DIN EN ISO 13857 (previously EN 294). Additional safety grilles that do not meet DIN EN ISO 13857 can be delivered on request. Our safety grilles are designed specifically for use with ebm-papst fans. They combine the highest degree of safety with minimum effect on operating noise. Please note that safety-relevant clearances cannot be guaranteed when using safety grilles from other manufacturers. Fan series 400 420 J 500 600 3000 8000 9000 4000 Guard grilles LZ29-1 LZ29-1 LZ31 LZ28-1 LZ23-1 LZ32-4 / LZ22-2 LZ30-4 / LZ 30 / LZ 30-3 LZ30-4 / LZ 30 / LZ 30-3 Fan series 5100 5600 5200 5300 5900 7000 6300 6400 Guard grilles LZ25 LZ25 LZ35 LZ53 LZ35 LZ36 LZ37 LZ38 Fan series 2200 F DV 4100 DV 5200 DV 6300 DV 6300 DV 6400 DV 6400 Subject to alternations Guard grilles LZ22 LZ30-4 Intake-/Outlet side LZ35 Intake-/Outlet side LZ37 Intake side LZ52 Outlet side LZ38 Intake side LZ39 Outlet side LZ29-1 Fan size 40 x 40 LZ31 42 42 4,5 50 Fan size 50 x 50 1,8 4,8 LZ28-1 50 Fan size 60 x 60 30+1 59 2 +0,3 4,2±0,5 4,2+0,5 LZ22-2 Fan size 80 x 80 LZ32-4 71,5 Fan size 80 x 80 LZ23-1 82,5 Fan size 92 x 92 105,5 +0,5 48±1 78±1 71,5 82,5 4,3+0,2 2,5+0,3 40+1 78,2 ±0,5 2 + 0,3 4,3+0,2 4,7+1 40+1 92 _1 2 + 0,3 4,3+0,24,7+1 238 Information DC axial fans 153,5 ±1 115 ±1 DC centrifugal fans LZ30 Fan size 119 x 119 LZ30-3 Fan size 119 x 119 LZ30-4 Fan size 119 x 119 104,8 104,8 LZ35 4,3+0,2 3±0,25 5+1 Fan size 127 x 127 LZ25 51,5+1 119 _1 2+0,3 4,3+0,2 4,7+1 Fan size 135 x 135 LZ53 Fan size 140 x 140 124,5 + 0,2 136,5 70 + 0,2 5 LZ36 Fan size 150 x 172 LZ37 Fan size 172 x 51 LZ38 6,45 + 1 Fan size 172 x 51 DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories LZ39 Fan size 172 x 51 LZ52 Fan size 172 x 51 LZ22 Fan size 200 x 51 148,5 199,5 + 0,5 ( 186,5 ) 5 + 0,2 27,5 8,45 + 1 239 Representatives Guard grilles – Material: Zinc-plated or nickel-plated steel wire – Note: Safety grille in line with DIN EN ISO 13857 (previously EN 294). The safety grilles detailed on this page are intended specifically for the ACmaxx / GreenTech EC compact fan ranges and are mounted on the pressure side. Fan series AC 8300 AC 8300 H AC 3200 J AC 3200 J AC 4400 FN AC 4400 FN AC 4300 AC 4300 Guard grilles LZ32-4 Intake side LZ32-7 Outlet side LZ23-1 Intake side LZ23-6 Outlet side LZ30-4 Intake side LZ30-9 Outlet side LZ30-4 Intake side LZ30-9 Outlet side Fan series Guard grilles ACi 4400 LZ30 Intake side ACi 4400 LZ30 Outlet side AC 6200 N LZ37 Intake side AC 6200 N LZ37-2 Outlet side AC 6100 N LZ37 Intake side AC 6100 N * Outlet side * Outlet-side grilles on request LZ30-9 Fan size 119 X 119 LZ37-2 104,8 162 ±0,3 51,5 +0,5 104,8 51,5+1 119 -1 2 +0,3 4,3+0,2 4,7+1 LZ32-7 Fan size 80 x 80 71,5 + 0,2 Fan size Ø 172 X 51 LZ23-6 Fan size 92 x 92 82,5 + 0,2 89 63,7 Ø158,9 2,5 4,5 + 0,1 7,3 4,3 ±0,2 6 ±0,5 79,8 0,5 61,1 + 0,25 4,5 + 0,1 6,3 + 0,3 12,9 + 0,3 240 Information DC axial fans DC centrifugal fans Guard grilles – Material: Steel wire, plastic-coated, silver-metallic gloss Fan series W1G 200 W2E 200 Guard grilles 78128-2-4039 78128-2-4039 Fan series W1G 250 W2E 250 Guard grilles 09418-2-4039 09418-2-4039 78128-2-4039 Size 200 09418-2-4039 Size 250 DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Representatives 241 Guard grilles – Material: Steel wire Guard grilles for centrifugal blowers with dual inlet Part no. Size a b c 83319-2-4039 09485-2-4039 09500-2-4039 Subject to alternations 097 (1) 097 (2) 133 / 146 (1) for D2E097-CH 96,0 114,0 145,0 3,5 71,0 3,5 88,0 4,0 122,0 (2) for D2E097-B* Coating phosphated, plastic-coated in RAL no. 9005 phosphated, plastic-coated in RAL no. 9005 phosphated, plastic-coated in RAL no. 9005 – Material: Phosphated steel wire, plasticcoated, silver-metallic gloss Guard grilles for centrifugal blowers with dual inlet (versions with EW motor) Part no. Size a b c d e 35000-2-4039 160 Subject to alternations 182,0 12,0 144,0 2,4 4,5 242 Information DC axial fans DC centrifugal fans Guard grilles – Material: Welded grille made of galvanised steel, frame made of tinned sheet iron 0.4 mm thick Guard grilles for centrifugal blowers with single inlet Part no. Size a b c 09489-2-4039 09490-2-4039 09494-2-4039 09492-2-4039 09503-2-4039 Subject to alternations 085 (3) 108 120 140 / 146 160 (4) 90,0 126,0 140,0 168,0 183,0 74,0 110,0 124,0 152,0 170,0 (3) 3 drilled holes staggered by 120° 84,0 118,0 132,0 158,0 175,0 (4) Size 160 – Material: steel wire DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Guard grilles for centrifugal blowers with single inlet Part no. Size a b c d e Coating 09603-2-4039 98214-2-4039 25028-2-4039 17729-2-4039 Subject to alternations 076 / 085 108 140 / 146 160 