High accuracy measurements of low-level signals in thepresence of high isolation mode voltages can be difficult dueto the errors of the isolation amplifiers themselves.This error analysis shows that when a low drift operationalamplifier is used to preamplify the low-level source signal,a low cost, simple and accurate solution is possible.In the circuit shown in Figure 1, a 50mV shunt is used tomeasure the current in a 500VDC motor. The OPA27amplifies the 50mV by 200X to 10V full scale. The outputof the OPA27 is fed to the input of the ISO102, which is aunity-gain isolation amplifier. The 5kW and 1kW potentiometersconnected to the ISO102 are used to adjust the gain andoffset errors to zero as described in the ISO102 data sheet.