鼓风机中变频器的节能分析

为了降低燃煤炉鼓风机的用电率、减少起动电流、提高功率因数、改善司炉工工作强度,提出了将变频器用在燃煤炉鼓风机中。与传统的燃煤炉鼓风机系统相比较,该系统利用变频器进行流量(风量)控制时,可节约大量电能。通过详细分析压力H-流量Q曲线,得出变频调速后风机所需功率明显减少。同时,变频器的软启动功能和平滑调速的特点可实现对系统的平稳调节,使系统工作状态稳定,延长锅炉各部件的使用寿命。最后通过实际数据可知使用变频器后的燃煤炉鼓风机是节能的。Abstract:   In  order  to  lower  the  power  consumption  rate  of  coal-fired  furnace  blower,  to  reduce  the  starting  current,  to  increase  the  power  factor,  and  to  improve  the  fireman?蒺s  working  intensity,  frequency  converter  was  proposed  to  be  used  in  coal-fired  furnace  blower.  Compared  to  the  traditional  coal-fired  furnace  blower  system,this  system  used  converter  to  control  the  flow(air  volume),  which  could  save  a  lot  of  power.  Through  a  detailed  analysis  of  the  pressure  H-flow  Q  curve,  it  is  clear  that  after  the  frequency  conversion,  the  required  power  of  blower  is  reduced.  Meanwhile,  the  soft-start  function  of  the  converter  and  the  feature  of  smooth  speed  governing  could  realized  the  smooth  adjustment  of  the  system,which  made  the  system  worked  stable  and  extended  the  service  life  of  various  components  of  the  boiler.  Finally,  the  practice  data  shows  it  is  energy-efficient  to  use  the  frequency  converter  in  coal-fired  furnace  blower.