101,0 6,0 79,0 4,3 8,0 plastic coated, silver-metallic gloss 120,0 3,5 88,0 4,3 8,0 plastic coated, silver-metallic gloss 162,0 8,5 139,0 4,3 8,0 galvanised, chromatised in blue 175,0 3,5 139,0 4,6 7,0 galvanised, chromatised in blue 243 Representatives Guard grilles – Material: Fibreglass-reinforced plastic – Note: Guard grille acc. to DIN EN ISO 13857 (previously EN 294). Plastic grilles must not be used for the following models: 8200 JH3 / JH4 3200 JH3 / JH4 4100 NH5 - NH8 Guard grilles Mounting B C D E LZ28-3 A3 60-0,5 50,0±0,2 3,0 24 LZ32-2 A1 LZ32-3 A3 80-0,5 71,5±0,2 7,0 34 80-0,5 71,5±0,2 7,0 34 LZ23-2 A1 LZ23-3 A3 92,5-0,5 82,5±0,2 6,5 46 92,5-0,5 82,5±0,2 6,5 46 Guard grilles Mounting LZ30-5 A2 LZ30-6 A4 LZ33-1 A2 LZ33-2 A4 Subject to alternations B 119-0,5 119-0,5 127-0,5 127-0,5 C 105±0,2 105±0,2 113,5±0,2 113,5±0,2 D E 6,5 50 6,5 50 6,5 50 6,5 50 LZ28-3 LZ32-2 / LZ32-3 LZ23-2 / LZ23-3 LZ30-5 / LZ30-6 LZ33-1 / LZ33-2 Size 60 x 60 Size 80 x 80 Size 92 x 92 Size 119 x 119 Size127 x 127 LZ28-3 Fan size 60 x 60 LZ32P Only suitable for bore hole diameter ¯ 4,3 - ¯ 4,7. Fan size 80 x 80 LZ30P Fan size 119 x 119 244 Information DC axial fans Guard grilles for compact centrifugal modules – Material: Fibreglass-reinforced plastic PA – Highlights: Flame protection class in line with UL 94V-0 Fan series RG 175/190 RG 220 RG 225 Subject to alternations Guard grilles a b LZ46-1 133 9,0 LZ47-1 166 8,7 LZ48-1 158 8,7 DC centrifugal fans DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Representatives 245 Fan filter guard grilles – Material: Filter guard LZ40 N: black, fibreglass-reinforced plastic with inserted wire mesh LZ60. Filter LZ60: stainless steel wire mesh Mounting lug LZ40-1 for mounting Fan series DC 4400 F 4400 FN 4300 4300 N 4400 4200 4100 N Fan series AC AC 4300 9900 4000 N 4000 Z Subject to alternations LZ40N Panel LZ40-1 Mounting lug LZ60 Coarse filter 246 Information DC axial fans DC centrifugal fans Fan filter guard grilles – Material: Grille cover: polycarbonate (PC) with matt finish Mounting plate: wire mesh with black powder coating Filter pad: white, synthetically joined fibres – Note: Filter safety grille suitable for fitting on axial fan ranges in the following dimensions: 60 mm, 80 mm, 92 mm, 119 mm, ø 172 mm. All filter units fit directly on the mounting holes on the fans. Filter safety grille consisting of 3 parts: outer grille cover, inner mounting plate and replaceable filter pad. The filter pad can be replaced quickly and easily via a quick release on the grille cover. The filter pads can be replaced even while the fan is running, as protection is provided by the welded wire mesh. Protection filter FF60 FF80 FF92 FF119 FF172 Subject to alternations Fan size 60 x 60 mm 80 x 80 mm 92 x 92 mm 119 x 119 mm ø 172 mm A B C D 65 65 13,5 50,0 85 85 14,0 71,5 125 105 17,5 82,5 162 136 18,5 104,5 226 190 19,5 162,0 Replacement filter* RF 60 RF 80 RF 92 RF 119 RF 172 * Replacement filters only in packs of 5 pcs. FF60 / FF80 Fan size: 60 x 60 mm 80 x 80 mm FF92 / FF 119 Fan size: 92 x 92 mm 119 x 119 mm A C D A C D DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans D B D B AC centrifugal fans Accessories FF 172 Fan size: Ø 172 mm Filter performance The filter safety grille filters filter 75% of dust particles with a size of 5-10 microns and can withstand temperatures of up to 100 °C. Filter class G3 in line with DIN EN 779. Flame-retardant in line with DIN 53438, class F1. With a clean mounted filter, a reduction of air flow of 20-30% is possible. B A C D 247 Representatives Inlet nozzles for centrifugal fans – Material: Galvanised sheet steel Fan Vers. k m o RET 97 (S) 1 116,0 80,0 10,0 RER 120 (P) 1 146,0 94,4 18,0 RER 133 (P) 1 129,0 87,0 13,0 RER 160 (S) 1 142,0 100,0 9,0 RER 175 / 190 (P) 1 170,0 125,5 14,0 RER 220 (P) 2 252,0 155,0 21,0 RER 225 (P) 1 223,0 146,0 28,0 (P) = plastic, (S) = sheet steel q r1 0,80 10,0 0,80 16,0 1,00 8,0 1,00 8,0 1,25 10,0 0,80 22,0 1,50 25,0 s 108,0 134,0 118,0 132,0 158,0 – 210,0 t 3x4,5 4x4,5 4x4,5 4x4,5 4x4,5 – 4x4,5 u – 126,0 103,0 – 146,0 199,0 196,0 No.: LZ 1000-097 LZ 1000-120 LZ 1000-133 LZ 1000-160 LZ 1000-175 LZ 1000-220 LZ 1000-225 Vers. 1 Vers. 2 118 45° 0 4,3 242 r1 q t 6 x 60° 5,5 Øm Øk Øu Øs 245 4 x 90° 248 Information Inlet nozzles for centrifugal fans Vers. 1 – Material: Galvanised sheet steel DC axial fans DC centrifugal fans DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans Inlet nozzles for backward curved centrifugal fans Part no. Size(1) Vers. k m n o q r1 r2 96120-2-4013 Subject to alternations 120 (P) 1 146,0 94,4 — 18,0 (1) Size with key for impeller material: (P) = plastic, (S) = sheet