首页资源分类工业控制其他 > Pelton VP Software Nov2011 - Release Notes

Pelton VP Software Nov2011 - Release Notes

已有 453361个资源

下载专区

上传者其他资源

文档信息举报收藏

标    签: PeltonVPSoftware

分    享:

文档简介

适合地震勘探人员阅读

文档预览

Pelton Vib Pro Software November 2011 Install Release Notes November 2011 These release notes describe major improvements, resolved issues, recommendations, and restrictions for Pelton Software. The information in the release notes supersedes and supplements Pelton documentation. IMPORTANT ! Before installing this new software version, please read the instructions concerning computer preparations which must be performed for Windows Vista and Windows 7, and the other installation-related instructions. IMPORTANT ! The Pelton software is not meant to be used in conjunction with older versions of the software (for example, January 2006). The install will detect and remove earlier versions of Pelton software before updating the computer with the new version. Contents What’s New in this Release ............................................................................. 2 Pelton Software Versions.................................................................... 2 Changes and improvements................................................................ 3 Known Issues................................................................................................... 4 Help Files............................................................................................ 4 Stored32 .............................................................................................. 4 Network Security ................................................................................ 4 Upgrading Information .................................................................................... 5 Before You Begin ............................................................................... 5 Windows Installation (XP, 2000)........................................................ 5 Windows 7 Installation ....................................................................... 5 Windows Vista Installation ................................................................. 7 Product Documentation ................................................................................... 8 Pelton Vib Pro Documentation Suite.................................................. 8 Accessing Product Documentation..................................................... 8 Contacting INOVA Customer Service................................................ 8 What’s New in this Release Pelton Software Versions Pelton Software Files Encoder2.exe EncSetup.exe Encoder3.dll Map32.exe ShotPro.exe VpKop32.exe WVSig32.exe 428.dll BM_DLL.dll Com4All.dll ComMgr.exe PRPC 7.x.x PRPC.dll (8.1.x) SercelCMAPP.exe SerHex SpKop.exe Stored32.exe VibQC32 Viewer.exe VPClocks.exe VSSQC.exe Vss2Seg List of program versions and changes: Pelton Software September 2010 file versions Version Date Pelton Software November 2011 file versions Version Date 4.48.00.02 Changed Pelton files 08/31/2010 4.48.00.12 12/29/2011 9.12.00.03 06/24/2010 9.12.00.04 08/23/2011 3.00.00.03 05/12/2010 3.00.00.04 09/24/2010 2.2.0.2 01/11/2010 2.2.0.4 08/23/2011 2.26 08/25/2010 2.28 01/04/2011 2.98.00.05 05/26/2010 2.98.00.11 10/28/2011 2.76 09/23/2011 2.79 10/05/2011 1.4.0.8 1.10 3.06 1.20.00.04 1.41.1.0 1.45.0.0 1.3.1.0 3.1.1.1 1.2.0.3 2.4.0 1.11 2.17.09 1.6 1.13 1.46 Unchanged Pelton files 10/01/2008 1.4.0.8 08/31/2005 1.10 08/04/2010 3.06 09/16/2010 1.20.00.04 04/28/2008 1.41.1.0 11/12/2009 1.45.0.0 07/03/2008 1.3.1.0 06/07/2004 3.1.1.1 10/02/2008 1.2.0.3 01/18/2010 2.4.0 09/28/2010 1.11 09/24/2010 2.17.09 12/17/2002 1.6 04/08/2003 1.13 08/25/2010 1.46 10/01/2008 08/31/2005 08/04/2010 09/16/2010 04/28/2008 11/12/2009 07/03/2008 06/07/2004 10/02/2008 01/18/2010 09/28/2010 09/24/2010 12/17/2002 04/08/2003 08/25/2010 2 Pelton Vib Pro Software November 2011 Release Notes What’s New in this Release Changes and improvements This release of Pelton Software provides improvements, various fixes and changes which fulfill customer requests. These changes are listed in following table. Pelton Software Files Encoder2.exe EncSetup.exe Encoder3.dll Map32.exe ShotPro.exe VpKop32.exe WVSig32.exe Pelton Software September 2010 Pelton Software November 2011 Version Date Version Date Pelton files which were changed 4.48.00.02 8/31/2010 4.48.00.12 12/29/2011 9.12.00.03 6/24/2010 9.12.00.04 08/23/2011 3.00.00.03 05/12/2010 3.00.00.04 09/24/2010 2.2.0.2 1/11/2010 2.2.0.4 08/23/2011 2.26 8/25/2010 2.28 01/04/2011 2.98.00.05 05/26/2010 2.98.00.11 10/28/2011 2.76 09/23/2011 2.79 10/05/2011 Description • VSS recording error notifications allow the program to continue as normal, and logs the errors • Decoder Ready message issue has been corrected. • Enabled Master/Slave start code message with the 428. • Added further support for extended fleets in config files • Added None selection to the alternate ports list in the Slip Sweep tab. • Added more VSS status byte processing in PSS messages. • Added support for Autonomous mode position message • Added increased error handling for RTI data processing. • Corrected Auto Restart delay • When starting manually, the sweep now starts immediately • Corrected PSS display issues • Corrected and updated printer report and added text window for report. • Moved Mass Stroke to Weights menu • Updated help file • Added Average Viscosity and Stiffness to APS report Added error message box when the VSS status is not received. This error message can be disabled. • Changed location of global startup INI file Pelton Vib Pro Software November 2011 Release Notes 3 Known Issues Help Files Stored32 Network Security The help files (with the extension .hlp) are not compatible with or supported by Windows Vista, Windows 7, Windows Server 2008, or Windows Server 2008 R2. The help files were created in Windows Help format, which uses the Help file viewer. Microsoft stopped including the 32-bit Help file viewer in Windows releases beginning with Windows Vista and Windows Server 2008. You can download the Help file viewer from Microsoft at http://support.microsoft.com/kb/917607. Under Windows 7 the Stored32 program has limited access to the PCMCIA flash memory, and can access the memory only when the system is running under the actual administrator account. PCMCIA flash memory cannot be accessed when a user with administrator privileges runs the Stored32 program. Pelton software is designed to be used in the field on a notebook or desktop computer which is not connected to a secure corporate network. When these programs were produced, many of the security features and policies used in today's corporate networks did not exist. For this reason the Pelton software might not be able to be run on a computer which is connected to a secure corporate network. You can use Microsoft’s Windows XP Mode to run the programs on a network. Windows XP Mode is (at the time of these release notes) currently available for free from Microsoft for anyone with a legitimate Windows 7 license. Windows XP Mode constructs a virtual XP computer under Windows 7. You can install the Pelton software in this virtual XP computer and avoid some of the security issues encountered under Windows 7. INOVA Geophysical is continuing to investigate this option. If the Pelton software must be installed in an office environment with a secure network, INOVA recommends that you consult with your I.T. department before installing the Pelton software. If the Pelton software will be used in an office environment, but will not be used to connect with a Vib Pro Encoder or Decoder, it is not necessary to turn off the firewall. 4 Pelton Vib Pro Software November 2011 Release Notes Upgrading Information Upgrading Information Before You Begin Any previous version of Pelton software which exists on the computer must be uninstalled before the new install can be performed. The install program will detect the previous version and will prompt the operator to approve the removal of the previous version of the Pelton software. After the previous version is removed, restart the install, and the new version will be installed on the computer. IMPORTANT ! The uninstall process will only delete those files which were originally installed. Any data or program files which were not part of the install process will not be removed. The current Pelton Install cannot detect installed versions performed on or before December 2003. Windows Installation (XP, 2000) Turn off or disable any firewall which enabled on the computer. It may prevent the new ComMgr from functioning correctly. Windows 7 Installation To install the Pelton Software on Windows 7, follow these instructions: 1. Start the computer and log in as the Windows 7 administrator. 2. Type msconfig as shown in the Run Command dialog: Figure 1. Run Command Dialog Pelton Vib Pro Software November 2011 Release Notes 5 3. In the System Configuration dialog, select the Tools tab and select Change UAC setting. 4. Click Launch. 5. Slide bar all the way to the bottom to select Never Notify and click OK. 6. Restart the system and log in as the Windows 7 administrator. 6 Pelton Vib Pro Software November 2011 Release Notes Upgrading Information 7. Perform the Pelton Install as usual. Windows Vista Installation To install Pelton Software on Windows Vista, use the following instructions: 1. Start the computer and log in as the Vista administrator. 2. In the run command option, type msconfig as shown in Figure 1 on page 5. 3. In the System Configuration dialog, select the Tools tab. 4. In the Tools tab, select Disable UAC, as shown in Figure 2. Figure 2. System Configuration Options 5. Click Launch, then OK. 6. Restart the system and log in as the Vista administrator. 7. Perform the Pelton Install as usual. Pelton Vib Pro Software November 2011 Release Notes 7 Product Documentation Pelton Vib Pro Documentation Suite Accessing Product Documentation Contacting INOVA Customer Service PELTON provides a suite of guides to support you: To learn how to.... Use the Vib Pro Use this guide... VIB PRO Manual P/N 022-000031 Firmware History Vib Pro Firmware History P/N 1018-060002I Operating the Pelton/Sercel 428 Interface Vib Pro Pelton/Sercel 428 Interface Bulletin P/N 1018-060012 All product documentation is delivered with the Pelton software in PDF format on the Pelton Product Software CD (Part Number 025-000064). INOVA Geophysical Corporation provides 24/7 customer support. For help with Pelton, contact Customer Service at: Phone: +1.281.568.2002 Email: customer.support@inovageo.com Website: www.inovageo.com 8 Pelton Vib Pro Software November 2011 Release Notes

Top_arrow
回到顶部
EEWORLD下载中心所有资源均来自网友分享,如有侵权,请发送举报邮件到客服邮箱bbs_service@eeworld.com.cn 或通过站内短信息或QQ:273568022联系管理员 高进,我们会尽快处理。