steel, (A) = aluminium 0,80 16,0 — r3 s t u — 134,0 4x4,5 126,0 Vers. 1 – Material: Galvanised sheet steel Inlet nozzles for forward curved centrifugal fans Part no. Size Vers. a b c d e f r u 09560-2-4013 09563-2-4013 09566-2-4013 09569-2-4013 09572-2-4013 09576-2-4013 09588-2-4013 Subject to alternations 085 (1) 097 (1) 108 120 133 140 / 146 160 1 92,0 63,4 84,0 6,0 3x4,2 0,80 6,8 — 1 116,0 80,0 108,0 10,0 3x4,5 0,80 10,0 — 1 129,0 87,0 118,0 13,0 4x4,5 1,00 8,0 — 1 142,0 100,0 132,0 9,0 4x4,5 1,00 8,0 — 1 150,0 112,0 142,0 12,0 4x4,5 1,00 10,0 — 1 170,0 125,5 158,0 14,0 4x4,5 1,25 10,0 — 1 (2) 185,0 130,0 175,0 17,0 4x4,5 0,75 12,0 — (1) 3 drilled holes staggered by 120° (2) only for 09588-2-4013 249 AC centrifugal fans Accessories Representatives Inlet nozzles / Air filter for centrifugal fans Vers. 1 Vers. 2 – Material: Galvanised sheet steel Inlet nozzles without measuring device for backward curved centrifugal fans Part no. Size Vers. Dimensions 09576-2-4013 09609-2-4013 96358-2-4013 96359-2-4013 28000-2-4013 31000-2-4013 Subject to alternations 190 1 see corresponding product page 220 2 see corresponding product page 225 1 see corresponding product page 250 1 see corresponding product page 280 1 see corresponding product page 310 1 see corresponding product page – Material: Steel wire / sheet steel plate, plastic coated in RAL no. 9005, black – Filter: Viledon filter type R: PSB / 29 OS (according to DIN 24185) Separation capacity: < 86 % Efficiency: < 20 % Dust binding capacity: 650 g/m2 Air filters for centrifugal blowers (with die-cast aluminium housing) Part no. Size a b c d e 95777-1-5171 95778-1-5171 Subject to alternations 108 / 120 140 / 146 / 160 142,0 66,0 83,0 118-132 145,0 185,0 74,0 91,0 158-175 185,0 Spare filter 95779-1-5171 95780-1-5171 250 Information Connection cables – Connection cable with moulded plug connection in varying lengths. – Wire end with core crimp sleeve, core-end sleeve or tin-plated. – Straight or angled plug. – For all fan types with pin 2.8 / 3.0 x 0.5. DC axial fans DC centrifugal fans DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans Plug model LZ120 LZ120-4 LZ120-5 LZ120-6 LZ120-11 LZ120-16 LZ120-18 LZ126 LZ127 LZ130-1 LZ140 L1 (mm) Leads Plug 610 0,5 mm2 G 2 000 0,5 mm2 G 380 0,5 mm2 W 610 0,5 mm2 W 2 000 0,5 mm2 G 800 0,5 mm2 G 4 000 0,5 mm2 G 1 000 0,5 mm2 G 1 600 0,5 mm2 G 610 0,82 mm2 G 610 0,73 mm2 G Connection cable Straight plug (G) Leads end C A B B A B A C B C B Lead colour black/black black/black red/black red/black red/black black/black black/black black/black black/black black/black black/black Receptacle for tabs 2,8 x 0,5 2,8 x 0,5 2,8 x 0,5 2,8 x 0,5 2,8 x 0,5 2,8 x 0,5 2,8 x 0,5 2,8 x 0,5 2,8 x 0,5 2,8 x 0,5 2,8 x 0,8 Application AC AC DC DC DC AC AC AC AC AC * AC * UL-approved ±0,2 2 8,5 ±0,1 16,5 15 12 7,5 –0,5 16 8,5±0,1 11 10 4 22,5 31 L1 Connection cable Angled plug (W) 8 6 3,5 –0,25 4 7,5 20+0,5 Cor crimp sleeve L1 Leads end A Tin-plated Leads end B 5,5 –0,25 8 Core end sleeve Leads end C »Ø1,5 »Ø1,5 10+5 –2 6 6 251 AC centrifugal fans Accessories Representatives Connection leads (ESM) / Handheld Programmer – Design: Cable conforms to UL standards, sealed plug. Custom-built connection leads on request. Hose line, inner wire (UL Style 2464/1061) 3 x AWG20 (approx. 0.5 mm2) Lead tips Connection leads for energy-saving motors 115/230 VAC Part no. a 13060-4-1040 13061-4-1040 Subject to alternations 450 1500 – Easy speed programming – Battery operated – User-friendly navigation menu – Protective boot with kickstand For Energy Saving Motor (ESM) based products Part no. CBC 000-AF08-01 Subject to alternations Makes quick work of programming the two ESM selectable operating speeds. Eliminates the need for a personal computer, software, power adapter and 2nd cable. Good for production line or field service use. Automatic shut-off function for an extended battery life. Mini-USB connector for uploading software upgrades. Batteries, programming cable and operating manual included. 252 Information Accessories In addition to the accessories and assembly parts listed in this catalogue, ebm-papst also supplies numerous special parts for fans. The sales experts at ebm-papst will be happy to assist you in your enquiries concerning fan assembly and application. DC axial fans DC centrifugal fans DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans Fan series 8300 8400 N 3300 3400 N 9000 4000 4300 8300 Accessories LZ212 / LZ260 LZ261 LZ212 / LZ260 LZ261 LZ210 LZ210 LZ212 / LZ260 LZ212 LZ212 Fan series 5100 5600 5200 5900 7000 VARIOFAN Accessories LZ210 LZ210 LZ210 LZ210 LZ210 LZ370 LZ260 / LZ261 LZ210 Screw clip of stainless steel. For mounting fans with threaded pin 3.5 DIN EN ISO 1478 (7970). LZ370 Temperature sensor for speed-controlled fan operation. Temperature range 30...50 °C. Ø 11 Ø 6,6 (2x) Ø 4 50° Spacer of fibreglass reinforced plastic. For screw mounting over both fan mounting flanges. Screw clip of hardened steel. For mounting fans with threaded pin 6-32 UNC and/or 3.5 DIN 7970. LZ550 (2x) 0,5x45° 0,5 12 6,9 ±0,1 11±0,3 Rubber anti-vibration mounts for fans with a hole ø of 4.3 ±0.2 mm and flange thickness of 3 - 5.5 mm. For a carrier plate with a hole ø of 6.5 ±0.15 mm and plate thickness of 1 - 2 mm. 253 AC centrifugal fans Accessories Representatives Electrical connections EC E) Technical features (Nominal voltage 24 / 48 VDC): • Control input 0-10 VDC / PWM • Tach output • Reverse polarity and locked-rotor protection • Motor current limitation • Voltage-dependent derating • Over-temperature protected electronics / motor • Soft start Notes on various control possibilities and their applications 33 K 4.7 K PWM U 10 K 12 V 12 V Counter Controller Alarm Speed display Maximum ripple ± 3.5% red Lin/PWM control input 0-10 VDC / PWM yellow Tach output pulses per revolution white Temperature control module 50002-1-0174 50003-1-0174 Speed setting PWM 1 - 50 kHz Speed setting with potentiometer Full speed Speed setting 1 V - 10 V 100% PWM -> n=max approx. 10% PWM -> n= min < 10% PWM -> n=0 safe start-up at UNom - 30% as of 40% PWM Customer circuit 10 V -> n=max approx. 1 V -> n=min < 1 V -> n=0 safe start-up at UNom - 30% as of 4V Ucontr. Line 1 GND blue Connection RE > 100 K Isink max. 10 mA 680 Ω 47 V Fan + GND Tacho 0-10 V PWM red blue white yellow Line Connection Colour Assignment / function 1 + red Maximum ripple ± 3.5 % GND blue GND Line Connection Colour Assignment / function 1 Tacho white Tach output 0-10 V / PWM yellow Control input 254 Information DC axial fans DC centrifugal fans DC fans - specials Electrical connections EC G) Technical features (Nominal voltage 24 / 48 VDC): • Control input 0-10 VDC / PWM • Tach output • Reverse polarity and locked-rotor protection Notes on various control possibilities and their applications 33 K 4.7 K PWM U 10 K 12 V 12 V Temperature control module 50002-1-0174 50003-1-0174 Speed setting PWM 1 - 10 kHz Speed setting with potentiometer 100% PWM -> n=max approx. 10% PWM -> n= min < 10% PWM -> n= 0 start up at > 14 % Full speed Speed setting 1 V - 10 V 10 V -> n=max approx. 1 V -> n=min < 1 V -> n=0 start up at > 1.4 V Customer circuit Line 1 Counter Controller Alarm Speed display Maximum ripple ± 3.5% red Lin/PWM control input 0-10 VDC / PWM yellow Tach output pulses per revolution white GND blue Connection Isink max. 10 mA 680 Ω 47 V Fan + GND Tacho 0-10 V PWM red blue white yellow Line Connection Colour Assignment / function 1 + red Maximum ripple ± 3.5 % GND blue GND Line Connection Colour Assignment / function 1 Tacho white Tach output: 2 pulses / revolution (M1G045/M1G055) 3 pulses / revolution (M1G074/M1G084) 0-10 V / PWM yellow Control input (Impedance 100 kΩ) ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Representatives 255 Electrical connections EC H3) Technical features (M3G 045 / M3G 055 with 2 Speed stages): • Speed adjustment input (230V) • Over-temperature protected electronics / motor • Motor current limitation • Locked-rotor protection • Soft start Customer circuit CON10 CON70 CON11 CON70 Connection L CON10 N CON11 SL CON70 PE CON12 PE1 Fan AC1 P AC2 N Line CON10 CON11 CON12 CON70 Connection L N PE SL Colour black blue green/yellow brown Assignment / function Power supply 230 VAC, 50 - 60 Hz, see type plate for voltage range Neutral conductor Protective earth Speed selection: switch open = speed 1; switch closed = speed 2 256 Information DC axial fans DC centrifugal fans DC fans - specials Electrical connections EC H4) Technical features (M3G 055 Speed-controlled): • Output 10 VDC max. 1,1 mA • Tach output • Over-temperature protected electronics / motor • Motor current limitation • Soft start • Locked-rotor protection • Control input 0-10 VDC / PWM • Control interface with SELV potential safely disconnected from the mains max. speed Customer circuit + 10V Speed setting 0-10V/PWM 0-10V/PWM 1-10V GND 10V -> n = max 1V -> n = min <1V -> n = 0 Speed setting with PWM 1-10kHz 15V Imax=10mA 0-10V/PWM 12V GND 100% PWM -> n = max 10% PWM -> n = min <10% PWM -> n = 0 Speed setting with potentiometer + 10V 0-10V/PWM 10K GND Connection L L N N PE PE 3.15AT Fan AC1 P AC2 N PE1 + 10V +10V 0-10V/PWM 10V/PWM GND GND Tacho Tacho Imax=1.1mA 1 3 2 4 47k 47k 1μF 3 1 680R 4 2 ZMM47 Connection L N PE +10V/max.1.1mA Tacho 0-10V PWM GND Colour black blue green/yellow red white yellow blue Assignment / function Power supply 230 VAC, 50 - 60 Hz, see type plate for voltage range Neutral conductor Protective earth Voltage output +10 V / 1.1 mA, electrically isolated, not short-circuit-proof Tach output: Open Collector, 1 pulse per revolution, electrically isolated Control input 0 - 10 V or PWM, electrically isolated GND - Connection for control interface ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Representatives 257 Electrical connections EC J5) Technical features (Nominal voltage 24 / 48 VDC): • Control input 0-10 VDC / PWM • Tach output • Reverse polarity and locked-rotor protection • Motor current limitation • Line undervoltage detection • Soft start max. speed Notes on various control possibilities and their applications Speed setting Speed setting with potentiometer 1 2 1-10V 2 4 10V -> n = max 1V -> n = min <1V -> n = 0 safe start-up at Unom -30% as of 4V Ucontr. 1 4.7K 2 10K 4 UN 1 +24/48VDC 0-10VDC 2 DUE 3 680R Speed setting with PWM 1-10kHz Setting of values via temperature controller 1 33K 2 12V 4 100% PWM -> n = max 10% PWM -> n = min <10% PWM -> n = 0 safe start-up at Unom -30% as of 40% PWM 1 P T OUT 2 N 50003-1-0174 4 T<10°C -> n = 0 T>45°C -> n = max Customer circuit GND 4 39V Reverse -polarity protection Connection Fan Line Connection Colour Assignment / function 1 UN +24/48 VDC red Power supply 24/48 VDC, Maximum ripple ± 3,5 % 2 0-10 VDC yellow Control input Re >100 K 3 Tach white Speed monitoring output, 3 pulses / revolution, Isink max. = 10 mA 4 GND blue Reference ground UB RE>100K DUE GND1 258 Information DC axial fans DC centrifugal fans DC fans - specials Electrical connections AC A1) / C2 / J7) A1) Single-phase capacitor motor (1~ 115/230 VAC power line) with TOP wired internally L PE U1 N C U2 Z U1 = blue U2 = black Z = brown = green/yellow TOP C2) Star connection (3~ 400 VAC power line) without TOP PE L1 L2 L3 U1 V1 W1 U2 V2 W2 U1 = black U2 = green V1 = blue V2 = white W1 = brown W2 = yellow = green/yellow J7) Energy-saving motor (ESM) (1~ 115/230 VAC power line) Mains supply voltage L1 black blue N Speed selection L1 or N brown S Energy-saving motor / fan (ESM) S Speed selection off on (L1 or N) n1 n2 ACmaxx / GreenTech EC-Compact fans AC axial fans AC centrifugal fans Accessories Representatives 259 ebm-papst in Germany ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 74673 Mulfingen GERMANY Phone +49 7938 81-0 Fax +49 7938 81-110 info1@de.ebmpapst.com Berlin Dipl.-Ing. (TH) Jens Duchow Händelstraße 7 16341 Panketal GERMANY Phone +49 30 944149-62 Fax +49 30 944149-63 Jens.Duchow@de.ebmpapst.com Bielefeld Dipl.-Ing. (FH) Wolf-Jürgen Weber Niehausweg 13 33739 Bielefeld GERMANY Phone +49 5206 91732-31 Fax +49 5206 91732-35 Wolf-Juergen.Weber@de.ebmpapst.com Dortmund Dipl.-Ing. (FH) Hans-Joachim Pundt Auf den Steinern 3 59519 Möhnesee-Völlinghausen GERMANY Phone +49 2925 800-407 Fax +49 2925 800-408 Hans-Joachim.Pundt@de.ebmpapst.com Frankfurt Dipl.-Ing. Christian Kleffmann Dr.-Hermann-Krause-Straße 23 63452 Hanau GERMANY Phone +49 6181 1898-12 Fax +49 6181 1898-13 Christian.Kleffmann@de.ebmpapst.com Halle Dipl.-Ing. (TU) Michael Hanning Lercheneck 4 06198 Salzatal / OT Lieskau GERMANY Phone +49 345 55124-56 Fax +49 345 55124-57 Michael.Hanning@de.ebmpapst.com Hamburg Breuell & Hilgenfeldt GmbH Ing. Dirk Kahl Elektroingenieur Grützmühlenweg 48 22339 Hamburg GERMANY Phone +49 40 538092-19 Fax +49 40 538092-84 Dirk.Kahl@de.ebmpapst.com ebm-papst St. Georgen GmbH & Co. KG Hermann-Papst-Straße 1 78112 St. Georgen GERMANY Phone +49 7724 81-0 Fax +49 7724 81-1309 info2@de.ebmpapst.com Heilbronn / Heidelberg Dipl.-Ing. Mark Gartner Gehrweg 12 74199 Unterheinriet GERMANY Phone +49 7130 404569-1 Fax +49 7130 404569-2 Mark.Gartner@de.ebmpapst.com Kassel Dipl.-Ing. (FH) Ralph Brück Hoherainstraße 38 35075 Gladenbach GERMANY Phone +49 6462 4071-10 Fax +49 6462 4071-11 Ralph.Brueck@de.ebmpapst.com Koblenz Winfried Schaefer Hinter der Kirch 10 56767 Uersfeld GERMANY Phone +49 2657 16-96 Fax +49 2657 16-76 Winfried.Schaefer@de.ebmpapst.com Munich Dipl.-Wirt.-Ing. (FH) Jens Peter Uhlandstraße 6 74427 Fichtenberg GERMANY Phone +49 7971 260-180 Fax +49 7971 260-221 Jens.Peter@de.ebmpapst.com Nuremberg Dipl.-Wirt.-Ing. (FH) Axel Resch Dr.-August-Koch-Str. 1 91639 Wolframs-Eschenbach GERMANY Phone +49 9875 9783-170 Fax +49 9875 9783-171 Axel.Resch@de.ebmpapst.com Offenburg Dipl.-Ing. (FH) Ralf Braun Hubeneck 21 77704 Oberkirch GERMANY Phone +49 7802 9822-52 Fax +49 7802 9822-53 Ralf.Braun@de.ebmpapst.com Stuttgart Dipl.-Ing. (FH) Rudi Weinmann Hindenburgstraße 100/1 73207 Plochingen GERMANY Phone +49 7153 9289-80 Fax +49 7153 9289-81 Rudi.Weinmann@de.ebmpapst.com ebm-papst Landshut GmbH Hofmark-Aich-Straße 25 84030 Landshut GERMANY Phone +49 871 707-0 Fax +49 871 707-465 info3@de.ebmpapst.com Ulm M.Sc. Reinhard Sommerreißer Am Silbermannpark 10 86161 Augsburg GERMANY Phone +49 821 6610-7023 Fax +49 821 6610-7024 Reinhard.Sommerreisser@de.ebmpapst.com Distributors Burgdorf ETB Electronic Team Beratungs- u. Vertriebs GmbH Wundramweg 1 31303 Burgdorf GERMANY Phone +49 5136 97229-30 Fax +49 5136 97229-39 info@etb-electronic.de www.etb-electronic.de Frankfurt R.E.D. Handelsgesellschaft mbH Gutenbergstraße 3 63110 Rodgau - Jügesheim GERMANY Phone +49 6106 841-0 Fax +49 6106 841-111 info@red-elektromechanik.de www.red-elektromechanik.de Frankfurt / Neu-Isenburg Arrow Central Europe GmbH Frankfurter Straße 211 63263 Neu-Isenburg GERMANY Telefon: +49(0)6102/5030-0 Telefax: +49(0)6102/5030-8455 E-Mail: info@arrowce.com Hamburg Breuell + Hilgenfeldt GmbH Grützmühlenweg 48 22339 Hamburg GERMANY Phone +49 40 538092-20 Fax +49 40 538092-84 info@breuell-hilgenfeldt.de Walter Kluxen GmbH Neuer Höltigbaum 6 20097 Hamburg GERMANY Phone +49 40 237010 Fax +49 40 23701309 260 Fan agent Compact fan agent Motor specialist Motor agent Information ebm-papst in Europe DC axial fans DC centrifugal fans DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans Klausdorf ETB Electronic Team Beratungs- u. Vertriebs GmbH Zossener Straße 27 15838 Klausdorf GERMANY Phone +49 33703 69-0 Fax +49 33703 69-149 info@etb-electronic.de www.etb-electronic.de Munich A. Schweiger GmbH Ohmstraße 1 82054 Sauerlach GERMANY Phone +49 8104 897-0 Fax +49 8104 897-90 info@schweiger-gmbh.de www.schweiger-gmbh.com Multi-Bauelemente-Service Vertrieb von elektr. Bauelementen GmbH Römerstraße 8 85661 Forstinning GERMANY Phone +49 8121 2506-0 Fax +49 8121 2506-200 multi.bauelemente@mbs.to (1 to 5 pieces) North Breuell + Hilgenfeldt GmbH Grützmühlenweg 48 22339 Hamburg GERMANY Phone +49 40 538092-20 Fax +49 40 538092-84 ebmpapst@breuell-hilgenfeldt.de South Scheffel elektrotechnischer Vertrieb GmbH Aischbach 1 70839 Gerlingen GERMANY Phone +49 7156 28357 Fax +49 7156 49425 info@ebmpapst-service.de Europe Austria ebm-papst Motoren & Ventilatoren GmbH Straubingstraße 17 4030 Linz AUSTRIA Phone +43 732 321150-0 Fax +43 732 321150-20 info@at.ebmpapst.com www.ebmpapst.at Avnet Abacus Vienna Schönbrunner Str. 297-307 1120 Vienna AUSTRIA Phone +43 1 86642-0 Fax +43 1 86642-250 wien@avnet-abacus.eu www.avnet-abacus.eu Compex Ges.m.b.H Wurlitzergasse 10/3 1160 Wien AUSTRIA Phone +43 1 4804223 Fax +43 1 4864230 compex.wien@utanet.at Belarus ebm-papst Bel AgmbH Lipkovskaya Gasse 34 Office No. 6, Room 106, 107 223010 Minsk BELARUS Phone +375 17 3851556 Fax +375 17 3851556 info@by.ebmpapst.com www.ebmpapst.by Belgium ebm-papst Benelux B.V. Sales office Belgium-Luxemburg Romeinsestraat 6/0101 Research Park Haasrode 3001 Heverlee-Leuven BELGIUM Phone +32 16 396-200 Fax +32 16 396-220 info@be.ebmpapst.com www.ebmpapst.be Avnet Abacus Diegem Eagle Building Kouterveldstraat 20 1831 Diegem BELGIUM Phone +32 2 7099 167 Fax +32 2 7099 801 diegem@avnet-abacus.eu www.avnet-abacus.eu Bulgaria ebm-papst Romania S.R.L. Str. Tarnavei No. 20 500327 Brasov ROMANIA Phone +40 268 331859 Fax +40 268 312805 dudasludovic@xnet.ro Compex Ges.m.b.H Wurlitzergasse 10/3 1160 Wien AUSTRIA Phone +43 1 4804223 Fax +43 1 4864230 compex.wien@utanet.at Croatia ebm-papst Industries Kft. Ezred u. 2. 1044 Budapest HUNGARY Phone +36 1 8722-190 Fax +36 1 8722-194 office@hu.ebmpapst.com Compex Ges.m.b.H Wurlitzergasse 10/3 1160 Wien AUSTRIA Phone +43 1 4804223 Fax +43 1 4864230 compex.wien@utanet.at Czech Republic / Slovakia ebm-papst CZ s.r.o. Kaštanová 34a 620 00 Brno CZECH REPUBLIC Phone +420 544 502-411 Fax +420 547 232-622 info@ebmpapst.cz www.ebmpapst.cz Denmark ebm-papst Denmark ApS Vallensbækvej 21 2605 Brøndby DENMARK Phone +45 43 631111 Fax +45 43 630505 mail@dk.ebmpapst.com www.ebmpapst.dk Estonia ebm-papst Oy, Eesti Filiaal Kesk tee 13 Aaviku küla, Jüri Tehnopark 75301 Rae Vald, Harjumaa ESTONIA Phone +372 65569-78 Fax +372 65569-79 www.ebmpapst.ee 261 AC centrifugal fans Accessories Representatives ebm-papst in Europe Finland ebm-papst Oy Puistotie 1 02760 Espoo FINLAND Phone +358 9 887022-0 Fax +358 9 887022-13 mailbox@ebmpapst.fi www.ebmpapst.fi France ebm-papst sarl ZI Nord - rue A. Mohler BP 62 67212 Obernai Cedex FRANCE Phone +33 820 326266 Fax +33 3 88673883 info@ebmpapst.fr www.ebmpapst.fr Greece Helcoma Th. Rotas & Co OE Davaki 65 17672 Kallithea-Attiki GREECE Phone +30 210 9513-705 Fax +30 210 9513-490 contact@helcoma.gr www.helcoma.gr Assimacopoulos S.A. 11, Karitsi Square 10561 Athen GREECE Phone +30 10 322 1737 Fax +30 10 322 5708 assimac@interagora.gr www.assimacopoulos.gr Hungary ebm-papst Industries Kft. Ezred u. 2. 1044 Budapest HUNGARY Phone +36 1 8722-190 Fax +36 1 8722-194 office@hu.ebmpapst.com Iceland RJ Engineers Stangarhyl 1a 110 Reykjavik ICELAND Phone +354 567 8030 Fax +354 567 8015 rj@rj.is www.rj.is 262 Fan agent Ireland ebm-papst UK Ltd. Chelmsford Business Park Chelmsford Essex CM2 5EZ UNITED KINGDOM Phone +44 1245 468555 Fax +44 1245 466336 sales@uk.ebmpapst.com www.ebmpapst.co.uk Italy ebm-papst Srl Via Cornaggia 108 22076 Mozzate (Co) ITALY Phone +39 0331 836201 Fax +39 0331 821510 info@it.ebmpapst.com www.ebmpapst.it Macedonia ebm-papst Industries Kft. Ezred u. 2. 1044 Budapest HUNGARY Phone +36 1 8722-190 Fax +36 1 8722-194 office@hu.ebmpapst.com Netherlands ebm-papst Benelux B.V. Engelseweg 127 5705 AC Helmond NETHERLANDS Phone +31 492 502-900 Fax +31 492 502-950 verkoop@nl.ebmpapst.com www.ebmpapst.nl Avnet Abacus Netherlands Takkebijsters 2 4817 BL Breda NETHERLANDS Phone +31 765 722 300 Fax +31 765 722 303 breda@avnet-abacus.eu www.avnet-abacus.eu Norway ebm-papst AS Nordåsveien 5 1251 Oslo NORWAY Phone +47 22 763340 Fax +47 22 619173 mailbox@ebmpapst.no www.ebmpapst.no Compact fan agent Motor specialist Poland ebm-papst Polska Sp. z o.o. ul. Annopol 4A 03236 Warszawa POLAND Phone +48 22 6757819 Fax +48 22 6769587 office@ebmpapst.pl www.ebmpapst.pl Compex Ges.m.b.H Wurlitzergasse 10/3 1160 Wien AUSTRIA Phone +43 1 4804223 Fax +43 1 4864230 compex.wien@utanet.at Portugal ebm-papst (Portugal), Lda. Centro Empresarial de Alverca Rua de Adarse, Vale D’Ervas Corpo D / Fracção 3 2615-178 Alverca do Ribatejo PORTUGAL Phone +351 218 394 880 Fax +351 218 394 759 info@pt.ebmpapst.com www.ebmpapst.pt Romania ebm-papst Romania S.R.L. Str. Tarnavei Nr. 20 500327 Brasov ROMANIA Phone +40 268 331859 Fax +40 268 312805 dudasludovic@xnet.ro Compex Ges.m.b.H Wurlitzergasse 10/3 1160 Wien AUSTRIA Phone +43 1 4804223 Fax +43 1 4864230 compex.wien@utanet.at Russia ebm-papst Ural GmbH Posadskaja-Strasse, 23(E), 3 620102 Ekaterinburg RUSSIA Phone +7 343 2338000 Fax +7 343 2337788 Konstantin.Molokov@ru.ebmpapst.com www.ebmpapst.ur.ru ebm-papst Rus GmbH proezd 4529, vladenie 5, stroenie 1 141000 Mytistschi, Oblast Moskau RUSSIA Phone +7 495 9807524 Fax +7 495 5140924 info@ebmpapst.ru www.ebmpapst.ru Motor agent Information ebm-papst in Europe and America DC axial fans DC centrifugal fans DC fans - specials ACmaxx / GreenTech EC-Compact fans AC axial fans Serba & Montenegro ebm-papst Industries Kft. Ezred u. 2. 1044 Budapest HUNGARY Phone +36 1 8722-190 Fax +36 1 8722-194 office@hu.ebmpapst.com Spain ebm-papst Ibérica S.L. Avda. del Sistema Solar, 29 28830 San Fernando de Henares (Madrid) SPAIN Phone +34 91 6780894 Fax +34 91 6781530 ventas@ebmpapst.es www.ebmpapst.es Sweden ebm-papst AB Äggelundavägen 2 17562 Järfälla SWEDEN Phone +46 10 4544400 Fax +46 8 362306 info@ebmpapst.se www.ebmpapst.se Switzerland ebm-papst AG Rütisbergstrasse 1 8156 Oberhasli SWITZERLAND Phone +41 44 73220-70 Fax +41 44 73220-77 verkauf@ebmpapst.ch www.ebmpapst.ch Omni Ray AG Im Schörli 5 8600 Dübendorf SWITZERLAND Phone +41 44 802 2880 Fax +41 44 802 2828 r.borner@omniray.ch www.omniray.ch Turkey Akantel Elektronik San. Tic. LTD. Sti. Atatürk Organize Sanayi Bölgesi 10007 SK. No.:6 35620 Cigli-Izmir TURKEY Phone +90 232 3282090 Fax +90 232 3280270 akantel@akantel.com.tr www.ebmpapst.com.tr Ukraine ebm-papst Ukraine LLC Lepse Boulevard, 4, Building 21 03067 Kiev UKRAINE Phone +38 044 2063091 Fax +38 044 2063091 mail@ebmpapst.ua www.ebmpapst.ua United Kingdom ebm-papst UK Ltd. Chelmsford Business Park Chelmsford Essex CM2 5EZ UNITED KINGDOM Phone +44 1245 468555 Fax +44 1245 466336 sales@uk.ebmpapst.com www.ebmpapst.co.uk ebm-papst Automotive & Drives (UK) Ltd. The Smithy Fidlers Lane East Ilsley, Berkshire RG20 7LG UNITED KINGDOM Phone +44 1635 2811-11 Fax +44 1635 2811-61 A&Dsales@uk.ebmpapst.com www.ebmpapst-ad.com America Argentina ebm-papst de Argentina S.A. Hernandarias 148 Lomas del Mirador Pcia. de Buenos Aires (1752) ARGENTINA Phone +54 11 46576135 Fax +54 11 46572092 ventas@ar.ebmpapst.com www.ebmpapst.com.ar Brasil ebm-papst Motores Ventiladores Ltda. Av. José Giorgi, 301 Galpões B6+B7 Condominio Logical Center 06707-100 Cotia - São Paulo BRAZIL Phone +55 11 4613-8700 Fax +55 11 4777-1456 vendas@br.ebmpapst.com www.ebmpapst.com.br Canada ebm-papst Canada Inc. 1800 Ironstone Manor, Unit 2 Pickering, Ontario, L1W3J9 CANADA Phone +1 905 420-3533 Fax +1 905 420-3772 sales@ca.ebmpapst.com www.ebmpapst.ca Mexico ebm Industrial S. de R.L. de C.V. Paseo de Tamarindos 400-A-5to Piso Col. Bosques de las Lomas Mexico 05120, D.F. MEXICO Phone +52 55 3300-5144 Fax +52 55 3300-5243 sales@mx.ebmpapst.com www.ebmpapst.com.mx USA ebm-papst Inc. P.O. Box 4009 100 Hyde Road Farmington, CT 06034 UNITED STATES Phone +1 860 674-1515 Fax +1 860 674-8536 sales@us.ebmpapst.com www.ebmpapst.us ebm-papst Automotive & Drives, Inc. 3200 Greenfield, Suite 255 Dearborn, MI 48120 UNITED STATES Phone +1 313 406-8080 Fax +1 313 406-8081 automotive@us.ebmpapst.com www.ebmpapst-automotive.us 263 AC centrifugal fans Accessories Representatives ebm-papst in Africa, Asia and Australia Africa South Africa ebm-papst South Africa (Pty) Ltd. P.O. Box 3124 1119 Yacht Avenue 2040 Honeydew SOUTH AFRICA Phone +27 11 794-3434 Fax +27 11 794-5020 info@za.ebmpapst.com www.ebmpapst.co.za Asia China ebm-papst Ventilator (Shanghai) Co., Ltd. No. 418, Hua Jing Road Wai Gao Qiao Free Trade Zone No. 2001, Yang Gao (N) Road 200131 Shanghai P.R. of CHINA Phone +86 21 5046-0183 Fax +86 21 5046-1119 sales@cn.ebmpapst.com www.ebmpapst.com.cn Hong Kong ebm-papst Hong Kong Ltd. Room 17E, MG Tower 133 Hoi Bun Road, Kwun Tong Hong Kong P.R. of CHINA Phone +852 2145-8678 Fax +852 2145-7678 info@hk.ebmpapst.com India ebm-papst India Pvt. Ltd. 26/3, G.N.T. Road, Erukkencherry Chennai-600118 INDIA Phone +91 44 25372556 Fax +91 44 25371149 sales@in.ebmpapst.com www.ebmpapst.in Indonesia ebm-papst Indonesia Representative Office German Centre, 4th Floor, Suite 4470 Jl. Kapt. Subijono Dj. Bumi Serpong Damai 15321 Tangerang INDONESIA Phone +62 21 5376250 Fax +62 21 5388305 salesdept@id.ebmpapst.com Israel Polak Bros. Import Agencies Ltd. 9 Hamefalsim Street Kiryat Arie, Petach-Tikva 49514 ISRAEL Phone +972 3 9100300 Fax +972 3 5796679 polak@polak.co.il www.polak.co.il Japan ebm-papst Industries Japan K.K. 12th Floor, Benex S-3 Bldg. 3-20-8 Shinyokohama, Kohoku-ku 222-0033 Yokohama JAPAN Phone +81 45 47057-51 Fax +81 45 47057-52 info@jp.ebmpapst.com www.ebmpapst.jp Korea ebm-papst Korea Co. Ltd. 6F, Trutec Bldg. B 6-2, Digital Media City (DMC) Sangam-Dong, Mapu-Gu Seoul 121-270 KOREA Phone +82 2 366213-24 Fax +82 2 366213-26 info@kr.ebmpapst.com www.ebmpapst.co.kr Malaysia ebm-papst Malaysia Representative Office Unit 12-2, Jalan USJ Sentral 3 Persiaran Subang, Selangor Darul Ehsan 47600 Subang Jaya MALAYSIA Phone +60 3 8024-1680 Fax +60 3 8024-8718 salesdept@my.ebmpapst.com Singapore ebm-papst SEA Pte. Ltd. No. 23 Ubi Road 4 #06-00 Olympia Industrial Building Singapore 408620 SINGAPORE Phone +65 65513789 Fax +65 68428439 salesdept@sg.ebmpapst.com Taiwan ETECO Engineering & Trading Corp. 6F-4, No. 93, Ta-sun 1 St. Road Tsow-Inn District, Kaohsiung TAIWAN Phone +886 7 557-4268 Fax +886 7 557-2788 eteco@ms22.hinet.net www.ebmpapst.com.tw 264 Fan agent Compact fan agent Motor specialist Thailand ebm-papst Thailand Co., Ltd. 99/9 Moo 2, Central Chaengwattana Tower 14th Floor, Room 1402 Chaengwattana Road Bangtarad, Pakkret 11120 Nonthaburi THAILAND Phone +66 2 8353785-7 Fax +66 2 8353788 salesdept@th.ebmpapst.com United Arab Emirates ebm-papst Middle East FZE PO Box 17755 Jebel Ali Free Zone / FZS1 / AP05 Dubai UNITED ARAB EMIRATES Phone +971 4 88608-26 Fax +971 4 88608-27 info@ae.ebmpapst.com www.ebmpapst.ae Vietnam ebm-papst Vietnam Representative Office Room #102, 25 Nguyen Van Thu Street District 1 Ho Chi Minh City 70000 VIETNAM Phone +84 8 39104099 Fax +84 8 39103970 linh.nguyen@vn.ebmpapst.com Australia Australia ebm-papst A&NZ Pty Ltd. 10 Oxford Road Laverton North, Victoria, 3026 AUSTRALIA Phone +61 3 9360-6400 Fax +61 3 9360-6464 sales@ebmpapst.com.au www.ebmpapst.com.au New Zealand ebm-papst A&NZ Pty Ltd. Unit H, 61 Hugo Johnston Drive 1061 Penrose, Auckland NEW ZEALAND PO Box 112278, 1642 Penrose, Auckland Phone +64 9 525-0245 Fax +64 9 525-0246 sales@ebmpapst.com.au www.ebmpapst.com.au Motor agent 265 Representatives Accessories AC centrifugal fans AC axial fans ACmaxx / GreenTech EC-Compact fans DC fans - specials DC centrifugal fans DC axial fans Information Notes 266 Notes 267 www.ebmpapst.com 37634-7-8811 · 2014-03 · RA-4’ Printed in Germany ebm-papst ebm-papst St. Georgen GmbH & Co. KG Mulfingen GmbH & Co. KG ebm-papst Landshut GmbH Hermann-Papst-Straße 1 D-78112 St. Georgen Germany Phone +49 7724 81-0 Fax +49 7724 81-1309 info2@de.ebmpapst.com Bachmühle 2 D-74673 Mulfingen Germany Phone +49 7938 81-0 Fax +49 7938 81-110 info1@de.ebmpapst.com Hofmark-Aich-Straße 25 D-84030 Landshut Germany Phone +49 871 707-0 Fax +49 871 707-465 info3@ de.ebmpapst.com

Top_arrow
回到顶部
EEWORLD下载中心所有资源均来自网友分享,如有侵权,请发送举报邮件到客服邮箱bbs_service@eeworld.com.cn 或通过站内短信息或QQ:273568022联系管理员 高进,我们会尽快处理。